Pentair 200 Plumbing Connections, Valves, Manual BY-PASS, Below Pool Installation

Page 7

Section III. Installation

7

 

 

 

 

TO

PUMP

 

 

POOL

POOL

 

FILTER

MANUAL

 

HEATER

 

 

BY-PASS

 

 

 

 

 

 

CHECK

GATE

 

 

VALVE

 

 

VALVE

 

 

Figure 2.

 

 

CHECK

 

 

FROM

 

 

 

VALVE

 

 

 

POOL

PLUMBING CONNECTIONS

The MiniMax NT heater has the unique capability of direct schedule 40 PVC plumbing connections. A set of bulkhead fittings is included with the MiniMax NT to insure conformity with Pentair’s recommended PVC plumbing procedure. Other plumbing connections can be used. See Figure 2 for plumbing connections.

CAUTION

Before operating the heater on a new installation, turn on the circulation pump and bleed all the air from the filter using the air relief valve on top of the filter. Water should flow freely through the heater. Do not operate the heater unless water in the pool/spa is at the proper level. If a manual by-pass is installed, temporarily close it to insure that all air is purged from the heater.

VALVES

When any equipment is located below the surface of the pool or spa, valves should be placed in the circulation piping system to isolate the equipment from the pool or spa. Check valves are recommended to prevent back siphoning.

CAUTION

Exercise care when installing chemical feeders so as to not allow back siphoning of chemical into the heater, filters or pump. When chemical feeders are installed in the circulation of the piping system, make sure the feeder outlet line is down stream of the heater, and is equipped with a positive seal noncorrosive “Check Valve”, (P/N R172288), between the feeder and heater.

MANUAL BY-PASS

Where the flow rate exceeds the maximum 120 GPM,

a manual bypass should be installed and adjusted. After adjustments are made, the valve handle should be removed to avoid tampering. See Figure 2.

Model

Min. (GPM)

Max. (GPM) *

 

 

 

 

 

200

20

120

 

 

 

 

 

250

30

120

 

 

 

 

 

300

30

120

 

 

 

 

 

400

40

120

 

 

 

 

 

* Do not exceed the maximum recommended

 

flow rate for the connecting piping.

 

 

 

 

 

 

 

Table 1.

See page 30 for

Pressure Relief Valve Installations.

BELOW POOL INSTALLATION

If the heater is below water level, the pressure switch must be adjusted. This adjustment must be done by a qualified service technician.

See following CAUTION before installation.

CAUTION

BELOW OR ABOVE POOL INSTALLATION

The water pressure switch is set in the factory at 1½ PSI. This setting is for a heater installed at pool level or within 3’ above or 3’ below. If the heater is to be installed more that 3’ above or 3’ below, the water pressure switch must be adjusted by a qualified service technician. See page 22, Figure 22.

FLOW SWITCH

If the heater is installed more the 6’ above the pool or more than 10’ below the pool level, you will be beyond the limits of the pressure switch and a flow switch must be installed. Locate and install the flow switch externally on the outlet piping from the heater, as close as possible to the heater. Connect the flow switch wires in place of the water pressure switch wires.

