Pentair 200 High Limits, Operation of Ignition Module, Heat Mode, Flame FAILURE-RE-IGNITION

Page 23
Figure 25.
23
Diagnostic LED
1 Flash - Air Flow Fault
2 Flashes - Flame no Call for Heat
3 Flashes - Lock Out
Figure 24.

Section IV. Operation

SAFETY CONTROLS, (cont’d.)

Flame Current

Check Point

HIGH LIMITS

A “High Limit”, is a safety device that opens the electrical circuit and shuts off the heater based on a water temperature set point within the “High Limit Device”. The MiniMax NT series of heaters contains two (2) high limit devices which are located on the main inlet / outlet header, one sensing the inlet water temperature and one sensing the outlet water temperature.

OPERATION OF IGNITION MODULE

The Ignition Module, (see Figure 24), is microprocessor based and operates on 24 VAC supplied by the transformer. The control utilizes a microprocessor to continually and safely

monitor, analyze, and control the proper operation of the gas burners. The module with the presence of the flame sensor, using flame rectification, allows the heater to operate.

1. HEAT MODE

When a call for heat is received from the thermostat supplying 24 volts to the (TH) terminal, the module will check the pressure switch for normally open contact. The combustion blower is then energized and, once the air pressure switch contacts close, the 15-second "pre-purge" period begins. After pre-purge, the hot surface igniter is energized for approximately 40-second heat-up period, followed by the gas valve for the "trial for ignition" (TFI) period, for maximum of 7 seconds for the STD model and 6 seconds for the TSI model.

When the flame is detected during the TFI period, through the flame sensor, the igniter is deactivated and the gas valve remains energized.

Note: For all TSI heaters: After the pre-purge period the combustion blower slows down to half normal speed during the heat-up and TFI periods and continues thereafter for another 30 seconds at low speed, then return to full speed for the remainder of the heating cycle.

The thermostat, air pressure switch and burner flame are constantly monitored to assure that the system operates properly. When the thermostat is satisfied and the demand for heat ends, the gas valve is immediately de-energized, the module senses the loss of flame signal and initiates the 45-second "post-purge" period before de-energizing the combustion blower.

2. FAILURE TO LIGHT THE BURNER—LOCK OUT

Should the main burner fail to light, or the flame is not detected during the first TFI (try for ignition) cycle, the gas valve is de-energized and the ignition module performs an "inter-purge" delay (approximately 15 seconds) before attempting another TFI cycle. The module will attempt 2 additional TFI's cycles before locking out. The gas valve will be turned off immediately. The combustion blower will be turned off following 45 seconds "post-purge" period.

The module will automatically reset after one hour, if the thermostat is still calling for heat, and attempt a new TFI cycle.

3. FLAME FAILURE—RE-IGNITION

INTERNAL POWER SWITCH

(Under Control Box)

If the established flame signal is lost while the burner is operating, the control will respond within .08 second. The gas valve is de-energized and

the control starts a new ignition sequence in an attempt to relight the burner. The ignition attempt will be repeated (3) times. If the burner does not relight, the control will go into lockout as previously described in the “Failure to Light the Burner— Lock Out”. If flame is reestablished, normal operation resumes.

