Hitachi HUS103036FL3800, HUS103036FL3600, HUS103030FL3800, HUS103073FL3800 Precautions for handling

Page 27

Caution

8 Precautions for handling

The drive is sensitive to shock, vibration, over voltage, temperature, humidity, corrosive gas, magnetic force and electrostatic discharge.

If these forces contact the electrical or mechanical components (magnetic heads, magnetic disks), the drive will break down, degrade, or storage data will be lost. The following handling guidelines are mandatory.

(1)Handle the drive on the appropriate cushion (for example, anti-static pad with thickness of 10mm or more) to prevent from shock and vibration.

(2)Handle the drive with a wrist band, an anti-static mat, or without direct touch of the hands to the PCB in order to prevent static electricity discharge.

(3)Handle the drive in an environment (Temperature, Moisture, Corrosive gas), which follows the drive specification and prevents unforeseen complications.

8.1Packing

After cleaning the drive, pack it in the following manner to protect it from moisture.

(1)Put the drive in an electro-static shielding bag with desiccant.

(2)Packing materials, i.e. electro-static shielding bag, cardboard box, cushion, etc., should not contain corrosive gas, saline or organic-metal compound. (Example organic silicon, organic tin)

(3)If the package has no damage after unpacking, reserve it for storage or Transportation of the drive.

But 20-unit packing material is suitable for only 20 units packing.

When less than 19 units, it is recommended to use the 5-unit packing material.

5-units packing material covers the quantity from 1 to 5.

8.2Transportation

(1)Pack the drive so as to maintain above-mentioned environmental conditions during transportation. (Refer to section 4.2)

(2)When you take the drive out of the packing case and carry it on a hand truck, lay it on cushioning material (for example, urethane foam cushioning with a thickness of 10mm or more).

8.3Storage

When storing, pack the drive to protect it against moisture. (Refer to section 4.2) In case that storage period becomes long, exchange a desiccant and repack. This operation shall be executed every 3 months. (Recommendation)

Drawing No. Sheet No. Revision

K6610091

27/43

2005/2/23

Image 27
Contents Hitachi Global Storage Technologies K6610091 2005/2/23 General cautions for safety Headline of safety cautionInfluence for environment Safety cautions for this product Warranty and Limited Liability Table of Contents Page Models FeaturesStandards and Related Documents Description CharacteristicsConditions Environmental conditions and reliabilityVibration test direction Shock test direction Power measurement Operating DC Power Requirement DC power InterfaceStart and Stop time Current transition for +12VPage Cabling layout Wide LVD drive Connecting MethodsPage Scsi Interface Page Scsi Commands Supported Orientations Mounting and HandlingHDA upper surface Spacer PCB parts side 25/43 2005/2/23 Temperature Measurement Points Temperature Limits unit CPrecautions for handling Maintenance Physical interface Interface connectorsInterface cable WIDE, LVD mode Interface cable WIDE, Single-ended modeConnector Layout Wide LVD drive Connector Layout SCA-2 LVD drive Pin assignment Connector Signal Name Contact ConductorPin assignment of Scsi Bus Connector C1 WIDE, LVD mode Diffsens ATN +ATN Pin assignment of Scsi Bus Connector C1 SCA-2, LVD modePin assignment of Option Jumper Connector C3 Wide LVD drive Pin assignment of Auxiliary Connector C4 Wide LVD driveJumper connector layout Wide LVD drive Jumper Socket settingScsi ID Wide LVD Wide LVD Enable Delayed Start Scsi bus Terminator Power Jumper socket Extension connector