Emerson GXT2-10000RT208 Product Warranty Registration, External battery cabinet specifications

Page 53

Specifications

Table 13 External battery cabinet specifications

Model Number

GXT2-288RTVBATT

 

 

Used w/ UPS Model

Liebert GXT2-10000RT208

 

 

DIMENSIONS, Rack Mount, W x D x H

 

 

Unit (with bezel), in (mm)

16.93 x 25.98 x 7 (430 x 660 x 178); 4U

 

 

Shipping, in (mm)

22.64 x 33.46 x 12.40 (575 x 850 x 315)

 

 

WEIGHT lb (kg)

 

 

 

Unit

41.6 (18.9)

 

 

Shipping

50.6 (23)

 

 

BATTERY PARAMETERS

 

 

 

Type

Valve-regulated, non-spillable, flame retardant, lead acid

 

 

Qty x V x Rating

(2) x 12 x 12V x 9.0 AH

 

 

Battery Manufacturer / Part #

Yuasa / REW 45-12 FR

 

 

Backup Time

See Table 6 - Battery run times

 

 

ENVIRONMENTAL

 

 

 

Operating Temp

+32°F to +104°F (0°C to +40°C)

 

 

Storage Temp

+5°F to +122°F (-15°C to +50°C)

 

 

Relative Humidity

0% to 95%, non-condensing

 

 

Operating Elevation

Up to 10,000 ft. (3000m) at 104°F (40°C) without derating

 

 

Storage Elevation

50,000 ft. (15,000m) maximum

 

 

AGENCY

 

 

 

Safety

UL 1778, c-UL Listed (suitable for computer room applications)

 

 

RFI/EMI

FCC Part 15, Subpart B, Class A

 

 

Transportation

ISTA Procedure 1A

 

 

14.1Product Warranty Registration

To register for warranty protection:

Visit the Quick Links section of our Website at: http://www.liebert.com

Click on Product Warranty Registration and fill in the form.

If you have any questions, please contact us at:

US: 800-222-5877

Outside the US: 614-841-6755

upstech@emersonnetworkpower.com

Contact Liebert Global Services at:

US: 800-LIEBERT (800-543-2378) powertech@emersonnetworkpower.com

47

Image 53
Contents Liebert GXT2-10000RT208 Page Table of Contents Modes of Operation Controls and IndicatorsTroubleshooting MaintenanceSpecifications CommunicationsFigures Important Safety Instructions Page Glossary of Symbols Introduction and System Description Battery Charger Rectifier/Power Factor Correction PFC CircuitInverter System DescriptionStatic Bypass BatteryDC to DC Converter Major Components Internal Battery PackMain Frame and Electronics PD-102 Power Distribution Option PD-103 PD-101 Power Distribution Option with Internal ConnectorWHAT’S Included Installation and Configuration Install the Main CabinetTower UPS Installation Attach Bezels to TopReturn flanges Retaining Latches Front Innermembers members Installing the Adjustable Rack-Mount Kit-Sold SeparatelyQuantity Rack Depth M4 nuts M4 nutsUPS External Battery Cabinet External Battery Cabinet InstallationSupport Base With Spacers for External Battery Cabinets Distribution Module Electrical Connections Connect Input/Output PowerElectrical requirements Input & Output Terminal Block Connections208 or Output to Load See Note 120 208 or Input to UPS See NoteHardwire Terminal Block Cover Add an Output Power Distribution Module-OptionalScrew holes Output Distributionto attach to UPS Cover Plate Liebert GXT2 10000RT208Controls and Indicators horizontal overlay Install the Internal Battery PacksInitial Startup and Electrical Checks Hardwire Input ConnectionsOutput Receptacle Distribution Options Hardwire terminal connectionsWhat You Will Need Liebert GXT2-10000RT208 Configuration Program FeaturesConfiguration Program Establishing Communication Link with Configuration Program-InstallationRead/Confirm UPS Configuration Settings Configuration Program-OperationCancel Without Changing UPS Settings Changing UPS SettingsPartial Rejection Programming Rejected When UPS is OffOn-Screen Reminders Output Voltage UPS TabOutput Voltage Selection Notes N Reverse Detection-120V UPS Models OnlyFrequency Selection Options TabOptions Tab Used With Earlier Liebert GXT2 Models Low Battery Time Warning Battery TabAuto Battery Test Time Battery Cabinets NumberAbout Tab Controls and Indicators ON/Alarm Silence/Battery Test ButtonOFF/Bypass Button Horizontal overlay for rack mountingFault Indicator Red Battery Level Indicators 5 GreenBypass Indicator Amber UPS on Indicator GreenBattery Mode Operation Normal Mode OperationBattery Recharge Operation Modes of OperationCommunications Communications Interface Port11.1.1 DB-9 Interface Port DB-9 pin assignmentUPS Intelligent Communications Pin 4 Remote Shutdown on BatteryCommunications-Liebert SNMP/OCWEBCARD Snmp Adapter Wrap network cable around ferrite beadRepo Connection Remote Emergency Power OffKey to Repo switch connections 1 VDC Sense Common Maintenance Battery ReplacementInternal Battery Replacement Procedures BatteryUPS Power Module Replacement UPS back panel-control location Indicator status Diagnosis/Audible alarm TroubleshootingFault indicators Condition Alarm Alarm conditionsTroubleshooting guide Problem Cause Solution See 12.2 UPS Power Module Replacement Battery/External 10000VA Run Time Cabinets Load% Minutes Battery run timesAuto-Learning Battery Run Times UPS specifications SpecificationsOptional output distribution specifications-PD-101 Battery specificationsSee Battery run times Model Number PD-101 DIMENSIONS, W x D x HOptional output distribution specifications-PD-103 Optional output distribution specifications-PD-102Model Number PD-102 DIMENSIONS, W x D x H Model Number PD-103 DIMENSIONS, W x D x HModel Number Product Warranty RegistrationExternal battery cabinet specifications Specifications Page Iti Ne tTi n That