Carrier 500 T/R user manual General description, Blue, Yellow, Green Edit, Accept, Red Menu, Cncl

Page 4

1 General description

The control panel of the DataCOLD 500 T/R consists of three main components: 1- LCD Display

2- Key board

3- Printer

1.1LCD Display

The display has four lines of information, showing the following content in the operating mode:

Line 1: Alarm active; temperatures, status of the digital inputs

Line 2: Rotating display of each temperature to an accuracy of 1 decimal point with sensor name.

Line 3: Day, date and time and indication summer/wintertime NOTE: Date will be displayed as dd/mm/yyyy (as shown)

Line 4: Description of the actual button functions

In every other mode the content of the display is dependent on the actual menu in use.

1.2Keyboard

-23 –12 –08 –15

1:Return air

–22.8

Wednesday 21/06/2000 13:47:05 W

Print Alarm Menu Status

DataCOLD 500 T/R are completely menu controlled. All functions can be carried out via the four colored buttons (like printing, activate alarms or change parameters). The actual function of the buttons are always displayed on the bottom line. To navigate through the menu’s and change settings, two different kinds of button functions are applicable.

To navigate through the menu’s and to select parameters in the edit mode, use the buttons as described below:

Blue

Next menu point

 

<

In edit mode: Next choice from table

Yellow

Previous menu point

 

>

In edit mode: Previous choice from table

Green

edit

Menu select, change to edit mode or one menu level down

 

accept

In edit mode: accept input and go to next menu point

Red

<-menu

One menu level up

 

<- cncl

In edit mode: Cancel changes and displays the non changed value. Press

 

 

and hold for 2 seconds to cancel changes and go back to previous menu.

When entering free programmable text, like names, the button functions are as follows:

Blue

Next character from the list

Yellow

Previous character from the list

Green

<

One character to the left

Red

>

One character to the right

Blue + Yellow

<- cncl

Cancel changes and displays the non changed value. Press and hold for 2

 

 

seconds to cancel changes and go back to previous menu.

Green + Red

accept

Accept input and go to next menu point.

Page 4

62-61138-20 (02/03)

Image 4
Contents Installation USER’S Manual DataCOLD 500 R DataCOLD 500 TTable of Contents General description BlueYellow Green EditPrinter InstallationPositioning Connections DataCOLD R-Version MountingOptional junction box Optional Mounting kit CON4Power supply ConnectorsDataCOLD T-Version Is not Used for More than TEN 10 Days Alarm outputs WiringConfiguration Display background lighting preferable for the R-VersionFinal testing Standard Installation Temperature sensorsSupplementary installation Alarm signalUser menus Page Day start time Alarm menuDay end time User settings Time settingSummer / wint time setting Date settingDisplay back light setting Keyboard back light settingBuzzer volume setting Buzzer frequency settingMenu 5 Temperature inputs settings Parameter menuT1 Input On/off Return airT3 Input On/off. Menu structure as T4 Input Menu 6 Digital inputs settings Digital inputs setting On/offMenu 7 Compartment settings Compartment On/offMenu Alarm settings Alarm group On/offMenu 9 Printer settings Delivery ticket settingsMenu 10 General settings Temperature units CMenu 11 Communication settings 10.2 Sample rate Minutes11.2 COM2 RS-232 port setting Accessories and spare parts Part Number Designation62-61138-20 02/03 Enclosure a Enclosure B Replace paper roll Enclosure C Factory settings Temperature inputs Factory settingCompartment settings Printer settingsEnclosure D Failure codes & Set correction factor procedure Enter PincodeEnclosure E Wiring diagrams Digital Inputs configuration example= GND = RXD = TXD = CTS