Site Preparation

Spare parts and consumables

The supplies and parts listed in Table 7 are used in the operation and maintenance of a 5975 Series MSD system. Keeping these parts on hand can reduce system downtime related to instrument maintenance and repair.

Table 7

Maintenance supplies and consumables

 

 

 

 

Description

 

Part number

 

 

Miscellaneous consumables

 

 

 

One-year maintenance kit

5183-0296

 

 

He/H2 gas filter for GC

5182-3468

 

 

Abrasive sheets (5/pk)

5061-5896

 

 

Cloths, lint-free (15/pk)

05980-60051

 

 

Cotton swabs (100/pk)

5080-5400

 

 

2,4,6-tris(perfluoroheptyl)-1,3,5-triazine (PFHT)

 

 

 

Foreline pump oil, Inland 45, 1 liter

6040-0834

 

 

EI filament (2/pk)

05972-60053

 

 

EI high temp filament

G2590-60053

 

 

Octafluoronapthalene (OFN)

8500-5441

 

 

Gloves, clean

 

 

 

 

large

 

8650-0030

 

 

 

small

 

8650-0029

 

 

Nitrile rubber gloves, medium

9300-1751

 

 

 

Filaments

 

 

 

 

CI (2/pk)

G1099-80053

 

 

EI high temp filament

G2590-60053

 

 

 

 

 

 

 

 

 

34

Site Preparation Guide

Image 34
Contents Series Mass Selective Detectors U TI O N WA R N I N G Contents Power Cords General Information Instrument Identification Model number Product number Pump type Ionization modeMSD versions Important Safety Warnings Many internal parts of the MSD carry dangerous voltagesElectrostatic discharge is a threat to MSD electronics Many parts are dangerously hotHydrogen Safety When hydrogen gas is supplied to the instrumentChemical Safety Safety and Regulatory Certifications InformationSymbols Electromagnetic compatibility Sound emission declarationCleaning Recycling the ProductSite Preparation Overview Customer responsibilityCompliance must exist prior to installation Agilent responsibilityAnalysis Consulting services Series MSD Troubleshooting and Maintenance Manual Other documentationSeries MSD Series GC Computer with monitor Space and Weight RequirementsALS tray Product dimensions Telephone Communications RequirementsSite LAN network Electrical Requirements Voltage ranges of major componentsPower configurations Configuration Measurement Nominal voltageProduct Line voltage Power requirementsSupply Outlets Power consumption RequiredPower plugs and cord Supply Outlets Power consumption Circuit rating RequiredOther electrical considerations Temperature Humidity relative Temperature, humidity, and altitudeAir Conditioning and Environmental Requirements Airborne dust Exhaust ventingFume exhaust hood Carrier and Reagent Gas Requirements Purity Typical pressure range Typical flow, mL/min KPa psiRegulators, tubing, and fittings Laboratory Supply Requirements Cleaning solventsData system supplies Part number Spare parts and consumablesMiscellaneous consumables Commonly used tools Chemical ConsumablesFerrules 5062-3506 Delivery and unloading Receiving the SystemInspecting for damage Storage UnpackingInstallation Installation and VerificationVerification Sensitivity specifications Power Cords Power Cords Page Agilent Technologies