Electrical Adjustments
nPC Offset adjustment
1.Receive the
2.Set to COMPUTER mode.
3.Enter the service mode.
4.Connect an oscilloscope to test point “TP25R1” (+) and chassis ground
5.Select group no. “3”, item no. “11” and change data value to adjust the waveform “a” (black portion ) to be maximum amplitude.
6.Connect an oscilloscope to test point “TP25G1” (+) and chassis ground
7.Select group no. “3”, item no. “12” and change data value to adjust the waveform “a” (black portion ) to be maximum amplitude.
8.Connect an oscilloscope to test point “TP25B1” (+) and chassis ground
9.Select group no. “3”, item no. “13” and change data value to adjust the waveform “a” (black portion ) to be maximum amplitude.
(a)
Black Level
m12 PC Gain adjustment
1.Receive the
2.Set to COMPUTER mode.
3.Enter the service mode.
4.Connect an oscilloscope to test point “TP25R1” (+) and chassis ground
5.Select group no. “2”, item no. “3” and change data value to adjust waveform “a” to be minimum ampli- tude.
6.Connect an oscilloscope to test point “TP25G1” (+) and chassis ground
7.Select group no. “2”, item no. “4” and change data value to adjust waveform “a” to be minimum ampli- tude.
8.Connect an oscilloscope to test point “TP25B1” (+) and chassis ground
9.Select group no. “2”, item no. “5” and change data value to adjust waveform “a” to be minimum ampli- tude.
White Level
(a)
,AV Gain adjustment
1.Receive the
2.Set to VIDEO mode.
3.Enter the service mode.
4.Connect an oscilloscope to test point “TP25R1” (+) and chassis ground
5.Select group no. “2”, item no. “3” and change data value to adjust waveform “a” to be minimum ampli- tude.
6.Connect an oscilloscope to test point “TP25G1” (+) and chassis ground
7.Select group no. “2”, item no. “4” and change data value to adjust waveform “a” to be minimum ampli- tude.
8.Connect an oscilloscope to test point “TP25B1” (+) and chassis ground
9.Select group no. “2”, item no. “5” and change data value to adjust waveform “a” to be minimum ampli- tude.
White Level
(a)
.Common Center adjustment
1.Receive the 1 dot black & white pattern computer sig- nal.
2.Set to COMPUTER mode.
3.Enter the service mode.
4.Project only green light component to the screen.
5.Select group no. “3”, item no. “8” and change data value to obtain the minimum flicker on the screen.
6.Project only blue light component to the screen.
7.Select group no. “3”, item no. “9” and change data value to obtain the minimum flicker on the screen.
8.Project only red light component to the screen.
9.Select group no. “3”, item no. “10” and change data value to obtain the minimum flicker on the screen.