________________________________________________________________________
▪Press ENTER key button to complete the process.
▪The default setting is 192.168.0.246
4.4.4MAC Address
▪MAC Address of the unit is displayed. This is a fixed value and cannot be changed.
4.4.5UDP Port Number
▪This will display the UDP port number.
▪The default UDP port number is 03000. The UDP port number cannot be changed using the front panel keys.
Port number setting in this section is used for UDP with supplied PC program not TCP/IP with web browser or Telnet. For TCP/IP, port number 23 is fixed value.
.
4.4.6Video Generator
▪The Video Generator (Reference Output) is set at 1280x1024@60Hz with a Vertical Bar pattern. This output cannot be changed.
4.4.7Monitoring Output
▪It allocates input to Monitor Output port for monitoring uses.
▪The cursor shows that it is selected and activated.
▪Input 3 key button decreases the number.
▪Input 4 key button increases the number.
=Monitoring Output= Old Input: 01
New Input: 01
1)Connect a display to the Monitoring Output port and any video sources to the DVI input ports on the real panel.
2)Select an input port by pressing input 3 or 4 key button.
3)Press ENTER key button to complete the process.
4.4.8EDID Configure
▪Sets the EDID information in input port.
▪
▪The cursor shows that it is selected and activated.
▪Input 1 and 2 key buttons select YES and NO.
▪Input 3 and 4 key buttons move left and right (Change EDID mode).
▪Input 5 and 6 key buttons move down and up (Decrease and increase the port number).
20
User’s Guide | Rev. 01 |