J601 (Operation Panel / LCD)
No. | Signal name | Function | Input / | |
Output | ||||
|
|
| ||
1 | GND | Ground | - | |
2 | PANEL_RSTX | Panel reset signal | OUT | |
3 | GND | Ground | - | |
4 | PANEL_INT | Panel interruption signal | IN | |
5 | +3.3V | LCD drive power supply +3.3V | OUT | |
6 | LVCLK- | LV clock- | OUT | |
7 | LVCLK+ | LV clock+ | OUT | |
8 | 5V | Power supply +5V | OUT | |
9 | LVDATA- | LV data- | OUT | |
10 | LVDATA+ | LV data+ | OUT | |
11 | GND | Ground | - | |
12 | RXD | Reception signal | IN | |
13 | TXD | Transmission signal | OUT | |
14 | ERROR_LED | Alarm LED | IN | |
15 | POWER_LED | Power LED | IN | |
16 | STOP_SW | Stop/Reset switch | IN | |
17 | POW_SW | Power switch | IN | |
18 | GND | Ground | - |
J701 (Carriage Motor)
No. | Signal name | Function |
1 | CR_M | CR motor+ |
2 | CR_MN | CR motor- |
J702 (LF Motor)
No. | Signal name | Function |
1 | LF_M | LF motor+ |
2 | LF_MN | LF motor- |
J703 (Purge Unit Motor)
No. | Signal name | Function |
1 | PG_MA | PG motor phase A+ |
2 | PG_MB | PG motor phase B+ |
3 | PG_MAN | PG motor phase A- |
4 | PG_MBN | PG motor phase B- |
Input / Output
OUT
OUT
Input / Output
OUT
OUT
Input / Output
OUT
OUT
OUT
OUT