Briggs & Stratton PRO8000 owner manual When Adjusting or Making Repairs to Your Generator

Page 4

BSPP Generator

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Combustible debris, such as leaves, grass, brush, ect. can catch fire.

DO NOT touch hot surfaces.

Allow equipment to cool before touching.

Keep at least 2 feet of clearance on all sides of generator for adequate ventilation.

In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator”.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

CAUTION

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or call 1-800-743-4115.

Operate generator only on level surfaces.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

4

Image 4
Contents PRO8000 01934 Safety Rules Table of ContentsEquipment Description When Adding or Draining Fuel When Starting EquipmentWhen Operating Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkAir Cleaner Choke Lever Data Tag Circuit Breakers AC Know Your GeneratorAssembly Carton ContentsCheck Battery / Attach Negative Battery Wire Electric StartWhen Adding Fuel Before Starting the EngineAdd Fuel Add Engine OilUsing the Generator Connecting to a Building’s Electrical SystemOperating Generator System GroundConnecting Electrical Loads Stopping the EngineOperating Automatic Idle Control Do not Overload the GENERATOR. See Don’t Overload GeneratorHow to Use the Battery Charger Charging a BatteryTo recharge 12 Volt batteries, proceed as follows Receptacles Cold Weather Operation120/240 Volt AC, 30 Amp, Locking Receptacle Wire Cord Set Volt AC, 30 Amp Locking ReceptacleVolt AC, 20 Amp, Duplex Receptacle Volt DC, 10 Amp ReceptacleTest Gfci Circuit Breaker Ground Fault ProtectionDuring Generator Use Power Management Dont Overload GeneratorCapacity ExampleSpecifications General Maintenance RecommendationsFuel Valve Maintenance Engine Maintenance Generator MaintenanceBattery Maintenance Generator CleaningStorage Generator StorageTroubleshooting Problem Cause CorrectionSchematic Wiring Diagram Unit Exploded View Description Unit Parts ListParts Not Illustrated ADAPTER, Mounting, Alternator Alternator Exploded View and Parts ListASSY, Holder, Rectifier/Brush BREAKER, Circuit, 20A w/hardware Control Panel Exploded View and Parts ListBREAKER, Circuit, 35A, w/hardware Bspp Generator Consumer Use Years Years or YearSymboles de Danger et Moyens Table DES MatièresDescription DE L Équipement AvertissementLe générateur produit une tension élevée Lors DE Lajout OU DE LA Vidange DU CarburantLors DU Démarrage DE Léquipement Lorsque Léquipement FonctionneLorsque Vous Réglez OU Réparez Votre Générateur Unintentional peut résulter dans feu ou électriqueLors DE Tests Dallumage DU Moteur Connaissez Votre Générateur Installation AssemblageDémarrage Électrique Enlever le générateur de la boiteInstallez le bouchon à essence et essuyez lessence déversée Avant LE Démarrage DU MoteurAjoutez de lhuile à moteur Ajoutez de lessenceUtilisation DE LA Génératrice Utilisation DU GénérateurMise à la terre du système Branchement au système électrique dun édificeBranchement des Charges Électriques Arrêt du MoteurFonctionnement du Contrôle Automatique du Ralenti MarcheRecharge d’une Batterie Comment Utiliser le Chargeur de BatterieExploitation PAR Temps Froid Prises DE CourantPrise à Verrouillage de 120/240 Volts c.a., 30 Ampères VentVolts c.a., 20 Ampères Prise de Courant Double Prise à Verrouillage de 120 Volts c.a., 30 AmpèresPrise de 10 Ampères, 12 Volts c.c Mise à lessai du disjoncteur Gfci Protection contre les fuites de terrePendant le fonctionnement de la génératrice NE PAS Surcharger Générateur CapacitéGestion de la Consommation ExempleRecommandations Générales D’ENTRETIEN SpécificationsEntretien du Moteur Entretien du GénérateurRemisage Dépannage Remarques Garantie Limitée Tabla DE Contenidos Descripción DEL EquipoAdvertencia Instrucciones DE SeguridadPeligro Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Tomacorriente Gfci Dobles de 120 Voltios AC, 20 AmpTomacorriente con Dispositivo de Seguridad de Voltios AC a 30 Amperios, monofásica de 60 HzMontaje Arranque EléctricoPara Retirar el Generador de la Caja Contenido de la CajaAntes DE Darle Arranque AL Motor Agregar Aceite al MotorAgregue Combustible Coloque la generador sobre una superficie niveladaUSO DEL Generador Operando EL Generador PrecauciónTierra del Sistema Conexión al Sistema Eléctrico de un EdificioConexion De Cargas Electricas Parado Del MotorFuncionamiento del Control Automático de Marcha en Vacío No Sobrecargue GENERADOR. Vea No Sobrecargue GeneradorCarga de la Bateria Cómo al Uso el Corcel de BateríaOperación Durante UN Clima Frío Receptáculos Precaución120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Juego de Cable de 4 Alambres 240V 120V Neutro CargadoTomacorrientes de 120 Voltios AC, 30 Amperios Tomacorrientes de 12 Voltios DCVolt AC, 20 Amperios, Receptáculos Dobles Juego de Cable de 3 AlambresCompruebe el Disyuntor Gfci Protección Contra Fallos de Conexión a TierraMientras se Utiliza el Generador No Sobrecargue Generador CapacidadControl de la Energía EjemploEspecificaciones Recomendaciones Generales DE MantenimientoMantenimiento del Motor Mantenimiento del GeneradorAlmacenamiento Problemo Accion Causa Diagnositicos DE AveríasGarantía Limitada