Powermate PM0645500 manual Service and Storage, Service Information, Infrequent Service

Page 12

SERVICE AND STORAGE

INFREQUENT SERVICE

If the unit is used infrequently, difficult starting may result. to eliminate hard starting, run the generator at least 30 minutes every month. Also, if the unit will not be used for some time, it is a good idea to drain the fuel from the carburetor and gas tank.

LONG TERM STORAGE

When the generator set is not being operated or is being stored more than one month, follow these instructions:

1.Replenish engine oil to upper level.

2.Drain gasoline from fuel tank, fuel line and carburetor.

3.Pour about one teaspoon of engine oil through the spark plug hole, pull the recoil starter several times and replace the plug. Then pull the starter until you feel the piston is on its compression stroke and leave it in that position.

This closes both the intake and exhaust valves to prevent the inside of the cylinder from rusting.

4.Cover the unit and store in a clean, dry place that is well ventilated away from open flame or sparks.

NOTE: We recommend always using a fuel stabilizer. A fuel stabilizer will minimize the formulation of fuel gum deposits during storage. The fuel stabilizer can be added to the gasoline in the fuel tank, or into the gasoline in a storage container.

SERVICE INFORMATION

CONTACT THE COLEMAN® POWERMATE® PRODUCT SERVICE DEPARTMENT AT 1-800-445-1805

or at

www.powermate.com

to obtain warranty service

information or to order

replacement parts or

accessories.

HOW TO ORDER REPLACEMENT PARTS

Even quality built equipment such as the Coleman® Powermate® electric generator you have purchased, might need occasional replacement parts to maintain it in good condition over the years. To order replacement parts, please give the fol- lowing information:

1.Model No. and Serial No. and all specifications shown on the Model No./Serial No. plate.

2.Part number or numbers as shown in the Parts List section.

3.A brief description of the trouble with the generator.

NOTE: If replacement parts are required for the engine, contact one of the engine manufacturer's service centers.

Powermate Corporation

4970 Airport Road

P. O. Box 6001

Kearney, NE 68848

1-800-445-1805

www.powermate.com

www.powermate.com

 

12

 

Customer Hotline 1-800-445-1805

 

 

 

 

 

Image 12
Contents PM0645500 Page Stop AltoTable of Contents Table DES MatieresIndice Safety and Operation Rules Spark Arrester Determining Total WattageSpark Arresting Muffler Installation Operating VoltageCORD-SET Wiring Before OperationMajor Generator Features 120 V, 20 Ampere Duplex ReceptacleStarting the Unit PRE-START PreparationStarting the Engine Applying LoadMaintenance BREAK-IN ProcedureInspecting the Brushes Exciting the GeneratorService and Storage Service InformationInfrequent Service HOW to Order Replacement PartsLimited Warranty Voire la mort Règles D’OPÉRATION ET DE SécuritéPARE-ÉTINCELLES Détermination DE LA Puissance Totale NécessaireSilencieux PARE-ÉTINCELLES Vérifier LA Tension Cable Dinstallation DE Lappareil Avant DE Mettre EN MarcheMise EN Place DE Lappareil CarburantCaractéristiques Principales DU Groupe Electrogene Témoin de charge en pourcentage % Load Il sagit duneDemarrage DE Lappareil Préparatifs AU DémarrageDémarrage DU Moteur Branchement DES AppareilsEntretien Service Clientele Commande DE Pièces DE RechangeUsage ET Entreposage Usage PEU FréquentGarantie Limitée Reglas DE Seguridad Y DE Funcionamiento SeguridadApagachispas Como Determinar EL Vataje TotalSilenciador Apagachispas Instalacion EL Requerimiento DE VoltajeAntes DE LA Operacion Alambrado DEL Juego DE CordonesCaracteristicas Principales DEL Generador Receptáculo dúplex de 120 voltios, 20 amperesArranque DEL Unidad Preparacion Antes DE ArrancarArranque DEL Motor Como Aplicar UNA CargaMantenimiento Servicio Y Almacenamiento Servicio AL ClienteServicio Poco Frecuente Almacenamiento a Largo PlazoGarantía Limitada Parts Drawing / Schema DES Pièces / Diagrama DE Piezas Parts List / Liste DES Pièces / Lista DE Piezas Part Description Descripción QTYCustomer Hotline Date Date Fecha Action Action Accion Airport Road Box Kearney, NE Fax