Hitachi HUS103014FL3600, HUS103036FL3600, HUS103030FL3800, HUS103073FL3800 Shock test direction

Page 13

Note 7. The disk drive orientation for shock test is shown in Figure 4.2.

Figure 3.2 Shock test direction

Test conditions on shock test are as follows.

(1) Operating

147m/s2(15G) (Shock mode: half sine wave 11 ms, Test cycle: 5 times)

(2) Non-operating

735m/s2(75G) (Shock mode: half sine wave 11 ms, Test cycle: 5 times)

2450m/s2(250G) (Shock mode: half sine wave 2 ms, Test cycle: 5 times)

Note 8. Acoustic noise is measured except for the start, stop and seek operations. Note 9. Recoverable error is measured at the nominal condition with voltage,

temperature and default error recovery parameters.

Non-recoverable error is defined at the condition of auto-reallocation enabled. Note 10. The drive should be mounted properly (see section 8).

Note 11. MTBF represents a prediction of performance based upon a large statistical sample calculated in accordance with Hitachi's standard procedures.

Hitachi does not warrant that the predicted MTBF is representative of any particular unit or group of units comprising a customer base. The actual failure rates will vary from unit to unit. Surface temperature of HDA is 50°C or less.

A failure defined by MTBF calculation is any event that requires repair or replacement of HDD.

Note 12. Total idle mode power (W) / Total formatted capacity (GB)

Drawing No. Sheet No. Revision

K6610091

13/43

2005/2/23

Image 13
Contents Hitachi Global Storage Technologies K6610091 2005/2/23 Headline of safety caution General cautions for safetyInfluence for environment Safety cautions for this product Warranty and Limited Liability Table of Contents Page Models FeaturesStandards and Related Documents Description CharacteristicsConditions Environmental conditions and reliabilityVibration test direction Shock test direction Power measurement Operating DC Power Requirement DC power InterfaceStart and Stop time Current transition for +12VPage Cabling layout Wide LVD drive Connecting MethodsPage Scsi Interface Page Scsi Commands Supported Orientations Mounting and HandlingHDA upper surface Spacer PCB parts side 25/43 2005/2/23 Temperature Measurement Points Temperature Limits unit CPrecautions for handling Maintenance Physical interface Interface connectorsInterface cable WIDE, LVD mode Interface cable WIDE, Single-ended modeConnector Layout Wide LVD drive Connector Layout SCA-2 LVD drive Pin assignment Connector Signal Name Contact ConductorPin assignment of Scsi Bus Connector C1 WIDE, LVD mode Diffsens ATN +ATN Pin assignment of Scsi Bus Connector C1 SCA-2, LVD modePin assignment of Option Jumper Connector C3 Wide LVD drive Pin assignment of Auxiliary Connector C4 Wide LVD driveJumper connector layout Wide LVD drive Jumper Socket settingScsi ID Wide LVD Wide LVD Enable Delayed Start Scsi bus Terminator Power Jumper socket Extension connector