________________________________________________________________________
▪After all input commands,
▪Input and output port number range from 1 to 16 and prefix, ‘0’ can be used such as ‘001’ and ‘010, but in the replies after the command inputs, the digits of port number are two such as ‘01’ and ‘10’.
7.2Examples of command inputs
7.2.1Link input and output
▪Makes single or
▪Makes disconnection of all inputs when used with ‘0’.
▪Requests inputs and outputs status of
Command |
| Description and reply |
|
|
|
LINK=01^10! |
| Makes input 1 connected to output 10. |
| Reply: LINK=01^10! | |
|
| |
|
|
|
LINK |
| Makes input 1 connected to output 3 and 4 to 7. |
=1^03,04^7! |
| Reply: LINK =01^03,04^07! |
LINK =05! |
| Makes input 5 connected to all outputs. |
| Reply: LINK=05! | |
|
| |
|
|
|
LINK =00! |
| Makes all connections disconnected. |
| Reply: LINK =00! | |
|
| |
|
|
|
LINK =00^06! |
| Makes output 6 disconnected. |
| Reply: LINK =00^06! | |
|
| |
|
|
|
|
| Requests current inputs and outputs connections |
Link=?! |
| status. |
|
| Reply: LINK =01^01,02^04,~16^13! |
| Table |
7.2.2Input and output status
▪Requests input signal status. If the input is connected, it replies input resolution, but if it is not connected, it returns ‘Signal Off’.
▪Requests output status whether it is connected to display or not.
Command | Description and reply | |
|
| |
IN=05! | Requests input 5 status. | |
Reply: IN=[05] 1920x1200p! or IN=[05] Signal Off! | ||
| ||
|
| |
OUT=12! | Requests output 12 status. | |
Reply: OUT=[12] Un Plugged! or OUT=[12] Plugged! | ||
| ||
|
|
Table
32