Carrier 500 T/R Menu 6 Digital inputs settings, Digital inputs setting On/off, Compartment On/off

Page 19

Menu 6 : Digital inputs settings

4 inputs for status recording, any input can be switched on/off, assigned with a name and a polarity. A number of names are available as a factory setting, to be selected from a list.

In the operating mode you can see on the display which inputs are activated. An empty small box indicates the input is active and the status ‘low’. When the status is ‘high’, depending on the assigned function a corresponding symbol is displayed : Refrigeration = , Defrost = , Door contact = , Other = 

6.1

Digital inputs setting

>on/off

If ‘on’ every input status change on D1 will be displayed and recorded with a date/time stamp.

 

6.1.1

Name

>refrigeration

 

Select a sensor name form the list or enter a free text. (Free text is not translated when changing the

 

language.)

 

 

6.1.2

Active on

>high/low

 

Input polarity switch. Switch function if ‘high’: contact closed = input active. If ‘low’: Contact open = input

 

active (applicable for door contacts, active=open).

 

6.1.3

Alarm

>on/off

 

Activates the alarm for this input.

 

 

6.1.4

Delay Time

>10 Minute(s)

 

Alarm delay time in minutes

 

6.2

Digital inp. 2

>on/off, Menu structure as menu 6.1

6.3

Digital inp. 3

>on/off, Menu structure as menu 6.1

6.4

Digital inp. 4

>on/off, Menu structure as menu 6.1

Menu 7 : Compartment settings

In this menu you have to configure the print- and alarm functions for up to maximum 4 compartments. The user is able to print a ticket or activate an alarm per compartment.

7.1

Compartment 1

>on/off

 

De- or activates compartment 1

 

 

 

7.1.1

Compart. Name

>Comp. 1

 

 

The name for a compartment needs to be set as a free text and will not be translated when changing the

 

language.

Assign T1

>on/off

 

 

7.1.2

 

 

7.1.3

Alarm on T1

>on/off

 

 

7.1.4

Assign T2

>on/off

 

 

7.1.5

Alarm on T2

>on/off

 

 

7.1.6

Assign T3

>on/off

 

 

7.1.7

Alarm on T3

>on/off

 

 

7.1.8

Assign T4

>on/off

 

 

7.1.9

Alarm on T4

>on/off

 

 

7.1.10

Print D1

>on/off

 

 

7.1.11

Print D2

>on/off

 

 

7.1.12

Print D3

>on/off

 

 

7.1.13

Print D4

>on/off

 

7.2

Compartment 2

>on/off, Menu structure as menu 7.1

 

7.3

Compartment 3

>on/off, Menu structure as menu 7.1

 

7.4

Compartment 4

>on/off, Menu structure as menu 7.1

 

 

 

 

Page 19

62-61138-20 (02/03)

Image 19
Contents Installation USER’S Manual DataCOLD 500 T DataCOLD 500 RTable of Contents Green Edit General descriptionBlue YellowPrinter InstallationPositioning Connections DataCOLD R-Version MountingOptional junction box CON4 Optional Mounting kitPower supply ConnectorsDataCOLD T-Version Is not Used for More than TEN 10 Days Display background lighting preferable for the R-Version Alarm outputsWiring ConfigurationAlarm signal Final testing Standard InstallationTemperature sensors Supplementary installationUser menus Page Day start time Alarm menuDay end time Date setting User settingsTime setting Summer / wint time settingBuzzer frequency setting Display back light settingKeyboard back light setting Buzzer volume settingReturn air Menu 5 Temperature inputs settingsParameter menu T1 Input On/offT3 Input On/off. Menu structure as T4 Input Compartment On/off Menu 6 Digital inputs settingsDigital inputs setting On/off Menu 7 Compartment settingsDelivery ticket settings Menu Alarm settingsAlarm group On/off Menu 9 Printer settings10.2 Sample rate Minutes Menu 10 General settingsTemperature units C Menu 11 Communication settings11.2 COM2 RS-232 port setting Part Number Designation Accessories and spare parts62-61138-20 02/03 Enclosure a Enclosure B Replace paper roll Printer settings Enclosure C Factory settingsTemperature inputs Factory setting Compartment settingsEnter Pincode Enclosure D Failure codes & Set correction factor procedureDigital Inputs configuration example Enclosure E Wiring diagrams= GND = RXD = TXD = CTS