Hitachi HUS103030FL3800, HUS103036FL3600, HUS103073FL3800, HUS103036FL3800, HUS103073FL3600

Page 17

4.3.2 Spindle Start Selection

When multiple disk drives are connected to the same power supply and turned on simultaneously, a large current will be required at power up.

In the above case, it is recommended to turn the motors on one by one at intervals in order to minimize 12V line current.

This can be done according to the following 3 jumper pin configurations in the case of NW drive:

1.If Disable Auto Start mode is set (C3:9-10 installed);

(1)Use a spindle start command for each drive, issuing it to the next drive after

receiving the previous drive’s Ready condition.

or

(2)Use the spindle start command for each drive, issuing it at intervals of more than 10 seconds.

2.If Enable Auto Start mode is set (C3:9-10 removed) and Spindle Start at Power On is set (C3:13-14 removed);

Manually power on drives at intervals of more than 10 seconds.

3.If Enable Auto Start mode is set (C3:9-10 removed) and Delayed Start is set (C3:13-14 installed);

Upon power on condition, the drives will automatically spin up in 10 second intervals according to their SCSI ID. (The drive with the lowest SCSI ID will start first.)

In the case that their SCSI ID are more than 7, the drives will automatically spin up in 10 second intervals according to the numbers of (SCSI ID minus 8).

Note 1 The Delayed Start setting and the Auto Start setting can be done by commands from host via SCSI bus connector (C1) in the case of NC drive.

Drawing No. Sheet No. Revision

K6610091

17/43

2005/2/23

Image 17
Contents Hitachi Global Storage Technologies K6610091 2005/2/23 Influence for environment General cautions for safetyHeadline of safety caution Safety cautions for this product Warranty and Limited Liability Table of Contents Page Models FeaturesStandards and Related Documents Description CharacteristicsConditions Environmental conditions and reliabilityVibration test direction Shock test direction Power measurement Operating DC Power Requirement DC power InterfaceStart and Stop time Current transition for +12VPage Cabling layout Wide LVD drive Connecting MethodsPage Scsi Interface Page Scsi Commands Supported Orientations Mounting and HandlingHDA upper surface Spacer PCB parts side 25/43 2005/2/23 Temperature Measurement Points Temperature Limits unit CPrecautions for handling Maintenance Physical interface Interface connectorsInterface cable WIDE, LVD mode Interface cable WIDE, Single-ended modeConnector Layout Wide LVD drive Connector Layout SCA-2 LVD drive Pin assignment Connector Signal Name Contact ConductorPin assignment of Scsi Bus Connector C1 WIDE, LVD mode Diffsens ATN +ATN Pin assignment of Scsi Bus Connector C1 SCA-2, LVD modePin assignment of Option Jumper Connector C3 Wide LVD drive Pin assignment of Auxiliary Connector C4 Wide LVD driveJumper connector layout Wide LVD drive Jumper Socket settingScsi ID Wide LVD Wide LVD Enable Delayed Start Scsi bus Terminator Power Jumper socket Extension connector