SATO LM408/412E Interface Selection, RS232C HIGH-SPEED Serial Interface, Interface Specifications

Page 22

Unit 3: Installation

INTERFACE SELECTION

This unit presents the printer interface types and their specifications. These specifications include detailed information to assist in the selection of the most appropriate method for the printer to interface with the host. The five acceptable interface methods are:

RS232C High-Speed Serial

IEEE1284 Parallel

Universal Serial Bus (USB)

Local Area network (LAN) Ethernet

802.11G Wireless

Following the selection of the desired interface, proceed to the next unit for instructions on how to Configure the printer for that interface type.

WARNING: NEVER CONNECT OR DISCONNECT INTERFACE CABLES (OR USE

A SWITCH BOX) WITH POWER APPLIED TO EITHER THE HOST OR THE

PRINTER. THIS MAY CAUSE DAMAGE TO THE INTERFACE CIRCUITRY IN THE

PRINTER/HOST AND IS NOT COVERED BY WARRANTY.

NOTE: Some hosts monitor the Request-To-Send (RTS) signal (pin 4 of 25) to determine if the printer is ready to receive data. Since the printer does not generate this signal, the RTS line must be held true (high) in order to allow communication. This can be performed by connecting the RTS pin to the Clear-To-Send (CTS) signal (pin 5 of 25).

NOTE: If assistance is required on the physical installation of the interface, refer to the

Accessories Installation unit for guidance.

RS232C HIGH-SPEED SERIAL INTERFACE

This High Speed Serial Interface is a Plug-In Interface Module that can be installed in the printer by the user.

 

INTERFACE SPECIFICATIONS

 

 

Asynchronous ASCII

Half-duplex communication

 

Bi-Directional Communication

 

 

Data Transmission Rate

9600, 19200, 38400, 57600 bps

 

 

Transmission Form

Start, b1, b2, b3, b4, b5, b6, b7, b8, Stop (b8 will be omitted if using 7 bit oriented)

 

 

Data Length

7 or 8 bit (selectable)

 

 

Stop Bit

1 or 2 bit (selectable)

 

 

Parity Bit

ODD, EVEN, NONE (selectable)

 

 

Codes Used

ASC II Character Codes: 7 bits, Graphics: 8 bits

 

 

Control Codes

STX (02H), ETX (03H), ACK (06H), NAK (15H)

 

 

Connector (Printer Side)

DB-25S Male (equivalent)

 

 

Cable Connector

DB-25P Female (equivalent)

 

 

Cable Length

5 meters or less.

 

 

Signal Levels

High = +5V to +12V, Low = -5V to -12V

 

 

Protocol

Ready/Busy, X-On/X-Off, Protocol for Driver, Status4

 

 

LM408-412e Operator Manual

3-7

PN: 9001155A

Image 22
Contents Printer Sato America, Inc Table of Contents Printer Configuration TroubleshootingAppendix MaintenanceOffset Introduction About this Manual Equipment DamageGeneral Descript 1a, Primary ComponentsOperator Panel Features LED Definition Control FeaturesDipswitches Definition Operator Panel Technical Data Environmental Physical CharacteristicsPower ProcessingMedia CommandSensing RibbonCharacter Font Capabilities MSI Barcode CapabiltiesUPC A/E PostnetInstallation Unpacking & Parts Identification Unpacking & Parts IdentificationSite Location Printer InstallationCable Connection Media Selection Media & Ribbon Loading3b, Fan-fold Media Loading TEAR-OFF Mode Operational Mode SelectionContinuous Mode Interface Selection Interface SpecificationsAccessories Installation unit for guidance RS232C HIGH-SPEED Serial InterfaceOFF ODD Even None PIN Direction Signal DefinitionOFF ON/X-OFF Printer READY/BUSY Cable Requirements DB9Host Direction ON/X-OFF Cable RequirementsIEEE1284 Parallel Interface SpecificationsPIN Assignments Signal Direction ACKUniversal Serial BUS USB Dipswitch SettingsSetting Local Area Network LAN Ethernet802.11G Wireless Interface Software SpecificationsSwitch Setting LED Indicator Status DescriptionALL Interfaces Interface SignalsCable Requirements Receive Buffer Control 50 of 500 items in the history bufferAccessories Installation Interface InstallationPrinter Configuration Unit 4 Printer Configuration Dipswitch Settings Dipswitch Functions Switch Setting DescriptionConfiguration Modes Normal ModeAdvanced Mode Advanced ModeUser Download Mode No changeService Mode ACK Signal XX.XCard Mode Card ModeMove Mode Motion ModeHistory Control Mode History Control ModeProtocol Initialization Mode DSW7 on Line + Feed + PowerCounters Mode Counters ModeTest Print Mode 10, Test Print ModeBoot Download Mode 11, Boot Download ModeFlash Memory Download Mode 12, Flash Memory Download ModeDefault Setting Mode YesHEX Dump Mode DSW4 on PowerMaintenance Mode 15, Maintenance ModeMenu Definition Tables Normal Mode TableMenu Description Advanced Mode Table Language options Transitional menu screen to access the Service ModeVoltageThreshold low voltage + high voltage = 12 volts Service Mode Table Is only a transitional menu screen to access the Move Mode Is only a transitional menu screen for the Service ModeOperator to the biginning of the Card Mode Transitional menu screen to access the Move ModeWithout pause for application Determined Continuous or Tear-OffHas been removed for application Counters Mode Table Transitional menu screen to access the Counters ModeBarcode The printer’s installed barcodes Is the initial screen of the Test Print ModeConfiguration The printer’s configuration settings Font The contents of the installed fontsTo proceed to the Factory Mode Maintenance Mode Table Troubleshooting Error Signal Troubleshooting Troubleshooting Table Incorrect Label Positioning No Printed ImagePrinter Creates a Blank Label Smeared Print ImagesInterface Troubleshooting CHK Troubleshooting StepLAN Ethernet Interface Test Print Troubleshooting DSW4 on PowerTest Label Printing FeedSample Test Label Maintenance Cleaning Procedures PRINTER, Excersize Care to Prevent Print Head DamageReplacement Procedures Print Head Replacement1a, Print Head Replacement Interface Board Replacement Interface Board ReplacementFuse Replacement Fuse ReplacementAdjustment Procedures Print Head Balance AdjustmentPrint Head Alignment 5a, Print Head AlignmentRibbon Guide Alignment Head Balance and Print Head AlignmentLabel Sensor Positioning Label Sensor PositioningRibbon Spindle Tensioning Ribbon Spindle TensioningPotentiometer DESCRIPTION/PROCEDURE Operational AdjustmentsDarkness Label Print Direction Appendix Print Setup Dimensions Print Setup DimensionsLabel Reference Position Reflective SensorLabel Adjustment Diagram 3a, Standard PositionPrinter Connection Diagram Printer Loading Diagram 5a, Printer Loading Diagram5c, Printer Loading Diagram Glossary GlossaryAscii Is a plug male and the other is a socket female Bytes Collection of 8 bits used in the binary systemBeing its mating half Half. The core is convexed and the cavity is concavedEeprom DPIDram Data transmission, seven additional bits are requiredNext label for printing PowerTag would typically have to be removed from its object To attach two or more objectsLCD LEDPotentiometer Or voltage divider PrimaryRF/DC RAMRF/AIS RfidSAM ROMRPM SbplSram Glossary