Hitachi HUS103014FL3600, HUS103036FL3600, HUS103030FL3800, HUS103073FL3800, HUS103036FL3800

Page 21

(8) Tagged Command Queuing

A maximum of 128 commands can be enqueued to this drive. The drive does not have to connect and disconnect to the host controller even if the SCSI command has been issued successively, so the overhead time of the SCSI bus can be reduced.

(9) S.M.A.R.T. (Self - Monitoring, Analysis and Reporting Technology)

This function helps predict a failure related to the degradation of the disk drive itself. For users seeking to use the drive as long as possible, S.M.A.R.T. can be used to predict when failure might occur. The user can use this information to back-up the data before failure.

The S.M.A.R.T. report is written on the disk at regular intervals that are not based on drive usage.

(10)Automatic Read Reallocation

When an error is detected on reading the data, this function automatically assigns

an alternate sector in place of the defective sector and stores the data on the alternated sector.

(11) Write Cache

The controller can return a completion of a WRITE command with a GOOD status after receiving the data from the host but before writing the data from its buffer to the media.

The Deferred Error function reports an Disk Access Error to the host computer if an error occurs when the data are being stored on the disk medium after the GOOD status was already returned. In this case, any data still in the buffer (not yet written to the media) is not assured.

(12) Log Save

Diagnostic information is written on the disk at regular intervals that are not based on drive usage.

Drawing No. Sheet No. Revision

K6610091

21/43

2005/2/23

Image 21
Contents Hitachi Global Storage Technologies K6610091 2005/2/23 General cautions for safety Headline of safety cautionInfluence for environment Safety cautions for this product Warranty and Limited Liability Table of Contents Page Models FeaturesStandards and Related Documents Description CharacteristicsConditions Environmental conditions and reliabilityVibration test direction Shock test direction Power measurement Operating DC Power Requirement DC power InterfaceStart and Stop time Current transition for +12VPage Cabling layout Wide LVD drive Connecting MethodsPage Scsi Interface Page Scsi Commands Supported Orientations Mounting and HandlingHDA upper surface Spacer PCB parts side 25/43 2005/2/23 Temperature Measurement Points Temperature Limits unit CPrecautions for handling Maintenance Physical interface Interface connectorsInterface cable WIDE, LVD mode Interface cable WIDE, Single-ended modeConnector Layout Wide LVD drive Connector Layout SCA-2 LVD drive Pin assignment Connector Signal Name Contact ConductorPin assignment of Scsi Bus Connector C1 WIDE, LVD mode Diffsens ATN +ATN Pin assignment of Scsi Bus Connector C1 SCA-2, LVD modePin assignment of Option Jumper Connector C3 Wide LVD drive Pin assignment of Auxiliary Connector C4 Wide LVD driveJumper connector layout Wide LVD drive Jumper Socket settingScsi ID Wide LVD Wide LVD Enable Delayed Start Scsi bus Terminator Power Jumper socket Extension connector