Briggs & Stratton 030206 owner manual Dont Overload Generator, Capacity, Power Management, Example

Page 11

5500 Watt Portable Generator

DON'T OVERLOAD GENERATOR

Capacity

4.Plug in and turn on the next load.

5.Again, permit the generator to stabilize.

6.Repeat steps 4 and 5 for each additional load.

NEVER add more loads than the generator capacity.Take special care to consider surge loads in generator capacity, as described above.

You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps:

1.Select the items you will power at the same time.

2.Total the rated (running) watts of these items.This is the amount of power your generator must produce to keep your items running. See Figure 7.

3.Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.

Example:

Tool or Appliance

Rated (Running)

 

Additional Surge

Watts

 

 

(Starting) Watts

 

 

 

Window Air

 

1200

 

 

1800

Conditioner

 

 

 

 

 

Refrigerator

 

800

 

 

1600

Deep Freezer

 

500

 

 

500

Television

 

500

 

 

-

Light (75 Watts)

 

75

 

 

-

 

3075 Total

 

1800 Highest

 

Running Watts

 

Surge Watts

Total Rated (Running) Watts

 

= 3075

 

Highest Additional Surge Watts

= 1800

 

Total Generator Output Required

= 4875

 

Power Management

To prolong the life of your generator and attached devices, it is important to take care when adding electrical loads to your generator.There should be nothing connected to the generator outlets before starting it's engine.The correct and safe way to manage generator power is to sequentially add loads as follows:

1.With nothing connected to the generator, start the engine as described in this manual.

2.Plug in and turn on the first load, preferably the largest load you have.

3.Permit the generator output to stabilize (engine runs smoothly and attached device operates properly.

Figure 7 - Wattage Reference Chart

 

 

Rated*

Additional

 

 

Surge

Tool or Appliance

 

(Running)

 

(Starting)

 

 

Watts

 

 

Watts

 

 

 

Essentials

 

 

 

Light Bulb - 75 watt

75

-

Deep Freezer

500

500

Sump Pump

800

1200

Refrigerator/Freezer - 18 Cu. Ft.

800

1600

Water Well Pump - 1/3 HP

1000

2000

Heating/Cooling

 

 

 

Window AC - 10,000 BTU

1200

1800

Window Fan

300

600

Furnace Fan Blower - 1/2 HP

800

1300

Kitchen

 

 

 

Microwave Oven - 1000 Watt

1000

-

Coffee Maker

1500

-

Electric Stove - Single Element

1500

-

Hot Plate

2500

-

Family Room

 

 

 

DVD/CD Player

100

-

VCR

100

-

Stereo Receiver

450

-

Color Television - 27”

500

-

Personal Computer w/17” monitor

800

-

Other

 

 

 

Security System

180

-

AM/FM Clock Radio

300

-

Garage Door Opener - 1/2 HP

480

520

Electric Water Heater - 40 Gallon

4000

-

DIY/Job Site

 

 

 

Quartz Halogen Work Light

1000

-

Airless Sprayer - 1/3 HP

600

1200

Reciprocating Saw

960

960

Electric Drill - 1/2 HP

1000

1000

Circular Saw - 7 1/4”

1500

1500

Miter Saw - 10”

1800

1800

Table Planer - 6”

1800

1800

Table Saw/Radial Arm Saw - 10”

2000

2000

Air Compressor - 1-1/2 HP

2500

2500

*Wattages listed are approximate only. Check tool or appliance for actual wattage.

11

Image 11
Contents 030206 5500W Equipment Description Table of ContentsSafety Rules When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Remove Generator From Carton AssemblyInstall Wheel Kit Install the Wheel Kit as FollowsAdd Engine Oil When Adding FuelInstall fuel cap and wipe up any spilled fuel Before Starting the EngineGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundStopping the Engine Connecting Electrical LoadsOperating Generator Starting the EngineHot Receptacles120/240 Volt AC, 30 Amp, Locking Receptacle Volt AC, 20 Amp, Duplex ReceptaclesExample Power ManagementDont Overload Generator CapacityGenerator Maintenance SpecificationsGeneral Maintenance Recommendations Engine MaintenanceEngine Storage Other Storage Tips StorageGenerator Storage Problem Cause Correction TroubleshootingLimited Warranty Règles DE Sécurité Symboles de Danger et MoyensVeuillez Conserver CES Instructions Table DES Matières Description DE L ÉquipementLorsque Vous Transportez OU Réparez Léquipement Lors DE Lajout OU DE LA Vidange DU CarburantLors DU Démarrage DE Léquipement Lorsque Léquipement FonctionneLors DE Tests Dallumage DU Moteur Lorsque Vous Réglez OU Réparez Votre GénérateurBouchon de remplissage dhuile Ajoutez de lhuile au Connaissez Votre GénérateurEnlever le générateur de la boite Installe la Roue la TrousseInstallez les roues la trousse comme suit figure AssemblageLors DE Lajout DU Carburant Avant LE Démarrage DU MoteurAjoutez de lhuile à moteur Ajoutez de lessenceBranchement au système électrique dun édifice Emplacement de la GénératriceUtilisation DE LA Génératrice Mise à la terre du systèmeArrêt du Moteur Utilisation DU GénérateurDémarrage du Moteur Branchement des Charges Électriques240V 120V Neutre Prises DE CourantVolts c.a., 20 Ampères Prise de Courant Double Prise à Verrouillage de 120/240 Volts c.a., 30 AmpèresExemple NE PAS Surchargez GénérateurCapacité Gestion de la ConsommationEntretien du Générateur Recommandations Générales D’ENTRETIENSpécifications Entretien du MoteurAutres Idées de Remisage RemisageRemisage du Générateur Remisage du MoteurDépannage Garantie Limitée Advertencia Conserve Estas Instrucciones Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadCuando Transporte O Repare EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Pruebe LA Bujía DEL Motor PrecauciónCuando Ajuste O Haga Reparaciones a SU Generador Amperios, monofásica de 60 Hz Conozca SU GeneradorDisyuntor Basculante Tomacorriente Dobles de 120 Voltios AC, 20 AmpRetire todo el material de empaque, relleno, etc MontajePara Retirar El Generador De La Caja Instale el Juego de RuedasColoque la generador sobre una superficie nivelada Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Agregue CombustibleUbicación del Generador USO DEL GeneradorTierra del Sistema Conexión al Sistema Eléctrico de un EdificioParado Del Motor Operando EL Generador PrecauciónEncienda el Motor Conexion De Cargas ElectricasJuego de Cable de 4 Alambres 240V 120V Neutro Cargado Receptáculos PrecauciónVolt AC, 20 Amp, Receptáculos Dobles 120/240 Voltios AC, 30 Amp, Receptáculo de SeguridadEjemplo No Sobrecargue GeneradorCapacidad Control de la EnergíaMantenimiento del Generador EspecificacionesRecomendaciones Generales DE Mantenimiento Mantenimiento del MotorOtras Sugerencias Para el Almacenando AlmacenamientoAlmacenando el Generador Almacenando el MotorDiagnositicos DE Averías Problemo Accion CausaNotas Garantía Limitada