Rev. G • Rév. G 5-27-04

P/N • Réf. 472090

Image 7
Contents MiniMax NT Pool & Spa Heaters Table of Contents Heater Identification Information HIN Heater Identification InformationImportant Notices Warranty InformationCode Requirements Consumer Information and SafetySpecifications Installation InstructionsManual BY-PASS Below Pool InstallationPlumbing Connections ValvesReversing Headers Water ConnectionsReversible Inlet/Outlet Connection, cont’d GAS Connections GAS Line InstallationsSediment Traps Pipe Sizing for GAS Line Connections GAS Pipe SizingGAS Pressure Requirements Testing GAS PressureIndoor Venting General Requirements Outdoor Shelter Installation Canada Indoor Installation USA onlyVent Adaptors Combustion AIR SupplyFits ALL Models Section Outdoor Vent KIT Outdoor Installation Venting Guidelines Side ViewElectrical Connections Electrical Rating 60 Hz 120 / 240 Volts AC, single phaseVolts AC MiniMax NT TSI/DDTC Wiring Diagram Wiring DIAGRAM-NT STD & TSI with DdtcMinimax NT HSI Electronic Ignition LIGHTING/OPERATION Basic System OperationThermal Fuse Safety ControlsVacuum AIR Pressure FAN Switch Water Pressure SwitchFailure to Light the BURNER-LOCK OUT Heat ModeHigh Limits Operation of Ignition ModuleSystem Indicator Lights Digital Display Temperature Controller DdtcSection IV. Operation SET UP Temperature Setting Troubleshooting Ddtc Troubleshooting InstructionService CHECKS-IGNITION Module Troubleshooting GeneralEnergy Saving Tips Maintenance InstructionWinter Operation Spring and Fall OperationPool and SPA Water Chemical BalanceReplacement Parts NT STD & TSI w/DDTC Réf Rev. G Rév. G Rev. G Rév. G Réf Pentair Pool Products, Inc Chauffe-eau pour piscine et spa MiniMax NT Guide Dinstallation ET DE FonctionnementTable des matières Information Pour Lidentification DU CHAUFFE-EAU Information Pour Lidentification DU CHAUFFE-EAUGarantie Consignes ImportantesConformité AUX Codes Mise EN GardeSpécifications Consignes dinstallationsSoupapes Raccords DE PlomberieDérivation Manuelle Collecteurs réversibles Raccordements DES Conduites DeauRaccords dentrée et de sortie réversibles, suite Raccordement DES Conduites DE GAZ Installations DE LA Conduite DE GAZCollecteurs DE Sédiment Mesure DES Tuyaux Pour Raccords D’ARRIVÉE DE GAZ Dimension DES Tuyaux DE GAZExigences Pour LA Pression DE GAZ Vérification DE LA Pression DE GAZVentilation Intérieur Exigences Générales Installation Intérieure États-Unis Uniquement Adaptateurs Daération Admission Dair DE CombustionConvient À Tous LES Modèles ApprovisionnementdAir Terminaison de la ventilation Ensemble DE Ventilation Pour LextérieurClassement électrique 60 Hz 120/240 Volts c.a. monophasé Raccordements ÉlectriquesVolts CA Réf Rev. G Rév Fonctionnement Générale DU Système Consignes de FonctionnementFusible Thermique Contrôles DE SécuritéCommutateur Ventilateur DE Pression DU Vide Dair Commutateur DE Pression DeauÉchec DE LA Flamme Rallumage Mode ChaleurHautes Limites Verrouillage EN CAS Déchec DallumageTémoins Indicateurs DU Système Thermostat À Affichage NumériqueSection IV. Fonctionnement Réglage DU Thermostat Réglage DE LA Temperature Dépannage Thermostat a Affichage Numerique Consignes DE DépannageVerifications Dentretien Module Dallumage Consignes DE DépannageSoupape DE Surpression Conseils Pour Économies DénergieFonctionnement EN Hiver Fonctionnement AU Printemps ET EN AutomneEAU DE Piscine ET DE SPA Équilibre Chimique DE LeauFORPour Modèle STD Réf Rev. G Rév. G Rev. G Rév. G Réf Veuillez Concerver CE Guide Dinstruction

200 specifications

The Pentair 200 is a sophisticated pool and spa control system designed to offer unmatched convenience, efficiency, and safety for users looking to enhance their aquatic experience. With cutting-edge technologies and a user-friendly interface, the Pentair 200 stands out as a leading solution in the pool management industry.

One of the main features of the Pentair 200 is its advanced automation capabilities. It allows users to control various aspects of their pool and spa, including lighting, heating, and filtration, all from a single control panel or a mobile app. This automation not only enhances usability but also ensures optimal performance, significantly reducing energy consumption compared to manual systems.

The integration with smart technology is another hallmark of the Pentair 200. Users can access the system remotely using their smartphones or tablets, allowing them to manage their pool settings from anywhere. This feature is particularly beneficial for those who may want to ensure their pool is ready for a gathering or simply wish to make adjustments while away from home.

The Pentair 200 is also designed with safety features in mind. It includes multiple protection mechanisms to prevent overheating and ensure regular operational safety, contributing to peace of mind for pool owners. Moreover, the easy-to-understand interface makes programming the system a breeze, even for those who may not be technologically inclined.

Efficiency is paramount in pool management, and the Pentair 200 excels in this area with energy-efficient technologies. Its variable-speed pump capabilities optimize energy usage depending on the specific needs of the pool, thereby resulting in lower utility bills and a reduced environmental impact.

Another notable characteristic is the system's durability and reliability. Constructed with high-quality materials and backed by Pentair's reputation in the industry, the 200 model is built to withstand various environmental conditions and provide consistent performance over time.

In summary, the Pentair 200 is a cutting-edge pool control system that enhances convenience, safety, and energy efficiency. Its advanced automation and smart technology integration make it a standout choice for modern pool owners. With the ability to manage their aquatic environments effectively and efficiently, users can enjoy their pools and spas with greater peace of mind.