Emerson ITR manual Table i Product model information, Split system configurations

Page 2

PRODUCT NOMENCLATURE

NOTE

Tables i, ii and iii show nomenclature for the complete range of all available product options. Not all combinations are possible. For assistance, contact your local dealer, Liebert representative or call 1-800-543-2778.

Table i Product model information

B

F

042

A

A

A

E

I

Challenger

R = ITR,

Nominal A-=Air-Cooled

 

A = 460/60/3

A = Advanced

0 = No Reheat

0 = No

ITR

Horizontal Flow

capacity in

 

 

 

Microprocessor

 

Humidifier

 

 

thousand

 

 

 

 

 

 

 

 

BTUH

 

 

 

 

 

 

 

M = ITR,

 

C-= Chilled

 

B = 575/60/3

G = Advanced

E = Electric

I = Infrared

 

Horizontal Flow

 

Water

 

 

Microprocessor

Reheat

Humidifier

 

with Econ-O-Coil

 

 

 

 

w/Graphics

 

 

 

 

 

E- = Evaporator

 

C = 208/60/3

 

H = Hot Water

S = Steam

 

 

 

 

 

 

 

Reheat

Generating

 

 

 

 

 

 

 

 

Humidifier

 

 

 

G-= GLYCOOL

 

D = 230/60/3

 

G = Hot Gas

 

 

 

 

 

 

 

 

Reheat

 

 

 

 

WG = Water-

 

2 = 380/60/3

 

S = SCR

 

 

 

 

Cooled/Glycol-

 

 

 

Reheat

 

 

 

 

cooled

 

 

 

 

 

 

 

 

 

 

J = 200/50/3

 

 

 

 

 

 

 

 

H = 230/50/3

 

 

 

 

 

 

 

 

M = 380/415/50/3

 

 

 

Table ii

Split system configurations

 

 

 

 

 

 

Condensing Units

 

 

 

 

 

Air-Cooled

 

Evaporator

Air-Cooled Prop Fan

Centrifugal

Water/Glycol

Condensing Unit

Condensing Unit

Condensing Unit

60 Hz

 

BR060E

PFH067A_ _H3

MC_65A

MC_69W

(50 Hz)

 

(BR059E)

PFH066A_ _H3

(MC_64A)

(MC_68W)

Table iii Self-contained system configurations

 

 

Remote Equipment

 

 

 

Air-Cooled

 

 

Frequency

Indoor Unit

Condenser

Drycooler/Pump

System Type

60 Hz (50 Hz)

BR067A (BR065A)

CS@104

 

Air-Cooled

 

 

 

DSF112

Glycol-Cooled or Self-

60 Hz (50 Hz)

BR071WG (BR070WG)

 

3/4 HP Pump 60 Hz

 

Contained - Water-Cooled

 

 

 

1-1/2 HP Pump 50 Hz

 

 

 

 

60 Hz (50 Hz)

BM061G (BM058G)

 

DSO112

GLYCOOL

 

 

 

1-1/2 HP Pump

 

60 Hz (50 Hz)

BR102C (BR101C)

 

 

Self-Contained - Chilled

 

 

Water

 

 

 

 

@

 

 

 

 

F = Fan Speed Control

 

 

 

L = Lee Temp

 

 

 

 

