Briggs & Stratton 030206 owner manual When Adjusting or Making Repairs to Your Generator

Page 4

5500 Watt Portable Generator

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Combustible debris, such as leaves, grass, brush, ect. can catch fire.

DO NOT touch hot surfaces.

Allow equipment to cool before touching.

The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.

Keep at least 3 feet of clearance on all sides of generator for adequate cooling, maintenance and servicing.

In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator”.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

CAUTION

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or call 1-800-743-4115.

Operate generator only on level surfaces.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

4

Image 4
Contents 030206 5500W Safety Rules Table of ContentsEquipment Description When Adding or Draining Fuel When Starting EquipmentWhen Operating Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkKnow Your Generator Assembly Install Wheel KitInstall the Wheel Kit as Follows Remove Generator From CartonWhen Adding Fuel Install fuel cap and wipe up any spilled fuelBefore Starting the Engine Add Engine OilUsing the Generator Connecting to a Building’s Electrical SystemSystem Ground Generator LocationConnecting Electrical Loads Operating GeneratorStarting the Engine Stopping the EngineReceptacles 120/240 Volt AC, 30 Amp, Locking ReceptacleVolt AC, 20 Amp, Duplex Receptacles HotPower Management Dont Overload GeneratorCapacity ExampleSpecifications General Maintenance RecommendationsEngine Maintenance Generator MaintenanceGenerator Storage StorageEngine Storage Other Storage Tips Troubleshooting Problem Cause CorrectionLimited Warranty Symboles de Danger et Moyens Veuillez Conserver CES Instructions Table DES MatièresDescription DE L Équipement Règles DE SécuritéLors DE Lajout OU DE LA Vidange DU Carburant Lors DU Démarrage DE LéquipementLorsque Léquipement Fonctionne Lorsque Vous Transportez OU Réparez LéquipementLorsque Vous Réglez OU Réparez Votre Générateur Lors DE Tests Dallumage DU MoteurConnaissez Votre Générateur Bouchon de remplissage dhuile Ajoutez de lhuile auInstalle la Roue la Trousse Installez les roues la trousse comme suit figureAssemblage Enlever le générateur de la boiteAvant LE Démarrage DU Moteur Ajoutez de lhuile à moteurAjoutez de lessence Lors DE Lajout DU CarburantEmplacement de la Génératrice Utilisation DE LA GénératriceMise à la terre du système Branchement au système électrique dun édificeUtilisation DU Générateur Démarrage du MoteurBranchement des Charges Électriques Arrêt du MoteurPrises DE Courant Volts c.a., 20 Ampères Prise de Courant DoublePrise à Verrouillage de 120/240 Volts c.a., 30 Ampères 240V 120V NeutreNE PAS Surchargez Générateur CapacitéGestion de la Consommation ExempleRecommandations Générales D’ENTRETIEN SpécificationsEntretien du Moteur Entretien du GénérateurRemisage Remisage du GénérateurRemisage du Moteur Autres Idées de RemisageDépannage Garantie Limitée Conserve Estas Instrucciones Tabla DE Contenidos Descripción DEL EquipoReglas DE Seguridad AdvertenciaCuando Añada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Disyuntor BasculanteTomacorriente Dobles de 120 Voltios AC, 20 Amp Amperios, monofásica de 60 HzMontaje Para Retirar El Generador De La CajaInstale el Juego de Ruedas Retire todo el material de empaque, relleno, etcAntes DE Darle Arranque AL Motor Agregar Aceite al MotorAgregue Combustible Coloque la generador sobre una superficie niveladaUSO DEL Generador Tierra del SistemaConexión al Sistema Eléctrico de un Edificio Ubicación del GeneradorOperando EL Generador Precaución Encienda el MotorConexion De Cargas Electricas Parado Del MotorReceptáculos Precaución Volt AC, 20 Amp, Receptáculos Dobles120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Juego de Cable de 4 Alambres 240V 120V Neutro CargadoNo Sobrecargue Generador CapacidadControl de la Energía EjemploEspecificaciones Recomendaciones Generales DE MantenimientoMantenimiento del Motor Mantenimiento del GeneradorAlmacenamiento Almacenando el GeneradorAlmacenando el Motor Otras Sugerencias Para el AlmacenandoProblemo Accion Causa Diagnositicos DE AveríasNotas Garantía Limitada