General Information

Safety and Regulatory Certifications

The 5975 Series MSD conforms to the following safety standards:

Canadian Standards Association (CSA): CAN/CSA–C22.2 No. 61010–1–04

CSA/Nationally Recognized Test Laboratory (NRTL): UL 61010–1

International Electrotechnical Commission (IEC): 61010–1

EuroNorm (EN): 61010–1

The 5975 Series MSD conforms to the following regulations on Electromagnetic Compatibility (EMC) and Radio Frequency Interference (RFI):

CISPR 11/EN 55011: Group 1, Class A

IEC/EN 61326

AUS/NZ

This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme a la norme NMB—001 du Canada.

The 5975 Series MSD is designed and manufactured under a quality system registered to ISO 9001.

Information

The Agilent Technologies 5975 Series MSD meets the following IEC (International Electro-technical Commission) classifications: Equipment Class I, Laboratory Equipment, Installation Category II, Pollution Degree 2.

This unit has been designed and tested in accordance with recognized safety standards and is designed for use indoors. If the instrument is used in a manner not specified by the manufacturer, the protection provided by the instrument may be impaired. Whenever the safety protection of the MSD has been compromised, disconnect the unit from all power sources and secure the unit against unintended operation.

Refer servicing to qualified service personnel. Substituting parts or performing any unauthorized modification to the instrument may result in a safety hazard.

Site Preparation Guide

11

Image 11
Contents Series Mass Selective Detectors U TI O N WA R N I N G Contents Power Cords General Information MSD versions Model number Product number Pump type Ionization modeInstrument Identification Many internal parts of the MSD carry dangerous voltages Important Safety WarningsMany parts are dangerously hot Electrostatic discharge is a threat to MSD electronicsWhen hydrogen gas is supplied to the instrument Hydrogen SafetyChemical Safety Information Safety and Regulatory CertificationsSymbols Sound emission declaration Electromagnetic compatibilityRecycling the Product CleaningSite Preparation Customer responsibility OverviewAgilent responsibility Compliance must exist prior to installationAnalysis Consulting services Other documentation Series MSD Troubleshooting and Maintenance ManualALS tray Space and Weight RequirementsSeries MSD Series GC Computer with monitor Product dimensions Site LAN network Communications RequirementsTelephone Voltage ranges of major components Electrical RequirementsConfiguration Measurement Nominal voltage Power configurationsRequired Power requirementsSupply Outlets Power consumption Product Line voltageSupply Outlets Power consumption Circuit rating Required Power plugs and cordOther electrical considerations Air Conditioning and Environmental Requirements Temperature, humidity, and altitudeTemperature Humidity relative Exhaust venting Airborne dustFume exhaust hood Purity Typical pressure range Typical flow, mL/min KPa psi Carrier and Reagent Gas RequirementsRegulators, tubing, and fittings Data system supplies Cleaning solventsLaboratory Supply Requirements Miscellaneous consumables Spare parts and consumablesPart number Ferrules Chemical ConsumablesCommonly used tools 5062-3506 Inspecting for damage Receiving the SystemDelivery and unloading Unpacking StorageVerification Installation and VerificationInstallation Sensitivity specifications Power Cords Power Cords Page Agilent Technologies