12.0COMPREHENSIVE MONITORING SOLUTIONS—OPTIONAL

12.1Liebert SiteScan® Web

Liebert SiteScan Web is a monitoring solution for critical environments that utilize a facility-view approach. The system enables communications from Liebert environmental and power units—as well as many other pieces of analog or digital equipment to a front end software package that provides monitoring, control and alarm management.

Liebert SiteScan monitoring gives you decision making power to effectively manage the equipment that is critical to your business. Designed with flexibility for large, complex systems as well as smaller, single-site facilities, the Liebert SiteScan line of products can provide real-time status and alarms.

12.2Liebert SiteLink

The microprocessor-based module provides two-way communication between an existing building management system and up to 12 Liebert units via Modbus or BACnet.

12.3Liebert Nform

Liebert Nform centralizes the management of your distributed Liebert network equipment. Liebert Nform software solution combines full-scale monitoring with the use of the existing network infra- structure—so the cost of dedicated, out-of-band communications cabling is eliminated. It is both scal- able and adaptable so it can grow as your systems expand and needs change. Liebert Nform will monitor any Liebert SNMP device that supports a network interface, such as the Liebert IntelliSlot 485 Card With Adapter and the Liebert IntelliSlot Web/485 Card With Adapter. Authenticated alarm management and event notification ensures that alarms are detected and acted upon, which allows problems to be quickly resolved.

12.4Liebert IntelliSlot Web/485 Card With Adapter and Liebert IntelliSlot 485 Card With Adapter

The Liebert IntelliSlot Web/485 Card With Adapter and the Liebert IntelliSlot 485 Card With Adapter provide Ethernet connectivity for Liebert equipment. Operating status and alarms are com- municated via the network to external systems utilizing industry standard open protocols.

12.5Environmental Discrete Outputs Card

The Environmental Discrete Outputs Card (ENV-DO) provides 16 discrete outputs, corresponding to status and major alarm conditions. These Form-C contact closures provide a straightforward means to connect Liebert environmental units to Building Management Systems (BMS), I/O or alarm panels.

12.6Remote Contact Monitor (RCM4)

LEDs display customized alarm indication for any dry contact input including alarms for Liebert environmental, power and UPS systems. The RCM4 monitors and displays four dry contact points.

12.7Auto-Changeover Control

Up to eight environmental units can be automatically and centrally controlled for emergency switching and to balance unit runtime. The AC3 controls two or three units. The RAC2-8 controls two through eight units and has the ability to provide alarm notification to pagers.

