Hitachi HUS103036FL3800, HUS103036FL3600 Environmental conditions and reliability, Conditions

Page 11

3.2 Environmental conditions and reliability

Table 3.2 Environmental conditions and reliability

 

Item

 

Ultrastar

Ultrastar

 

Ultrastar

Ultrastar

 

 

 

10K300-300

10K300-147

10K300-73

10K300-36

Environmental

 

operating

 

5 to 55°C

 

 

conditions

Temperature

non-operating

 

-40 to 70°C

 

 

 

 

storage/shipping

 

-40 to 70°C

 

 

 

Temperature gradient

 

20°C per hour maximum

 

 

Humidity

operating

 

5 to 90%RH

 

 

 

 

non-operating

 

5 to 90%RH

 

 

 

Wet bulb temperature

29°C maximum (non condensing)

 

Atmosphere

 

No corrosive gas, saline atmosphere

 

 

 

 

or organic-metal compound

 

 

 

 

(Example. organic silicon,organic tin)

 

Altitude

operating

 

-300 to 3,000 m

 

 

 

 

non-operating

 

-300 to 12,000 m

 

 

 

Magnetic field

 

 

400 micro Tesla maximum

 

Shock and

Vibration

operating

 

9.8 m/s2(1.0G) maximum

 

vibration

(see Note 6)

non-operating

 

49 m/s2(5.0G) maximum

 

 

Shock

operating

147 m/s2(15G) maximum

[11ms]

 

(see Note 7)

non-operating

735 m/s2(75G) maximum

[11ms]

 

 

 

2450m/s2(250G) maximum

[2ms]

Acoustic noise

Acoustic noise (see Note 8)

 

3.4 bel average

 

 

Reliability

Data Reliability (see Note 9)

Recoverable error:

10 errors in 1012bits read

 

 

 

Non-recoverable error:

10 errors in 1016bits read

 

Seek error rate (see Note 9)

 

10 errors in 108 seeks

 

(see Note 10)

Life

 

5 years (Surface temperature of HDA is 45°C or less)

 

 

 

Life of the drive does not change in the case that the

 

 

 

drive is used intermittently. (See section 7.6)

 

MTBF (see Note 11)

 

Expected 1,200,000 hours

 

Drawing No. Sheet No. Revision

K6610091

11/43

2005/2/23

Image 11
Contents Hitachi Global Storage Technologies K6610091 2005/2/23 Influence for environment General cautions for safetyHeadline of safety caution Safety cautions for this product Warranty and Limited Liability Table of Contents Page Models FeaturesStandards and Related Documents Description CharacteristicsConditions Environmental conditions and reliabilityVibration test direction Shock test direction Power measurement Operating DC Power Requirement DC power InterfaceStart and Stop time Current transition for +12VPage Cabling layout Wide LVD drive Connecting MethodsPage Scsi Interface Page Scsi Commands Supported Orientations Mounting and HandlingHDA upper surface Spacer PCB parts side 25/43 2005/2/23 Temperature Measurement Points Temperature Limits unit CPrecautions for handling Maintenance Physical interface Interface connectorsInterface cable WIDE, LVD mode Interface cable WIDE, Single-ended modeConnector Layout Wide LVD drive Connector Layout SCA-2 LVD drive Pin assignment Connector Signal Name Contact ConductorPin assignment of Scsi Bus Connector C1 WIDE, LVD mode Diffsens ATN +ATN Pin assignment of Scsi Bus Connector C1 SCA-2, LVD modePin assignment of Option Jumper Connector C3 Wide LVD drive Pin assignment of Auxiliary Connector C4 Wide LVD driveJumper connector layout Wide LVD drive Jumper Socket settingScsi ID Wide LVD Wide LVD Enable Delayed Start Scsi bus Terminator Power Jumper socket Extension connector