Emerson 5081-T instruction manual 9241516-01

Page 39

This document contains information proprietary to Rosemount Analytical, and is not to be made available to those who may compete with Rosemount Analytical.

4X R .25

2X FULL R

.140

Ø .125

ROSEMOUNTRANALYTICAL

MODEL

SA R LR34186

5081-T-FI-69

ENCLOSURE 4

Exia ENTITY

INTRINSICALLY SAFE FOR

CLASS I, GRPS A, B, C & D

CLASS II, GRPS E, F & G

CLASS III

T3A Tamb = 70°C

HAZARDOUS AREA WHEN CONNECTED

PER DWG. 1400285

WARNING: COMPONENT SUBSTITUTION

MAY IMPAIR INTRINSIC SAFETY.

CLASS I, DIV. 2, GRPS A,B,C & D SUITABLE FOR

CLASS II, DIV. 2, GRPS E, F & G

T3A Tamb= 70°C

WARNING-EXPLOSION HAZARD-DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON- HAZARDOUS.

WARNING-EXPLOSION HAZARD-SUBSTITU- TION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIV 2.

CLASS I, GRPS B,C & D

CLASS II, GRPS E, F & G

CLASS III

Tamb = 65°C MAX

Tamb ABOVE 60°C USE 75°C MINIMUM

RATED WIRING

SEAL REQUIRED TO BE INSTALLED

WITHIN 50 mm OF THE ENCLOSURE.

KEEP COVER TIGHT WHILE CIRCUITS

ARE LIVE.

9241516-01/A

.125

.650 ±.015

RELEASE DATE

ECO NO

REV

 

 

REVISIONS

 

 

 

LTR

ECO

DESCRIPTION

5-6-04

8925

A

.120 ±.015

2.56 ±.02

2.180 ±.005

BY DATE CHK

THIS DOCUMENT IS

CERTIFIED BY

CSA

REV A

 

REV

 

REV

 

REV

 

REV

 

REV

REVISIONS NOT PERMITTED

MODEL 5081-T

1.30 ±.02

W/O AGENCY APPROVAL

4 FINISH:SILKSCREEN BLACK EPOXY PAINT (BAKED).

3.ARTWORK IS SHEET 2 OF 2.

2.NO CHANGE WITHOUT CSA APPROVAL.

1MATERIAL: AISI 300 SERIES STAINLESS STEEL .015+/-.005 THICK. MATERIAL TO BE ANNEALED & PASSIVATED. MAXIMUM HARDNESS BRINELL 190.

NOTES: UNLESS OTHERWISE SPECIFIED

UNLESS OTHERWISE SPECIFIED

.XX

+

TOLERANCES

 

 

.030

+

1/2

.XXX

-

ANGLES

+

.010

-

 

 

-

 

 

DIMENSIONS ARE IN INCHES

REMOVE BURRS & SHARP EDGES .020 MAX

MACHINED FILLET RADII .020 MAX

NOMINAL SURFACE FINISH 125

MATERIAL

1

FINISH

4

ITEM

PART NO

 

 

DESCRIPTION

QTY

 

 

 

BILL OF MATERIAL

 

 

APPROVALS

DATE

Uniloc

 

Rosemount Analytical,

 

 

 

 

Irvine, CA 92606

 

 

 

 

 

 

Uniloc Division

 

 

 

 

 

 

2400 Barranca Pkwy

DRAWN

B. JOHNSON

5/3/04

TITLE

 

 

 

CHECKED

J. FLOCK

 

 

LABEL, I.S. CSA

5/6/04

 

 

PROJECT

J. FLOCK

5/6/04

 

 

5081-T-FI

 

ENGR APVD

 

DWG NO

REV

THIS DWG CREATED IN

 

SIZE

9241516-01

SOLID EDGE

 

 

 

A

 

 

B

 

 

 

 

 

 

SCALE 2:1

 

SHEET 1 OF 2

SECTION INTRINSICALLY SAFE & EXPLOSION PROOF

33

FIGURE 4-16. CSA Intrisically Safe Label for Model 5081-T-FI

 

