Emerson GXT3 230V Load Level Indicators 4 Green, 1 Amber, Battery Level Indicators 5 Green

Page 25

Controls and Indicators

7.3Load Level Indicators (4 Green, 1 Amber)

The load level indicator is composed of five sets of LED bars that illuminate to indicate the relative load on the UPS output in 25% increments (±5%). The load level indicator will illuminate as shown in Figure 11.

The load level indicators display the approximate electrical load placed upon the UPS at all times.

Figure 11 Load level indicators.

0 - 25%

26 - 50%

ON OFF OFF OFF OFF

ON ON OFF OFF OFF

51 - 75%

ON ON ON OFF OFF

76 - 100%

Overload

ON ON ON ON OFF

ON ON ON ON ON

7.4Battery Level Indicators (5 Green)

The battery level indicator is composed of five sets of LED bars that illuminate and flash to indicate the battery capacity level. The Liebert® GXT3battery capacity level is shown in 20% increments (±5%). The battery level indicators will illuminate as shown in Figure 12

The battery level indicators display approximate battery capacity at all times.

The Liebert GXT3 is equipped with automatic and remote battery test features. The default setting is for the automatic test to occur every 14 days (this option is user-configurable) if mains has not been interrupted. Should the battery fail this test, the red Fault indicator LED along with the A and C diagnostic LEDs will illuminate and an alarm will sound (refer to 11.0 - Troubleshooting). The remote test feature functions with Liebert MultiLink® and can remotely initiate the battery test.

Figure 12 Battery level indicators.

 

 

Charging

 

 

0 - 20%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flash

OFF

OFF

OFF

OFF

21 - 40%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

Flash

OFF

OFF

OFF

41 - 60%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

ON

Flash

OFF

OFF

61 - 80%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

ON

ON

Flash

OFF

81 - 100%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

ON

ON

ON

Flash

Fully

 

 

 

 

 

 

 

 

 

 

Charged

 

 

 

 

 

 

ON

ON

ON

ON

ON

Discharging

ON OFF OFF OFF OFF

ON ON OFF OFF OFF

ON ON ON OFF OFF

ON ON ON ON OFF

ON ON ON ON ON

ON ON ON ON ON

19

Image 25
Contents Liebert GXT3 230V,5000VA-UL Listed Page Table of Contents Troubleshooting MaintenanceSpecifications CommunicationFigures Page Important Safety Instructions Information for the Protection of the Environment Glossary of Symbols Introduction Battery Charger Rectifier/Power Factor Correction PFC CircuitInverter System DescriptionDC-to-DC Converter BatteryDynamic Bypass Major Components Main Frame and ElectronicsLiebert GXT3 5000VA Terminal Block Communication Removable Power Distribution Box Internal Battery PacksOuter Surface View Power Distribution Box Quick-Connect WHAT’S Included Installation and Configuration Install the Main CabinetTower UPS Installation Connectors Spacers Support BasesInstalling the Adjustable Rack-Mount Kit-Sold Separately Rack-Mount UPS InstallationOperation and Display Panel Rotated Clockwise 90 Degrees Quantity813mm UPS or batteryDepth Retaining latchUPS or battery cabinet Apply grease External Battery Cabinet InstallationTo remove Connect Input/Output PowerTo install Electrical specifications HardwireTerminal Block ConnectionsDistribution Box Electrical Connections Branch circuit breaker ratingsConfiguration Program Configuration Program FeaturesWhat You Will Need Controls and Indicators ON/Alarm Silence/Manual Battery Test ButtonStandby/Manual Bypass Button Battery Level Indicators 5 Green Load Level Indicators 4 Green, 1 AmberUPS status indicators UPS Status IndicatorsUPS Status Indicator Icon Color Description Initial Startup and Electrical Checks Startup Checklist for the Liebert GXT3Operation Disconnecting Input Power from the Liebert GXT3 Manual Battery TestMaintenance Bypass Put the Liebert GXT3 in Manual BypassRemove Screws IT Power System Connectors IT Power System ConfigurationBattery Mode Shutdown Any Mode ShutdownCommunication Interface Port Dry ContactLow Battery On BatteryLiebert IntelliSlot Communication Cards Repo switch connection diagram Remote Emergency Power OffLiebert MultiLink Maintenance Replacing the Internal Battery PackBattery Replacement Procedures Precautions Battery ChargingChecking UPS Functions Checking UPS StatusTroubleshooting UPS SymptomsIndicators Indicator Diagnosis/Audible alarmAudible alarm description Audible AlarmCondition Alarm Problem Cause Solution Troubleshooting tableIlluminated UPS specifications SpecificationsPower distribution specifications Operating temperature parametersExternal battery cabinet specifications Auto-Learning Battery Run Times Page Is t Ne tTwor k Care