Carrier 500 T/R user manual User settings, Time setting, Summer / wint time setting, Date setting

Page 15

3.3User settings

With the user settings several adjustments can be done to offer the user a maximum of user convenience. By pressing the green button the user setting menu will be activated.

Toggle with [ ], [ ] between the available menu’s (3.1; 3.2; 3.3; …). Between ‘(..)’ the actual setting is displayed. With [edit] you enter the edit mode in order to change the setting to your convenience. The following pictures show the display in the edit mode.

3.3.1Time setting

To set time, press Edit (green button) and the display will show: "ENTER PIN code". The factory setting of the PIN code is 1212.

Select hours, minutes and seconds with [<], [>] and adjust with [], []. Confirm the setting with [accept] (Green-Red).

3.3.2Summer / wint time setting

To set either automatic European daylight savings time adjustment or No adjustment, press Edit (green button) and the display will show: "ENTER PIN code". The factory setting of the PIN code is 1212.

Select Automatic Adjustment or No Adjustment (select No Adjustment for North American use) with [<], [>]. Confirm the setting with [accept] (Green).

3.3.3Date setting

To set date, press Edit (green button) and the display will show: "ENTER PIN code". The factory setting of the PIN code is 1212.

Select date, month and year with [<], [>] and adjust with [], []. Confirm the setting with [accept] (Green-Red).

3.3.4Select language

Select the desired language with [], [] and confirm with [accept].

3.3.5Display contrast setting

Set the desired display contrast [<], [>] and confirm with [accept]. Be aware that at extreme temperatures you might have to adjust the contrast.

Page 15

3.1Time setting (14:09:03)

↑ ↓ edit <-menu

3.1Time setting

ENTER PINCODE

* * * *

1

2

3

4

3.1Time setting 14:09:03

<-cncl accept

↑ ↓ < >

3.2Date setting

ENTER PINCODE

* * * *

1

2

3

4

3.1Time setting 14:09:03

<-cncl accept

↑ ↓ < >

3.2Date setting

ENTER PINCODE

* * * *

1

2

3

4

3.2Date setting 21/06/2002

<-cncl accept

↑ ↓ < >

3.3Select language English

accept <- cncl

3.4Display contrast setting

62-61138-20 (02/03)

Image 15
Contents Installation USER’S Manual DataCOLD 500 T DataCOLD 500 RTable of Contents Green Edit General descriptionBlue YellowInstallation PrinterPositioning Connections Mounting DataCOLD R-VersionOptional junction box CON4 Optional Mounting kitConnectors Power supplyDataCOLD T-Version Is not Used for More than TEN 10 Days Display background lighting preferable for the R-Version Alarm outputsWiring ConfigurationAlarm signal Final testing Standard InstallationTemperature sensors Supplementary installationUser menus Page Alarm menu Day start timeDay end time Date setting User settingsTime setting Summer / wint time settingBuzzer frequency setting Display back light settingKeyboard back light setting Buzzer volume settingReturn air Menu 5 Temperature inputs settingsParameter menu T1 Input On/offT3 Input On/off. Menu structure as T4 Input Compartment On/off Menu 6 Digital inputs settingsDigital inputs setting On/off Menu 7 Compartment settingsDelivery ticket settings Menu Alarm settingsAlarm group On/off Menu 9 Printer settings10.2 Sample rate Minutes Menu 10 General settingsTemperature units C Menu 11 Communication settings11.2 COM2 RS-232 port setting Part Number Designation Accessories and spare parts62-61138-20 02/03 Enclosure a Enclosure B Replace paper roll Printer settings Enclosure C Factory settingsTemperature inputs Factory setting Compartment settingsEnter Pincode Enclosure D Failure codes & Set correction factor procedureDigital Inputs configuration example Enclosure E Wiring diagrams= GND = RXD = TXD = CTS