7 Commands

The MATRIXPRO-II DVI 16x16 router can be operated with various interfaces such as key button inputs, command input through RS-232 and TCP/IP, Web control through TCP/IP and PC program through RS-232 and UDP. All functions are executed on a basis of a serial command input, but the graphic interfaces on the Web or the PC program are more efficient ways to operate the MATRIXPRO-II DVI 16x16 modular matrix.

Command input operation is accomplished through RS-232 or TCP/IP. For setting procedures using those protocols, please refer to Chap 2 and Chap 3.

7.1Command input structure

The command inputs are composed of a string of ASCII codes and its basic structure is;

Command + Delimiter (‘=’) + Data + Delimiter (‘^’ or ‘,’ or ‘_’) + Data + End (‘!’)

Table 6.1 shows all commands and its brief descriptions

Command

Description

LINK

Input and Output connection

 

 

IN

Input signal status request

 

 

OUT

Output signal status request

 

 

NET

Network information request

 

 

NETGW

Gateway address setting

 

 

NETSN

Subnet mask address setting

 

 

NETIP

IP address setting

 

 

NETPA

MAC address setting

 

 

NETPT

UDP port number setting

 

 

VID

Video generator status request

 

 

MON

Monitoring port setting and status request

 

 

EDID

EDID mode setting

 

 

HDCP

Enable/Disable HDCP

RS232

RS-232 Baud rate setting

LOCK

Lock/Unlock the control type

 

 

 

Table 7-1 : Commands set

The command input allows executing only one command. Multiple command inputs require executing multiple strings having each command per a string.

User can use capital letters and small letters for commands but cannot mix it like ‘Link’, it must be corrected as ‘link’ or ‘LINK’.

31

User’s Guide

Rev. 01

Image 31
Contents Manual # Revision MatrixPRO-II DVI 16x16 Matrix Router User’s GuideUser’s Guide Rev Company Address Operators Safety Summary Terms in This Manual and Equipment Marking Cr6+ MatrixPRO-II DVI 16x16 Router Change History Table of Contents MatrixPRO-II DVI 16x16 Router Introduction Key FeaturesShipping Page Front panel of MATRIXPRO-II DVI 16 X Physical DescriptionEdid Configuration Installation InitializationEdid TCP/IP Control SetupLaunching Telnet RS-232 Launching HyperTerminal Unlink mode Front Panel Operation Link modeFunction mode Subnet Mask GatewayIP Address Video Generator Edid ConfigureMAC Address UDP Port NumberPage Hdcp Configure Hdcp ConfigureBaud Rate Reset ModeControl Lock PC Program Operation Basic SetupConnect Info Network Control Lock ModeEdid setup Channel NameOperation Input / output connection Output channel status Web control panel operation Command input structure CommandsInput and output status Examples of command inputs Link input and outputMonitor output port setting Network settingEdid control command Baud rate setting for RS-232 Hdcp SettingLocking type and its Ascii data Control lock commandFirmware update Power-On the MATRIXPRO-II DVI Page Page Hdcp notes Video Inputs SpecificationsWarranty WarrantyTechnical Support USA Contact Information