Rev. G • Rév. G 5-27-04

P/N • Réf. 472090

Image 23
Contents MiniMax NT Pool & Spa Heaters Table of Contents Heater Identification Information HIN Heater Identification InformationImportant Notices Warranty InformationCode Requirements Consumer Information and SafetySpecifications Installation InstructionsManual BY-PASS Below Pool InstallationPlumbing Connections ValvesReversing Headers Water ConnectionsReversible Inlet/Outlet Connection, cont’d Sediment Traps GAS Line InstallationsGAS Connections Pipe Sizing for GAS Line Connections GAS Pipe SizingGAS Pressure Requirements Testing GAS PressureIndoor Venting General Requirements Outdoor Shelter Installation Canada Indoor Installation USA onlyFits ALL Models Combustion AIR SupplyVent Adaptors Section Outdoor Vent KIT Outdoor Installation Venting Guidelines Side ViewElectrical Connections Electrical Rating 60 Hz 120 / 240 Volts AC, single phaseVolts AC MiniMax NT TSI/DDTC Wiring Diagram Wiring DIAGRAM-NT STD & TSI with DdtcMinimax NT HSI Electronic Ignition LIGHTING/OPERATION Basic System OperationThermal Fuse Safety ControlsVacuum AIR Pressure FAN Switch Water Pressure SwitchFailure to Light the BURNER-LOCK OUT Heat ModeHigh Limits Operation of Ignition ModuleSystem Indicator Lights Digital Display Temperature Controller DdtcSection IV. Operation SET UP Temperature Setting Troubleshooting Ddtc Troubleshooting InstructionService CHECKS-IGNITION Module Troubleshooting GeneralEnergy Saving Tips Maintenance InstructionWinter Operation Spring and Fall OperationPool and SPA Water Chemical BalanceReplacement Parts NT STD & TSI w/DDTC Réf Rev. G Rév. G Rev. G Rév. G Réf Pentair Pool Products, Inc Chauffe-eau pour piscine et spa MiniMax NT Guide Dinstallation ET DE FonctionnementTable des matières Information Pour Lidentification DU CHAUFFE-EAU Information Pour Lidentification DU CHAUFFE-EAUGarantie Consignes ImportantesConformité AUX Codes Mise EN GardeSpécifications Consignes dinstallationsDérivation Manuelle Raccords DE PlomberieSoupapes Collecteurs réversibles Raccordements DES Conduites DeauRaccords dentrée et de sortie réversibles, suite Collecteurs DE Sédiment Installations DE LA Conduite DE GAZRaccordement DES Conduites DE GAZ Mesure DES Tuyaux Pour Raccords D’ARRIVÉE DE GAZ Dimension DES Tuyaux DE GAZExigences Pour LA Pression DE GAZ Vérification DE LA Pression DE GAZVentilation Intérieur Exigences Générales Installation Intérieure États-Unis Uniquement Convient À Tous LES Modèles Admission Dair DE CombustionAdaptateurs Daération ApprovisionnementdAir Terminaison de la ventilation Ensemble DE Ventilation Pour LextérieurClassement électrique 60 Hz 120/240 Volts c.a. monophasé Raccordements ÉlectriquesVolts CA Réf Rev. G Rév Fonctionnement Générale DU Système Consignes de FonctionnementFusible Thermique Contrôles DE SécuritéCommutateur Ventilateur DE Pression DU Vide Dair Commutateur DE Pression DeauÉchec DE LA Flamme Rallumage Mode ChaleurHautes Limites Verrouillage EN CAS Déchec DallumageTémoins Indicateurs DU Système Thermostat À Affichage NumériqueSection IV. Fonctionnement Réglage DU Thermostat Réglage DE LA Temperature Dépannage Thermostat a Affichage Numerique Consignes DE DépannageVerifications Dentretien Module Dallumage Consignes DE DépannageSoupape DE Surpression Conseils Pour Économies DénergieFonctionnement EN Hiver Fonctionnement AU Printemps ET EN AutomneEAU DE Piscine ET DE SPA Équilibre Chimique DE LeauFORPour Modèle STD Réf Rev. G Rév. G Rev. G Rév. G Réf Veuillez Concerver CE Guide Dinstruction

200 specifications

The Pentair 200 is a sophisticated pool and spa control system designed to offer unmatched convenience, efficiency, and safety for users looking to enhance their aquatic experience. With cutting-edge technologies and a user-friendly interface, the Pentair 200 stands out as a leading solution in the pool management industry.

One of the main features of the Pentair 200 is its advanced automation capabilities. It allows users to control various aspects of their pool and spa, including lighting, heating, and filtration, all from a single control panel or a mobile app. This automation not only enhances usability but also ensures optimal performance, significantly reducing energy consumption compared to manual systems.

The integration with smart technology is another hallmark of the Pentair 200. Users can access the system remotely using their smartphones or tablets, allowing them to manage their pool settings from anywhere. This feature is particularly beneficial for those who may want to ensure their pool is ready for a gathering or simply wish to make adjustments while away from home.

The Pentair 200 is also designed with safety features in mind. It includes multiple protection mechanisms to prevent overheating and ensure regular operational safety, contributing to peace of mind for pool owners. Moreover, the easy-to-understand interface makes programming the system a breeze, even for those who may not be technologically inclined.

Efficiency is paramount in pool management, and the Pentair 200 excels in this area with energy-efficient technologies. Its variable-speed pump capabilities optimize energy usage depending on the specific needs of the pool, thereby resulting in lower utility bills and a reduced environmental impact.

Another notable characteristic is the system's durability and reliability. Constructed with high-quality materials and backed by Pentair's reputation in the industry, the 200 model is built to withstand various environmental conditions and provide consistent performance over time.

In summary, the Pentair 200 is a cutting-edge pool control system that enhances convenience, safety, and energy efficiency. Its advanced automation and smart technology integration make it a standout choice for modern pool owners. With the ability to manage their aquatic environments effectively and efficiently, users can enjoy their pools and spas with greater peace of mind.