Fujitsu MAS3367FC, MAS3735FC manual Index, Mode SELECT/MODE, Mtbf Mttr, Pad

Page 106

Index

example of FC-AL system configuration

....... 1-7

external dimension

4-1

external magnetic field

4-6

F

 

 

factory maintenance

6-8

FC model drives outer view

1-5

FC-AL standard

1-2

FC-SCA connector

A-2

fibre channel interface error

7-4

field maintenance

6-8

finding possibly faulty part

6-16

format capacity

3-9

format of extended sense data

7-2

format parameter

5-10, 5-11

FORMAT UNIT command

5-11

formatting

5-10

function specification

2-2

G

 

 

gap

3-8

general description

1-1

general note

5-1

H

 

 

hardware function test

6-2

hardware specification

2-1

hardware structure

1-5

head

1-6

high speed positioning

1-4

high-speed data transfer

1-2

I

 

 

indicating revision number

6-10

indicating revision number at

 

 

factory shipment

6-9

initial seek operation check

6-12

initial self-diagnostic

6-2

installation

5-1

installation requirement

4-1

installation/removal/replacement

5-2

interface connector signal allocation

A-2

interface test

6-5

internal test space

3-4

L

 

 

large capacity

1-4

leak magnetic flux

4-6

limitation of bottom-mounting

4-5

limitation of side-mounting

4-4

logical data block addressing

3-9

loop

6-5

low noise and low vibration

1-5

low power consumption

1-5

maintenance level

6-8

maintenance requirement

6-6

microcode downloading

1-5

MODE SELECT/MODE

 

SELECT EXTENDED command

5-10

model name and order number

2-1

motor start mode

5-3

mounting

4-3

mounting drive

5-4

mounting frame structure

4-3

mounting procedure

5-4

mounting requirement

4-1

MTBF

2-5

MTTR

2-6

N

 

noise filter

4-8

note on handling drive

5-1

note on mounting

4-3

O

 

online self-diagnostic

6-3

operation check

6-12

operation test

6-12

other

4-6

outline of troubleshooting procedure

6-13

P

 

packaging

5-2

PAD

3-8

page code = 1

5-13

page code = 2

5-14

page code = 3

5-10

page code = 7

5-13

part replacement

6-8

part that can be replaced in field

6-7

physical sector allocation

3-5

PLO Sync

3-8

positioning error rate

2-5

power on/off sequence

4-7

power supply requirement

4-7

precaution

6-5

preventive maintenance

6-6

programmable data block length

1-4

programmable multi-segment data buffer

1-2

R

 

random/sequential read test

6-5

read/write circuit

1-7

read/write error recovery parameter

5-13

reliability

2-5

reporting result of self-diagnostic and error

 

indication

6-3

IN-2

C141-E198

Image 106
Contents MAS3735FC MAS3367FC Disk Drives PRODUCT/MAINTENANCE Manual For Safe Operation Revision History This page is intentionally left blank Preface Overview of ManualPreface Conventions for Alert MessagesC141-E198 Iii This page is intentionally left blank Important Alert Items Important Alert MessagesImportant Alert Items C141-E198 Vii This page is intentionally left blank Maintenance Manual Manual Organization ProductFibre Channel Arbitrated Loop FC-AL Fibre Channel Physical and Signaling Interface FC-PHFibre Channel Physical and Signaling INTERFACE-2 FC-PH-2 Fibre Channel Plotocol for Scsi SCSI-FCPContents Installation ContentsAppendix a Connector Signal Allocation Figures Tables This page is intentionally left blank Standard Features Hardware Structure System Configuration General DescriptionStandard Features General DescriptionStandard Features General Description Hardware Structure FC model drives outer viewDisk/head configuration MAS3735FC MAS3367FCSystem Configuration Example of FC-AL system configurationGeneral Description Model names and order numbers Hardware SpecificationsHardware Specifications Model name and order number MAS3735FC32/34 Meeprml SpecificationsFunction specifications FC-ALHardware Specifications Environmental/power requirements Environmental specificationsIops Error rate ReliabilityMTBF= Hardware Specifications This page is intentionally left blank Data Space Logical Data Block Addressing Defect Management Cylinder configurationData Space Data Format Data Space Zone layout and track capacityAlternate spare area Data Space Track formatMsec Servo frame = 211 zone 0 ~ 266 zone Track skew/head skew Sector formatData Format Logical Data Block Addressing Format capacityData Format Defect Management Defect list Defect ManagementAlternate block allocation Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Write Write Extend Defect Management This page is intentionally left blank Installation Requirements Mounting Requirements External dimensionsInstallation Requirements Mounting Requirements MountingMounting frame structure HDC Surface temperature check pointMPU Service clearance area Power Supply Requirements Current waveform +12 VDCAC noise filter recommended Connection Requirements Connector Connection Requirements10 SCA2 type connector Installation Installation Mode settings SettingSetting Loop ID setting Motor start modeMounting Drives Mounting procedures Dismounting Drives Installation Checking connection Checking the IDD connection a Checking the IDD connection B Formatting C141-E198 Setting parameters Awre ArreArre Awre PER Xffff DiscXxxx Read/write Diagnostics Self-diagnostics Self-diagnostic functionsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information Maintenance Information PrecautionsMaintenance requirements Maintenance Information Maintenance levels Revision numbers Revision label exampleIndicating revision numbers Tools and test equipment TestsTest flowchart Operation Check Initial seek operation check Diagnostic testOperation test Troubleshooting Procedures Troubleshooting with disk drive replacement in the fieldSystem-level field troubleshooting Troubleshooting at the repair site Disk drive troubleshootingTroubleshooting with parts replacement in the factory Finding possibly faulty partsError Analysis Information Collection Sense data Error Analysis Information Collection Sense Data AnalysisSense key, sense code, and subsense code LSB Error AnalysisILI SksvSense Data Analysis Definition of sense dataSense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-40-xx, 4-44-xx, and 4-C4-xxAppendix a Connector Signal Allocation Connector Signal Allocation Glossary Glossary Target TargAcronyms and Abbreviations Acronyms and Abbreviations RSVBcrc ECCMtbf Mttr Mode SELECT/MODEIndex PADC141-E198 IN-3 This page is intentionally left blank Fujitsu Canada INC This page is intentionally left blank READER’S Comment Form This page is intentionally left blank