Auto-Changeover -

RAC2-8

22

Image 30
Contents Liebert Challenger ITR Split system configurations Table iii Self-contained system configurationsTable i Product model information Table of Contents Refrigeration Systems AIR-COOLEDSYSTEM-STANDARD and Optional FeaturesGlycool SYSTEMS-STANDARD and Optional Features Optional EQUIPMENT-ALLSYSTEMSComprehensive Monitoring SOLUTIONS-OPTIONAL System Data Dimensional Drawings Electrical DataComprehensive Monitoring SYSTEMS-OPTIONAL Figures Page Page Humidity Control Temperature ControlAir Volume Air FiltrationMultiple Configurations to Fit a Variety of Spaces Liebert Challenger ITREfficiency in Economic Terms Unit configurations Image is Illustrative only Control Type DiagnosticsControl Internal System ControlLogging AlarmsCustom Alarm Maximum of Four Graphical Displays-Advanced Graphic Control OnlyFan Section Cabinet and FrameElectrical Panel Infrared HumidifierCondensate Pump Remote Temperature/ Humidity SensorsDisconnect Switch-Locking Type Condensate pump capacityChilled Water System-Standard Features Chilled Water System-Optional FeaturesRefrigeration System Components-Standard Features Self-Contained SystemsSplit Systems Air-Cooled, Self-Contained Systems-Standard Features Air-Cooled, Self-Contained Systems-Optional FeaturesCentrifugal Fan, Condensing Unit Air-Cooled Split Systems-Standard FeaturesAir-Cooled Split Systems-Optional Features Propeller Fan Condensing UnitWater/Glycol Self-Contained Systems-Standard Features Water/Glycol Split System-Standard FeaturesWater/Glycol-Cooled, Split System-Optional Features Factory Installed Non-Fused Disconnect SwitchGlycol Pump Glycool System-Standard Features GLYCOOL-Self-Contained Models OnlyQuiet-Line Drycoolers Glycol and GLYCOOL-Cooled-Optional EquipmentDrycooler Evaporator Coil Econ-O-Coil Three-way Glycool Control ValveSteam generating humidifier Adjustable Floor Stand Steam Generating HumidifierHigh External Static Blowers SCR ReheatHigh-Efficiency Filter High-Efficiency MotorsHot Water Reheat Smoke DetectorFirestat FirestatStand-Alone Monitoring and Leak Detection Solutions Enterprise Monitoring SystemsNetwork Monitoring Systems Leak Detection Modules Discrete Output Interface CardLiebert Nform Liebert SiteScan WebLiebert SiteLink Environmental Discrete Outputs CardTemperature and Humidity Recorder Universal MonitorLeak Detection Liebert Challenger ITR air-cooled data-60 Hz BR 067A BR 060EInfrared Humidifier Standard Fan Data Blower A12x9AT Liebert Challenger ITR air-cooled data-50 HzSystem Type Split Systems Evaporator Coil V-Frame, at Standard ConditionsLiebert Challenger ITR air-cooled data-50Hz Connection Sizes Challenger ITR UnitCondenser Air 35C 95F Ambient Liebert Challenger ITR water cooled data, 60 Hz System Type Self-Contained Split SystemsIndoor Unit BR 071WG BR 060E Net Capacity Data Water Regulating Valve Water Requirements Coaxial CondenserConnection Sizes Remote Condensing Unit Liebert Challenger ITR water cooled data, 50 Hz BTU/HCapacity, kg/hr lb/hr Liebert Challenger ITR glycol cooled data, 60 Hz GlycoolIndoor Unit Steam Generating Humidifier OptionalLiebert Challenger ITR glycol cooled data, 50 Hz GlycoolGlycol Pump 3-Phase kW hp System Type Glycol CooledDrycooler 35C 95F Ambient Liebert Challenger ITR chilled water data, 60 Hz Indoor Unit BR 102C Fan Data Blower A12x9ATLiebert Challenger ITR chilled water data, 50 Hz Indoor Unit BR 101CDimensional Drawings 50 Hz 60 Hz Unit Weight Models Lb. kgOptional Floor Stand Model Net Weight 60 Hz 50 Hz Lbs kg MC69W MC68W SL-11081 36-1/4Liebert Lee-Temp Receiver = 40 1016mm = 7-1/2 190mm Electrical Data Liebert Challenger ITR electrical data1-60 HzMotor Hp 2.2 kW Self-contained with SCR reheatMotor Hp 1.5 kW Electric Reheat Only Motor Hp 1.1 kWVoltage 208 230 460 575 60 Hz Scroll Compressor Scroll compressor and main fan for comparison purposes onlyOutdoor condensing units Main Fan Motor Hp 1.1 kWOutdoor condensing units-Quiet-Line Indoor condensing units, air-cooledIndoor condensing units, water-cooled Drycooler and pump package 95F 35C ambient Fan speed control condensersLiebert Lee-Temp condensers Voltage 208/230 460 575 GlycolLiebert Challenger ITR electrical data-50 Hz Scroll compressor and main fan for comparison only Indoor condensing units air-cooled Indoor condensing units water-cooledDrycooler only 35C 95F ambient, three-phase Drycooler only 35C 95F ambient, single phasePumps Submittals SummaryDesign Requirements All SystemsAdvanced Microprocessor Control Standard Common Alarm AlarmsAudible Alarm DiagnosticsAdvanced Microprocessor Control with Graphics Optional CommunicationsAlarms Electric Reheat Standard Infrared Humidifier StandardSteam Generating Humidifier Optional Hot Water Reheat OptionalDirect Expansion Self-Contained Systems Centrifugal Fan Condenser Optional Fan Speed Control FSC Head Pressure Control StandardLiebert Lee-Temp Head Pressure Control Optional Two-way Water Regulating Valve with Bypass StandardOutdoor Unit Glycool Self-Contained SystemsOptional Disconnect Direct Expansion Split SystemsCentrifugal Fan Condensing Unit Ton ModelsOptional High Ambient Models Water or Glycol-Cooled Split SystemsOptional Quiet-Line Models Water or Glycol-Cooled Condensing UnitThree-way Chilled Water Valve Standard Flow Switch OptionalChilled Water Self-Contained Systems Chilled Water Coil Two-way Chilled Water Valve OptionalComprehensive Monitoring Solutions Installation of Environmental Control UnitsField Quality Control Page Ti n Ne tIti That