Sets the IP, Gateway, Subnet mask, MAC address and UDP port number.

Requests current network setting.

Command

Description and reply

 

 

NETGW=192.168.1.1!

Sets Gateway address, each data ranges from 000 to 255.

Reply: NETGW=192.168.001.001!

 

NETIP=192.168.1.118!

Sets IP address, each data ranges from 000 to 255.

Reply: NETGW=192.168.001.118!

 

 

Sets Subnet mask address, each data ranges from 000 to

NETSN=255.255.255.0!

255.

 

Reply: NETSN=255.255.255.000!

NETPA=AA.BB.CC.DD.EE.FF!

Sets MAC address, each data ranges from 00 to FF.

 

Reply: NETPA= AA.BB.CC.DD.EE.FF!

NETPT=3000!

Sets UDP port number, data ranges from 0 to 65535.

NETPT=3000!

 

 

Requests current network setting.

 

Reply: NETGW=192.168.001.001!

NET=?!

NETIP=192.168.001.118!

NETSN=255.255.255.000!

 

 

NETPA=AA.BB.CC.DD.EE.FF!

 

NETPT=3000!

 

 

Table 7-4 : Network setting command examples

7.2.4Monitor output port setting

Makes an input connected to the Monitor Output port.

Requests input port that is currently connected to the Monitor Output port.

Command

Description and reply

 

 

MON=13!

Makes input 13 connected to monitor output ports.

Reply: MON=13!

 

 

 

 

Requests current input port that connected to monitor

MON=?!

output port.

 

Reply: MON=13!

Table 7-5: Monitor output setting command examples

7.2.5EDID control command

It stores EDID information in input port of MATRIXPRO-II DVI 16x16 .

It requests current EDID setting for all input ports.

33

User’s Guide

Rev. 01

Image 33
Contents Manual # Revision MatrixPRO-II DVI 16x16 Matrix Router User’s GuideUser’s Guide Rev Company Address Operators Safety Summary Terms in This Manual and Equipment Marking Cr6+ MatrixPRO-II DVI 16x16 Router Change History Table of Contents MatrixPRO-II DVI 16x16 Router Key Features IntroductionShipping Page Front panel of MATRIXPRO-II DVI 16 X Physical DescriptionEdid Configuration Installation InitializationEdid Control Setup TCP/IPLaunching Telnet RS-232 Launching HyperTerminal Front Panel Operation Link mode Unlink modeFunction mode Gateway Subnet MaskIP Address MAC Address Edid ConfigureUDP Port Number Video GeneratorPage Hdcp Configure Hdcp ConfigureReset Mode Baud RateControl Lock PC Program Operation Basic SetupConnect Info Edid setup Control Lock ModeChannel Name NetworkOperation Input / output connection Output channel status Web control panel operation Command input structure CommandsInput and output status Examples of command inputs Link input and outputNetwork setting Monitor output port settingEdid control command Baud rate setting for RS-232 Hdcp SettingLocking type and its Ascii data Control lock commandFirmware update Power-On the MATRIXPRO-II DVI Page Page Hdcp notes Video Inputs SpecificationsWarranty WarrantyTechnical Support USA Contact Information