Briggs & Stratton 030242-0 manual Add Engine Oil, Add Fuel, Attach Negative Battery Cable

Page 8

Add Engine Oil

1.Place generator on a flat, level surface.

2.Clean area around oil fill and remove yellow oil fill cap.

NOTE: See the section Oil to review oil recommendations. Verify provided oil bottle is correct viscosity for current ambient temperature.

3.Using oil funnel (optional), slowly pour contents of provided oil bottle into oil fill opening.

NOTICE

Improper treatment of generator can damage it and shorten its life.

DO NOT attempt to crank or start the engine before it has been properly serviced with the recommended oil. This may result in an engine failure.

4.Replace oil fill cap and fully tighten.

Add Fuel

Fuel must meet these requirements:

Clean, fresh, unleaded gasoline.

A minimum of 87 octane/87 AKI (91 RON). High altitude use, see High Altitude.

Gasoline with up to 10% ethanol (gasohol) or up to 15% MTBE (methyl tertiary butyl ether) is acceptable.

NOTICE

Avoid generator damage.

Failure to follow Operator’s Manual for fuel recommendations voids warranty.

DO NOT use unapproved gasoline such as E85.

DO NOT mix oil in gasoline.

DO NOT modify engine to run on alternate fuels.

To protect the fuel system from gum formation, mix in a fuel stabilizer when adding fuel. See Storage. All fuel is not the same. If you experience starting or performance problems after using fuel, switch to a different fuel provider or change brands. This engine is certified to operate on gasoline. The emission control system for this engine is EM (Engine Modifications).

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

If fuel spills, wait until it evaporates before starting engine.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

1.Clean area around fuel fill cap, remove cap.

2.Slowly add unleaded gasoline (A) to fuel tank (B). Be careful not to overfill. Allow about 1.5" (4 cm) of tank space (C) for fuel expansion.

B

C

A

3.Install fuel cap and let any spilled fuel evaporate before starting engine.

High Altitude

At altitudes over 5,000 feet (1524 meters), a minimum

85 octane / 85 AKI (89 RON) gasoline is acceptable. To remain emissions compliant, high altitude adjustment is required. Operation without this adjustment will cause decreased performance, increased fuel consumption, and increased emissions. See an authorized dealer for high altitude adjustment information. Operation of the engine at altitudes below 2,500 feet (762 meters) with the high altitude kit is not recommended.

Attach Negative Battery Cable

Your unit is equipped with electric start capability, but can be started manually. If you choose not to use the electric start feature, you do not need to connect the negative battery cable.

The sealed battery on the generator pre–installed except for the negative (black) battery cable.

To install:

1.Cut off tie wrap securing loose end of negative (black) cable.

2.Remove screw (D), lock washer (E) and flat washer (F) on negative battery terminal.

G

D

F

E

3.Slide lock washer, flat washer and negative battery cable (G) over screw.

4.Reattach screw to negative battery terminal and tighten.

8

BRIGGSandSTRATTON.COM

Image 8
Contents Operator’s Manual Where to Find Us GeneratorEngine Date PurchasedTable of Contents Operator Safety Safety RulesSafety alert symbol is used with a signal word Hazard Symbols and MeaningsEngine exhaust from this product contains Broken bones, fractures, bruises, or sprains could resultUnintentional sparking can result in fire or electric shock When Testing for Engine SparkContact with muffler area can result in serious burns Assembly Install Wheel KitInstall the wheel kit as follows Unpack GeneratorAdd Fuel Attach Negative Battery CableAdd Engine Oil Connecting to a Building’s Electrical System System GroundGenerator Location Special RequirementsFeatures and Controls Used to supply electrical power for the operationVolt AC, 20 Amp, Duplex Receptacles May be Items Not ShownCord Sets and Receptacles Nema L14-30120/240 Volt AC, 30 Amp, Locking Receptacle Volt AC, 20 Amp, Duplex ReceptaclesBattery Float Charger Operation Starting the EngineMove fuel valve to Off position Connecting Electrical LoadsStopping the Engine Don’t Overload Generator Wattage Reference GuideGenerator Maintenance MaintenanceMaintenance Schedule Oil Battery MaintenanceEngine Maintenance Service Air Cleaner Service Spark PlugInstall spark plug and tighten firmly Service Spark ArresterCheck Valve Clearance Carburetor AdjustmentAir Cooling System Storage Troubleshooting Warranties Emissions Control System WarrantyOwner’s Warranty Responsibilities Claims and Coverage Exclusions MaintenanceEmission Information Limited Warranty Page 800 Product SpecificationsCommon Service Parts Manual del Operario Dónde encontrarnos GeneradorMotor Fecha de compraResolución de problemas Garantías Seguridad de operarioMontaje Controles y característicasSeguridad de operario Descripción del equipoReglas de seguridad Símbolos de peligro y sus significadosCuando Anada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Máquina Generador Cuando Pruebe LA Bujía DEL MotorMontaje Desembalaje del generadorInstale el juego de ruedas El generador se entrega conConecte el cable negativo de la batería Agregar aceite al motorAgregue combustible Tierra del sistema Conexión al sistema eléctrico de un edificioUbicación del generador Requisitos especialesControles y características Amperios, monofásica de 60 HzJuegos de cordones y enchufes conectores Tomas eléctricas dobles de 120 V CA y 20 aDispositivo de seguridad de 120/240 V, 30 a Amps o mayoresCargador de flotación de la batería Si el motor no arranca, repita los pasos desde 5 hasta OperandoEncienda el motor Conexión de cargas eléctricas Parada del motorEl motor podría petardear, incendiarse o dañarse Gire la válvula de combustible blanca hasta la posición OffNo sobrecargar el generador CapacidadEjemplo Control de la energíaMantenimiento del generador MantenimientoPlan de mantenimiento Mantenimiento de la batería Mantenimiento del motorAceite Recomendaciones sobre el aceite Comprobación del nivel de aceiteServicio del bujía Cambio de aceite del motorServicio del depurador de aire Limpie la Pantalla Apagachispas Limpie e inspeccione el apagachispas de la siguiente maneraSistema de refrigeración de aire Comprobación de holgura de la válvulaAlmacenamiento Resolución de problemas Problemo Causa AccionResponsabilidades de la garantía del propietario GarantíasGarantía del sistema de control de emisiones Información sobre emisiones Garantía Limitada Page Especificaciones del producto Servicio común despide