Hitachi HUS103073FL3800, HUS103036FL3600, HUS103030FL3800, HUS103036FL3800 K6610091 2005/2/23

Page 2

REVISION CONTROL

Remarks

AD: Addition , CH: Change ,CR: Correction ,DL: Deletion

Rev.

Date

Signature

Page

Description

Remarks

0

2003/8/5

DWN : O,Suzuki

All

First Issuance

 

 

 

CHKD: T,Nakazawa

 

 

 

 

 

APPD: T,Nakazawa

 

 

 

1

2003/12/1

DWN : O,Suzuki

9

It updated to new information

CH

 

9

CHKD: T,Nakazawa

10

Table 3.1 Seek time (average)

CH

 

 

APPD: T,Nakazawa

10

Table 3.1 Power requirement

AD

 

 

 

14

Table 3.3

AD

 

 

 

16

Fig 4.1

AD

2

2004/2/24

DWN : O,Suzuki

All

PRELIMINARY

DL

 

 

CHKD: T,Nakazawa

3

UL1950,CAN/CSA

CR

 

 

APPD: T,Nakazawa

9

RRL mark for Korean EMC

CH

 

 

 

9

UL1950,CAN/CSA

CR

 

 

 

10

Byte/sector (514,522)

AD

 

 

 

10

Byte/sector (1024)

DL

 

 

 

10,14

Note 15 (DC Current Value)

AD

 

 

 

11

Life (See section 7.6)

CR

 

 

 

14

Note 13 (Logical Block Address)

CR

3

2004/2/26

DWN : O,Suzuki

16

Fig4.1

CR

 

 

CHKD: T,Nakazawa

 

 

 

 

 

APPD: T,Nakazawa

 

 

 

4

2004/8/17

DWN : O,Suzuki

10

Note15

CH

 

 

CHKD: T,Nakazawa

14

Note14 (Table3.3)

CR

 

 

APPD: T,Nakazawa

14

Note15

CH

5

2004/9/22

DWN : O,Suzuki

28

8.4.8

DL

 

 

CHKD: T,Nakazawa

 

 

 

 

 

APPD: T,Nakazawa

 

 

 

6

2005/2/23

DWN : H,Takeda

10/14

Note

AD

 

 

CHKD:T,Nakazawa

21

Tagged command queuing

CH

 

 

APPD:T,Nakazawa

 

 

 

Drawing No. Sheet No. Revision

K6610091

2/43

2005/2/23

Image 2
Contents Hitachi Global Storage Technologies K6610091 2005/2/23 Influence for environment General cautions for safetyHeadline of safety caution Safety cautions for this product Warranty and Limited Liability Table of Contents Page Features ModelsStandards and Related Documents Characteristics DescriptionEnvironmental conditions and reliability ConditionsVibration test direction Shock test direction Power measurement Operating DC power Interface DC Power RequirementCurrent transition for +12V Start and Stop timePage Connecting Methods Cabling layout Wide LVD drivePage Scsi Interface Page Scsi Commands Supported Mounting and Handling OrientationsHDA upper surface Spacer PCB parts side 25/43 2005/2/23 Temperature Limits unit C Temperature Measurement PointsPrecautions for handling Maintenance Interface connectors Physical interfaceInterface cable WIDE, Single-ended mode Interface cable WIDE, LVD modeConnector Layout Wide LVD drive Connector Layout SCA-2 LVD drive Connector Signal Name Contact Conductor Pin assignmentPin assignment of Scsi Bus Connector C1 WIDE, LVD mode Diffsens Pin assignment of Scsi Bus Connector C1 SCA-2, LVD mode ATN +ATNPin assignment of Auxiliary Connector C4 Wide LVD drive Pin assignment of Option Jumper Connector C3 Wide LVD driveJumper Socket setting Jumper connector layout Wide LVD driveScsi ID Wide LVD Wide LVD Enable Delayed Start Scsi bus Terminator Power Extension connector Jumper socket