IBM Nortel 10 manual Removing the GbE switch module

Page 22
Removing the GbE switch module

12.Attach any cables that are required by the GbE switch module, see Chapter 4, “Cabling,” on page 21. For the locations of the connectors on the BladeCenter unit, see the documents that came with the BladeCenter unit.

13.Replace the acoustic-attenuation module, if you removed it in Step 2.

Removing the GbE switch module

To remove the GbE switch module, complete the following steps:

1.Read the safety information beginning on page v and “Installation guidelines” on page 9.

2.Remove the acoustic-attenuation module, if one is installed, from the rear of the BladeCenter unit. For more information, see the documents that came with the BladeCenter unit.

3.Disconnect any cables from the GbE switch module that you are removing.

4.Pull the release latch toward the bottom of the GbE switch module as shown in the following illustration. The module moves out of the bay approximately 0.64 cm (0.25 inch).

RS232

LINK

1 TX/RX LINK

2 TX/RX LINK

3 TX/RX LINK

4 TX/RX

I/O module

Release latch

5.Slide the GbE switch module out of the bay and set it aside.

6.Place either another GbE switch module or a filler module in the bay within 1 minute.

7.If you placed another GbE switch module in the bay, reconnect any cables that you disconnected. For more information about cabling the 10GbE switch module, see Chapter 4, “Cabling,” on page 21.