4.0

Image 39
Contents Model 5081-T Rev. Level Date Essential InstructionsModel 5081-T Table of Contents CONT’D List of Figures Number TitleIii List of Tables List of Figures CONT’DSimple Menu Structure Section Description and SpecificationsHart Recommended Sensors AtexRecommended Ranges for Toroidal Sensors Transmitter Display During Calibration and Programming I T N E X THart Interface Devices Overview of Hart CommunicationFoundation Fieldbus AMS Main Menu Tools Orienting the Display Board Section InstallationMechanical Installation Unpacking and InspectionMounting on a Flat Surface Pipe Mounting 40308103Recommended Sensors Inductive LoopsSensor Selection Model 5081-T Sensor SelectionModel 5081-T-HT Power SUPPLY/CURRENT LoopPower Supply and Load Requirements. Refer to Figure Power Supply-Current Loop WiringTypical Fieldbus Network Electrical Wiring Configuration Power Supply Wiring for Model 5081-T-FF/FIWiring Through a Junction BOX Section WiringSensor Wiring Electrical Installation Sensor WiringPower Wiring Model 5081-T-FF Power Wiring Model 5081-T-HTWiring Model 242 sensor to Model 5081-T transmitter Electrical InstallationSection Section Section Intrinsically Safe & Explosion Proof IRC Infrared Remote ControlFM Explosion-Proof Installation for Model 5081-T-HT FM Intrinsically Safe Installation for Model 5081-T-HT CSA Intrinsically Safe Installation for Model 5081-T-HT Atex Intrisically Safe Label for Model 5081-T-HT Atex Intrisically Safe Label for Model 5081-T-HT FM Explosion-Proof Installation for Model 5081-T-FF FM Intrinsically Safe Installation for Model 5081-T-FF 10. CSA Intrinsically Safe Installation for Model 5081-T-FF 11. Atex Intrisically Safe Label for Model 5081-T-FF 12. Atex Intrinsically Safe Installation for Model 5081-T-FF FI-T 9241515-01 15. FM Intrinsically Safe Installation for Model 5081-T-FI 9241516-01 17. CSA Intrinsically Safe Installation for Model 5081-T-FI 18. Atex Intrisically Safe Label for Model 5081-T-FI 19. Atex Intrinsically Safe Installation for Model 5081-T-FI I T N E X T Section Display and OperationDisplays S UInfrared Remote Controller Infrared Remote Controller IRC KEY FunctionsQuick Start for Model 5081-T-HT Hart To reset transmiter to factory default settingsQuick Start for Model 5081-T-FF/FI Foundation Fieldbus Calibration Program Menu Tree Conductivity25.0C 12.00mA Process DisplayProgram Menu Mnemonics Default Settings Diagnostic MessagesDefault Settings for Model 5081-T-HT Retrieving a Lost Security Code Using HoldSecurity Entering the Security CodeSection START-UP and Calibration Accessing the Calibrate MenuModel 5081-T-FF Calibrate MenuOutput Cal Procedure9URU Temp SlopeU91 5ES-U1U17!91 GM!91Section Programing GeneralModel 5081-T-HT Model 5081-T-FF Output 5081-HT only PurposeDefinitions Uhtu Procedure9VUVU 4QGProcess temperature is. Press Enter to save TempU7-P H2SO4L DisplayG5-A HCLGgshtt Hart8VO!UT Setup CustPVO!RUT!!% SHIG12-U DefaultSetting Measurement Range Over Range Warning Limit RangePID Section Foundation Fieldbus OperationSection Operation with Model Connecting the CommunicatorMaking Hart related settings from the keypad OperationOff-line and On-line Operation C/T-HT HART/Model 375 Menu Tree 1 PV LRV PV URVC/T-HT HART/Model 375 Menu Tree 2 LSL USLAO1 LRV URVC/T-HT HART/Model 375 Menu Tree 4 PV AO PV LRV PV URVMaxnotify Resource FaultstateBlockerr Featuresel Rsstate Faultstate LimnotifyTagdesc AlarmhysStrev BlockerrStrev Statusopts Strategy Alertkey HihilimPvftime LowcutIoopts LolimLolopri LololimBkcalhys Ffgain ResetRate Reset Sphilim SplolimBypass BaltimeAlertkey Outhilim ControloptsSphilim Strev Rate TagdescDvlopri DvhipriC/T-FF/FI Model 375 Menu Tree 9 C/T-FF/FI Model 375 Menu Tree 10 Section Diagnosis and Troubleshooting OverviewCurrent Operating Menu Idvnut DLSTqiu 4DSGFault Conditions Disabling FaultsNON- Disabling Warnings 9WHS!S-PJ1 Hssqs9IITHU!1SS Field Troubleshooting Quick Troubleshooting GuideQuick Troubleshooting Guide Symptom ActionTroubleshooting Flow Chart Systematic TroubleshootingRTD Resistance Values RTD Resistance ValuesFormula ExampleWhen a Fault exists When a Warning condition existsCPU Fail Troubleshooting When a Fault or Warning Message is ShowingTemp HI Temp LORtd FAIL, Temp HI, and Temp LO CPU Fail and ROM Fail 0 C 2 1 0 % mA Section MaintenancePreventative Maintenance Transmitter MaintenanceExploded View of Model 5081-T Transmitter Replacement Parts for Model 5081-T TransmitterOutput Logic Section Theory of OperationConductivity Hart CommunicationGeneral Warranty RepairNON-WARRANTY Repair Section Return of MaterialThis page intentionally left blank Return of Material WarrantySpecifications subject to change without notice