TECHNICAL DATA
The XES Synergix 8850 Printer will operate within the specifications indicated in the table below for the respective markets. Current limit will be set as part of the installation procedure. The printer is not sensitive to the AC power service frequency and can operate at either 50hz or 60hz.
Table 6. Operating power
Market area | AC power service | Maximum current | First Print Out Time | |
|
| rating | consumption |
|
|
|
|
|
|
US/Canada | 115V | @ 20A | 17.6A | Less than 5 minutes* |
| 208V | – 240V @ 20A | 17.6A | Less than 3 minutes |
| 208V | – 240V @ 15A | 13.2A | Less than 4 minutes |
|
|
|
|
|
European Operations - | 230V | – 240V @ 16A | 16.0A | Less than 3 minutes |
Common Market |
|
|
|
|
United Kingdom | 230V | – 240V @ 13A | 13.0A | Less than 3.5 minutes |
|
|
|
|
|
Switzerland | 220V | @ 10A | 10.0A | Less than 5 minutes* |
|
|
|
|
|
Central/South America | 220V | – 240V @ 20A | 15A | Less than 3 minutes |
|
|
|
|
|
*Continuous operation at the rate of 10 "D" prints per minute cannot be assured at this power service.
The table below shows maximum print engine throughput in prints per minute. It assumes continuous printing from a single roll with no AC power limitation.
Table 7. Maximum prints per minute
US |
|
| Europe/Central and South America | ||
|
|
|
|
| |
Portrait |
| Landscape | Portrait | Landscape | |
|
|
|
|
| |
N/A |
| A = 23 | N/A | A4 = 24 | |
|
|
|
|
|
|
B = 13 |
| B = 18 | A3 | = 13 | A3 = 18 |
|
|
|
|
|
|
C = 10 |
| C = 13 | A2 | = 10 | A2 = 13 |
|
|
|
|
|
|
D = 7 |
| D = 10 | A1 | = 7 | A1 = 10 |
|
|
|
|
|
|
E = 5 |
| N/A | A0 | = 5 | N/A |
|
|
|
|
|
|
48 | XES SYNERGIX 8850 PRINTER OPERATOR MANUAL |