Agilent Technologies 5975 manual Installation and Verification

Page 39

Site Preparation

Installation and Verification

Installation

Once the installation has begun, it should progress in a timely manner to completion. Delays due to inadequate site preparation could cause loss of instrument use during the warranty period. In extreme cases, Agilent Technologies may ask to be reimbursed for the additional time required to complete the installation.

The primary user and, if possible, all other users of the MSD should be present during installation to receive familiarization instruction from the Agilent Technologies service representative.

Verification

The final step in the installation process is system verification. Your Agilent Technologies service representative will test the system against Agilent Technologies specifications as documented for the product(s) or system(s) you have purchased. (Not all tests are performed for every system.)

The Agilent Technologies service representative will not test your

system against your standards or samples. Further, the Agilent Technologies service representative will not set up your laboratory procedures. Assistance with laboratory procedures can be obtained from your local Agilent Technologies Applications Engineer (AE) on a consulting basis at additional cost.

Site Preparation Guide

39

Image 39
Contents Series Mass Selective Detectors U TI O N WA R N I N G Contents Power Cords General Information Model number Product number Pump type Ionization mode Instrument IdentificationMSD versions Many internal parts of the MSD carry dangerous voltages Important Safety WarningsMany parts are dangerously hot Electrostatic discharge is a threat to MSD electronicsWhen hydrogen gas is supplied to the instrument Hydrogen SafetyChemical Safety Information Safety and Regulatory CertificationsSymbols Sound emission declaration Electromagnetic compatibilityRecycling the Product CleaningSite Preparation Customer responsibility OverviewAgilent responsibility Compliance must exist prior to installationAnalysis Consulting services Other documentation Series MSD Troubleshooting and Maintenance ManualSpace and Weight Requirements Series MSD Series GC Computer with monitorALS tray Product dimensions Communications Requirements TelephoneSite LAN network Voltage ranges of major components Electrical RequirementsConfiguration Measurement Nominal voltage Power configurationsRequired Power requirementsSupply Outlets Power consumption Product Line voltageSupply Outlets Power consumption Circuit rating Required Power plugs and cordOther electrical considerations Temperature, humidity, and altitude Temperature Humidity relativeAir Conditioning and Environmental Requirements Exhaust venting Airborne dustFume exhaust hood Purity Typical pressure range Typical flow, mL/min KPa psi Carrier and Reagent Gas RequirementsRegulators, tubing, and fittings Cleaning solvents Laboratory Supply RequirementsData system supplies Spare parts and consumables Part numberMiscellaneous consumables Chemical Consumables Commonly used toolsFerrules 5062-3506 Receiving the System Delivery and unloadingInspecting for damage Unpacking StorageInstallation and Verification InstallationVerification Sensitivity specifications Power Cords Power Cords Page Agilent Technologies