12Nortel 10 Gigabit Uplink Ethernet Switch Module: Installation Guide

Image 22
Contents Nortel 10 Gigabit Uplink Ethernet Switch Installation GuideModule for IBM BladeCenter Page Nortel 10 Gigabit Uplink Ethernet Switch First Edition May Chapter 2. Installing and removing the GbE switch module ContentsSafety Chapter 3. Installing and removing optionsAppendix A. IBM Statement of Limited Warranty Z125-4753-08 04/2004 Chapter 7. Parts listingChapter 8. Solving problems Chapter 6. Updating the softwareSafety vi Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide Antes de instalar este produto, leia as Informações sobre SegurançaStatement DANGER To avoid a shock hazardPage Media access control MAC address label Chapter 1. IntroductionProduct name and serial number label v Safety Information SpecificationsMedia access control MAC address Related documentationv IBM BladeCenter Management Module Command Line Reference Guide Notices and statements used in this document4 TX/RX XFP port Major components of the GbE switch moduleInformation panel RS232 serial console port CX4 ports Release latch SFP portCX 4 port Information panel overviewRS232 serial port XFP moduleLEDs TX/RXChapter 1. Introducing the Gigabit Ethernet switch module 8 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide Chapter 2. Installing and removing the GbE switch module Installation guidelinesSystem reliability considerations Installing the GbE switch moduleHandling static-sensitive devices 6. Remove the GbE switch module from its static-protective package Removing the GbE switch module 12 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation GuideChapter 2. Installing and removing the GbE switch module 14 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide Handling an XFP or SFP module Chapter 3. Installing and removing optionsStatement Class 1 Laser Product Laser Klasse Laser Klass Luokan 1 Laserlaite ` Installing an XFP moduleDANGER Appareil A Laser de ClasseLINK Chapter 3. Installing and removing optionsTX/RX Removing an XFP module Installing an SFP moduleWire tab Protective cap XFP module Removing an SFP module SFP module20 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide Connecting the CX4 module cable Connecting the serial console cableDisconnecting the serial console cable Chapter 4. CablingDisconnecting a CX4 module cable Connecting an XFP module cable1. Remove the protective caps from the end of the fiber-optic cable Connecting the SFP module cable Disconnecting the XFP module cableDisconnecting an SFP module cable Chapter 5. Configuring the GbE switch module 26 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide Establishing a TCP/IP session using the management module 2. From the I/O Module Tasks menu, click ConfigurationExternal management Configuring the GbE switch module using TelnetEnabling management over external ports External portsAccessing the main menu Connecting to the GbE switch moduleConfiguring the GbE switch module using the serial-port interface v 9600 baud v 8 data bits v No parity v 1 stop bit v No flow control Initial configuration Logging in to the GbE switch module Chapter 6. Updating the software Determining the level of GbE switch module softwareObtaining the latest level of switch software 3. Locate the I/O Module Firmware VPD sectionUpgrading the GbE switch module software Resetting and restarting the GbE switch module 3. Click Power Off Modules36 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide Chapter 7. Parts listing 38 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide POST errors Chapter 8. Solving problemsRunning POST Failing functional area Diagnostic indicator in40 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide Failure criticalityChapter 9. Getting help and technical assistance Using the documentationBefore you call Getting help and information from the World Wide Web Software service and supportHardware service and support 42 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation GuideWhat this Warranty Does not Cover Appendix A. IBM Statement of Limited Warranty Z125-4753-08 04/2004What this Warranty Covers Part 1 - General TermsHow to Obtain Warranty Service What IBM Will Do to Correct ProblemsExchange of a Machine or Part Your Additional ResponsibilitiesLimitation of Liability Governing LawAMERICAS ARGENTINA Part 2 - Country-unique TermsJurisdiction Jurisdiction The following is added after the first sentenceMEXICO COLOMBIAEQUADOR PARAGUAYLimitation of Liability The following replaces item 1 of this section NORTH AMERICACANADA UNITED STATESArbitration The following is added under this heading CAMBODIA AND LAOSCAMBODIA, INDONESIA, AND LAOS HONG KONG S.A.R. OF CHINA AND MACAU S.A.R. OF CHINAGoverning Law The following sentence is added to this section JAPANMALAYSIA PEOPLE’S REPUBLIC OF CHINA PRC NEW ZEALANDPHILIPPINES EUROPE, MIDDLE EAST, AFRICA EMEA SINGAPORETHE FOLLOWING TERMS APPLY TO ALL EMEA COUNTRIES Jurisdiction The following exceptions are added to this section 1 “the laws of Austria” in Albania, Armenia, Azerbaijan, Belarus54 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide Cameroon, Cape Verde, Central African Republic, Chad, Comoros, Congo Republic, Djibouti, Democratic Republic of Congo, Equatorial Guinea, French Guiana, French Polynesia, Gabon, Gambia, Guinea, Guinea-Bissau, Ivory Coast, Lebanon, Madagascar, Mali, Mauritania, Mauritius, Mayotte, Morocco, New Caledonia, Niger, Reunion, Senegal, Seychelles, Togo, Tunisia, Vanuatu, and Wallis & Futuna all disputes arising out of this Statement of Limited Warranty or related to its violation or execution, including summary proceedings, will be settled exclusively by the Commercial Court of Paris 5 in Russia, all disputes arising out of or in relation to the interpretation, the violation, the termination, the nullity of the execution of this Statement of Limited Warranty shall be settled by Arbitration Court of Moscow 6 in South Africa, Namibia, Lesotho and Swaziland, both of us agree to submit all disputes relating to this Statement of Limited Warranty to the jurisdiction of the High Court in Johannesburg 7 in Turkey all disputes arising out of or in connection with this Statement of Limited Warranty shall be resolved by the Istanbul Central Sultanahmet Courts and Execution Directorates of Istanbul, the Republic of Turkey 8 in each of the following specified countries, any legal claim arising out of this Statement of Limited Warranty will be brought before, and settled exclusively by, the competent court of a Athens for Greece THE FOLLOWING TERMS APPLY TO ALL EU COUNTRIES How to Obtain Warranty Service The following is added to this sectionEUROPEAN UNION EU CONSUMERSFRANCE AND BELGIUM THE FOLLOWING TERMS APPLY TO THE COUNTRY SPECIFIED AUSTRIAThe following sentence is added to the end of item The following paragraphs are added to this sectionThe second paragraph does not apply EGYPTGERMANY HUNGARYIRELAND What this Warranty Covers The following is added to this sectionItems for Which IBM is Not Liable SOUTH AFRICA, NAMIBIA, BOTSWANA, LESOTHO AND SWAZILAND SLOVAKIAUNITED KINGDOM Nortel 10 Gigabit Uplink Ethernet Switch Module for IBM BladeCenter Part 3 - Warranty InformationWarranty Period Types of Warranty Service3. Courier or Depot Service 1. Customer Replaceable Unit “CRU” Service2. On-site Service 4. Customer Carry-In or Mail-In Service7. CRU and Customer Carry-In or Mail-In Service EU Country Telephone ListAppendix A. IBM Statement of Limited Warranty Z125-4753-08 04/2004 Italy -- +39-800-820-09466 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide IBM Director of Licensing IBM Corporation North Castle Drive Appendix B. NoticesArmonk, NY U.S.A Trademarks Product recycling and disposal Important notesAppendix B. Notices 70 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide Electronic emission notices Battery return programFederal Communications Commission FCC statement Australia and New Zealand Class A statement United Kingdom telecommunications safety requirementIndustry Canada Class A emission compliance statement European Union EMC Directive conformance statementTaiwanese Class A warning statement Chinese Class A warning statement Japanese Voluntary Control Council for Interference VCCI statement74 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide Index A 76 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide Index 78 Nortel 10 Gigabit Uplink Ethernet Switch Module Installation Guide Page 1P P/N 31R1719