28
ePowerSwitch | ePowerSwitch | Function |
ID Address | Outlet |
|
XX | X | X |
| ||
| 9 ? All | |
|
|
Every command must add “#” in the end.
Eg, 0111# turn on ePowerSwitch01, outlet A, 0120# turn off ePowerSwitch01, outlet B, 0142# to reset ePowerSwitch01, outlet D (turn off
immediately, and on after 10 seconds )
Remote user may punch in 8 digits to delay reset, on or off. Eg,
02813600# means turn ePowerSwitch02 outlet H on after 3600 minutes.
02803600# means turn ePowerSwitch02 outlet H off after 3600 minutes.
02823600# means reset ePowerSwitch02 outlet H after 3600 minutes.
Use combination of 0111XXXX# and 0112XXXX# to get different delay for reset, or create a longer command.
XXXXmax value is 9999, which is about 166 hours, or 6.94 days.
7.The ePowerSwitch will acknowledge received commands by issuing 2 short beeps otherwise a long beep indicate failure or not recognizable.
8.Change password. The default password is 123456789. User has to enter previous password in order to change password.
28