Briggs & Stratton 030242-0 manual Assembly, Unpack Generator, Install Wheel Kit

Page 7

Assembly

Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended fuel and oil.

If you have any problems with the assembly of your generator, please call the generator helpline at (800) 743-4115. If calling for assistance, please have the model, revision, and serial number from the data tag available. See Generator Controls and Features for data tag location.

Unpack Generator

1.Set the carton on a rigid, flat surface.

2.Remove everything from carton except generator.

3.Open carton completely by cutting each corner from top to bottom.

4.Leave generator on carton to install wheel kit.

The generator is supplied with:

Operator’s manual

Battery float charger

Oil bottle

Wheel kit

Install Wheel Kit

NOTE: Wheel kit is not intended for over-the-road use.

You will need the following tools to install these components:

7/16” and 13 mm wrenches

Socket wrench with 7/16” and 13 mm sockets

Pliers

Safety glasses

Install the wheel kit as follows:

1.Tip generator so that engine end is up.

2.Slide axle (A) through both mounting brackets.

3.Place a wheel (B) on each side as shown below.

4.Place a washer (C) on axle and then place an e-ring (D) in axle groove.

CAUTION

E-rings can cause eye injury.

E-rings can spring back and become airborne when installing or removing.

Always wear eye protection when installing/removing e-rings.

5.Install e-ring with pliers, squeezing from top of e-ring to bottom of axle.

6.Repeat steps 4 and 5 to secure second wheel.

7.Tip generator so that engine side is down.

8.Attach the vibration mounts (E) to the support leg (F) with 1/4-20 x 1” capscrews (G) and 1/4-20 lock nuts (H).

9.Remove existing locknut from left unit vibration mount with 13mm wrench. Use same locknut to attach support leg.

10.Attach other side of support leg with a M8 x 20 mm capscrew (J) and M8 lock nut (K).

11.Return generator to normal operating position (resting on wheels and support leg).

 

B

 

C

 

A

H

 

F

J

D

 

E

 

G

K

 

7

Image 7
Contents Operator’s Manual Date Purchased Where to Find UsGenerator EngineTable of Contents Hazard Symbols and Meanings Operator SafetySafety Rules Safety alert symbol is used with a signal wordBroken bones, fractures, bruises, or sprains could result Engine exhaust from this product containsContact with muffler area can result in serious burns When Testing for Engine SparkUnintentional sparking can result in fire or electric shock Unpack Generator AssemblyInstall Wheel Kit Install the wheel kit as followsAdd Engine Oil Attach Negative Battery CableAdd Fuel Special Requirements Connecting to a Building’s Electrical SystemSystem Ground Generator LocationItems Not Shown Features and ControlsUsed to supply electrical power for the operation Volt AC, 20 Amp, Duplex Receptacles May beVolt AC, 20 Amp, Duplex Receptacles Cord Sets and ReceptaclesNema L14-30 120/240 Volt AC, 30 Amp, Locking ReceptacleBattery Float Charger Starting the Engine OperationStopping the Engine Connecting Electrical LoadsMove fuel valve to Off position Wattage Reference Guide Don’t Overload GeneratorMaintenance Schedule MaintenanceGenerator Maintenance Engine Maintenance Battery MaintenanceOil Service Spark Arrester Service Air CleanerService Spark Plug Install spark plug and tighten firmlyAir Cooling System Carburetor AdjustmentCheck Valve Clearance Storage Troubleshooting Owner’s Warranty Responsibilities Emissions Control System WarrantyWarranties Emission Information MaintenanceClaims and Coverage Exclusions Limited Warranty Page Common Service Parts Product Specifications800 Manual del Operario Fecha de compra Dónde encontrarnosGenerador MotorControles y características Resolución de problemas GarantíasSeguridad de operario MontajeSímbolos de peligro y sus significados Seguridad de operarioDescripción del equipo Reglas de seguridadCuando Transporte O Repare EL Equipo Cuando Anada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Pruebe LA Bujía DEL Motor Cuando Ajuste O Haga Reparaciones a SU Máquina GeneradorEl generador se entrega con MontajeDesembalaje del generador Instale el juego de ruedasAgregue combustible Agregar aceite al motorConecte el cable negativo de la batería Requisitos especiales Tierra del sistemaConexión al sistema eléctrico de un edificio Ubicación del generadorAmperios, monofásica de 60 Hz Controles y característicasAmps o mayores Juegos de cordones y enchufes conectoresTomas eléctricas dobles de 120 V CA y 20 a Dispositivo de seguridad de 120/240 V, 30 aCargador de flotación de la batería Encienda el motor OperandoSi el motor no arranca, repita los pasos desde 5 hasta Gire la válvula de combustible blanca hasta la posición Off Conexión de cargas eléctricasParada del motor El motor podría petardear, incendiarse o dañarseControl de la energía No sobrecargar el generadorCapacidad EjemploPlan de mantenimiento MantenimientoMantenimiento del generador Comprobación del nivel de aceite Mantenimiento de la bateríaMantenimiento del motor Aceite Recomendaciones sobre el aceiteServicio del depurador de aire Cambio de aceite del motorServicio del bujía Comprobación de holgura de la válvula Limpie la Pantalla ApagachispasLimpie e inspeccione el apagachispas de la siguiente manera Sistema de refrigeración de aireAlmacenamiento Problemo Causa Accion Resolución de problemasGarantía del sistema de control de emisiones GarantíasResponsabilidades de la garantía del propietario Información sobre emisiones Garantía Limitada Page Servicio común despide Especificaciones del producto