Image 2
Contents Liebert Challenger ITR Table i Product model information Split system configurationsTable iii Self-contained system configurations Table of Contents Refrigeration Systems AIR-COOLEDSYSTEM-STANDARD and Optional FeaturesGlycool SYSTEMS-STANDARD and Optional Features Optional EQUIPMENT-ALLSYSTEMSComprehensive Monitoring SYSTEMS-OPTIONAL Comprehensive Monitoring SOLUTIONS-OPTIONALSystem Data Dimensional Drawings Electrical Data Figures Page Page Humidity Control Temperature ControlAir Volume Air FiltrationEfficiency in Economic Terms Multiple Configurations to Fit a Variety of SpacesLiebert Challenger ITR Unit configurations Image is Illustrative only Control Type DiagnosticsControl Internal System ControlLogging AlarmsCustom Alarm Maximum of Four Graphical Displays-Advanced Graphic Control OnlyFan Section Cabinet and FrameElectrical Panel Infrared HumidifierCondensate Pump Remote Temperature/ Humidity SensorsDisconnect Switch-Locking Type Condensate pump capacityChilled Water System-Standard Features Chilled Water System-Optional FeaturesSplit Systems Refrigeration System Components-Standard FeaturesSelf-Contained Systems Air-Cooled, Self-Contained Systems-Standard Features Air-Cooled, Self-Contained Systems-Optional FeaturesCentrifugal Fan, Condensing Unit Air-Cooled Split Systems-Standard FeaturesAir-Cooled Split Systems-Optional Features Propeller Fan Condensing UnitWater/Glycol Self-Contained Systems-Standard Features Water/Glycol Split System-Standard FeaturesGlycol Pump Water/Glycol-Cooled, Split System-Optional FeaturesFactory Installed Non-Fused Disconnect Switch Glycool System-Standard Features GLYCOOL-Self-Contained Models OnlyQuiet-Line Drycoolers Glycol and GLYCOOL-Cooled-Optional EquipmentDrycooler Evaporator Coil Econ-O-Coil Three-way Glycool Control ValveSteam generating humidifier Adjustable Floor Stand Steam Generating HumidifierHigh External Static Blowers SCR ReheatHigh-Efficiency Filter High-Efficiency MotorsHot Water Reheat Smoke DetectorFirestat FirestatNetwork Monitoring Systems Stand-Alone Monitoring and Leak Detection SolutionsEnterprise Monitoring Systems Leak Detection Modules Discrete Output Interface CardLiebert Nform Liebert SiteScan WebLiebert SiteLink Environmental Discrete Outputs CardLeak Detection Temperature and Humidity RecorderUniversal Monitor Liebert Challenger ITR air-cooled data-60 Hz BR 067A BR 060EInfrared Humidifier Standard Fan Data Blower A12x9AT Liebert Challenger ITR air-cooled data-50 HzSystem Type Split Systems Evaporator Coil V-Frame, at Standard ConditionsCondenser Air 35C 95F Ambient Liebert Challenger ITR air-cooled data-50HzConnection Sizes Challenger ITR Unit Indoor Unit BR 071WG BR 060E Net Capacity Data Liebert Challenger ITR water cooled data, 60 HzSystem Type Self-Contained Split Systems Connection Sizes Remote Condensing Unit Water Regulating ValveWater Requirements Coaxial Condenser Liebert Challenger ITR water cooled data, 50 Hz BTU/HCapacity, kg/hr lb/hr Liebert Challenger ITR glycol cooled data, 60 Hz GlycoolIndoor Unit Steam Generating Humidifier OptionalLiebert Challenger ITR glycol cooled data, 50 Hz GlycoolDrycooler 35C 95F Ambient Glycol Pump 3-Phase kW hpSystem Type Glycol Cooled Liebert Challenger ITR chilled water data, 60 Hz Indoor Unit BR 102C Fan Data Blower A12x9ATLiebert Challenger ITR chilled water data, 50 Hz Indoor Unit BR 101CDimensional Drawings 50 Hz 60 Hz Unit Weight Models Lb. kgOptional Floor Stand Model Net Weight 60 Hz 50 Hz Lbs kg MC69W MC68W SL-11081 36-1/4Liebert Lee-Temp Receiver = 40 1016mm = 7-1/2 190mm Electrical Data Liebert Challenger ITR electrical data1-60 HzMotor Hp 2.2 kW Self-contained with SCR reheatMotor Hp 1.5 kW Electric Reheat Only Motor Hp 1.1 kWVoltage 208 230 460 575 60 Hz Scroll Compressor Scroll compressor and main fan for comparison purposes onlyOutdoor condensing units Main Fan Motor Hp 1.1 kWIndoor condensing units, water-cooled Outdoor condensing units-Quiet-LineIndoor condensing units, air-cooled Drycooler and pump package 95F 35C ambient Fan speed control condensersLiebert Lee-Temp condensers Voltage 208/230 460 575 GlycolLiebert Challenger ITR electrical data-50 Hz Scroll compressor and main fan for comparison only Indoor condensing units air-cooled Indoor condensing units water-cooledPumps Drycooler only 35C 95F ambient, three-phaseDrycooler only 35C 95F ambient, single phase Submittals SummaryDesign Requirements All SystemsAdvanced Microprocessor Control Standard Common Alarm AlarmsAudible Alarm DiagnosticsAdvanced Microprocessor Control with Graphics Optional CommunicationsAlarms Electric Reheat Standard Infrared Humidifier StandardSteam Generating Humidifier Optional Hot Water Reheat OptionalDirect Expansion Self-Contained Systems Centrifugal Fan Condenser Optional Fan Speed Control FSC Head Pressure Control StandardLiebert Lee-Temp Head Pressure Control Optional Two-way Water Regulating Valve with Bypass StandardOutdoor Unit Glycool Self-Contained SystemsOptional Disconnect Direct Expansion Split SystemsCentrifugal Fan Condensing Unit Ton ModelsOptional High Ambient Models Water or Glycol-Cooled Split SystemsOptional Quiet-Line Models Water or Glycol-Cooled Condensing UnitThree-way Chilled Water Valve Standard Flow Switch OptionalChilled Water Self-Contained Systems Chilled Water Coil Two-way Chilled Water Valve OptionalField Quality Control Comprehensive Monitoring SolutionsInstallation of Environmental Control Units Page Ti n Ne tIti That