Fujitsu MAS3735FC, MAS3367FC manual Error rate, Reliability

Page 33

2.1 Hardware Specifications

(*1) For detail condition, see Section 4.1.

(*2) Vibration applied to the drive is measured at near the mounting screw hole on the frame as much as possible.

(*3) At random seek write/read and default on retry setting with log sweep vibration.

(*4) At power-off state after installation

Vibration displacement should be less than 2.5 mm.

(*5) Input voltages are specified at the drive connector side, during drive ready state.

(*6) High frequency noise (over 20MHz) is less than 100 mVp-p.

2.1.4Error rate

Errors detected during initialization and replaced by alternate block assignments are not included in the error rate. Data blocks to be accessed should be distributed over the disk medium equally.

(1)Unrecoverable error rate

Errors which cannot be recovered within 63 retries and ECC correction should not exceed 1 per 1015 bits.

Data loss

For MAS series, Reed Solomon codes are applied for their ECC. The sector-data is divided into 4 interleaving sectors, and ECC is performed in each sector where the maximum number of errors (up to

5 byte) can be corrected. [Total maximum byte: 5 byte × 4 ( interleave) = 20 byte]

If the error of read sector keeps allowable error byte number, correction is performed. However, if error byte exceeds its allowable number, correction may not be performed properly.

(2)Positioning error rate

Positioning errors which can be recovered by one retry should be 10 or less per 108 seeks.

2.1.5Reliability

(1)Mean Time Between Failures (MTBF)

MTBF of the IDD during its life time is 1,2000,000 hours (operating: 24 hours/day, 7 days/week

average DE surface temperature: 50°C or less).

C141-E198

2-5

Image 33
Contents MAS3735FC MAS3367FC Disk Drives PRODUCT/MAINTENANCE Manual For Safe Operation Revision History This page is intentionally left blank Overview of Manual PrefaceConventions for Alert Messages PrefaceC141-E198 Iii This page is intentionally left blank Important Alert Messages Important Alert ItemsImportant Alert Items C141-E198 Vii This page is intentionally left blank Manual Organization Product Maintenance ManualFibre Channel Physical and Signaling INTERFACE-2 FC-PH-2 Fibre Channel Physical and Signaling Interface FC-PHFibre Channel Arbitrated Loop FC-AL Fibre Channel Plotocol for Scsi SCSI-FCPContents Contents InstallationAppendix a Connector Signal Allocation Figures Tables This page is intentionally left blank General Description Standard Features Hardware Structure System ConfigurationGeneral Description Standard FeaturesStandard Features General Description FC model drives outer view Hardware StructureMAS3735FC MAS3367FC Disk/head configurationExample of FC-AL system configuration System ConfigurationGeneral Description Hardware Specifications Model name and order number Hardware SpecificationsModel names and order numbers MAS3735FC Function specifications Specifications 32/34 Meeprml FC-ALHardware Specifications Environmental specifications Environmental/power requirementsIops Reliability Error rateMTBF= Hardware Specifications This page is intentionally left blank Cylinder configuration Data Space Logical Data Block Addressing Defect ManagementData Space Data Format Zone layout and track capacity Data SpaceAlternate spare area Track format Data SpaceMsec Servo frame = 211 zone 0 ~ 266 zone Sector format Track skew/head skewData Format Format capacity Logical Data Block AddressingData Format Defect Management Defect Management Defect listAlternate block allocation Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Write Write Extend Defect Management This page is intentionally left blank Mounting Requirements External dimensions Installation RequirementsInstallation Requirements Mounting Mounting RequirementsMounting frame structure Surface temperature check point HDCMPU Service clearance area Current waveform +12 VDC Power Supply RequirementsAC noise filter recommended Connection Requirements Connection Requirements Connector10 SCA2 type connector Installation Installation Setting Loop ID setting SettingMode settings Motor start modeMounting Drives Mounting procedures Dismounting Drives Installation Checking connection Checking the IDD connection a Checking the IDD connection B Formatting C141-E198 Setting parameters Arre AwreArre Awre PER Disc XffffXxxx Read/write Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information Precautions Maintenance InformationMaintenance requirements Maintenance Information Maintenance levels Revision label example Revision numbersTests Indicating revision numbers Tools and test equipmentTest flowchart Diagnostic test Operation Check Initial seek operation checkOperation test Troubleshooting with disk drive replacement in the field Troubleshooting ProceduresSystem-level field troubleshooting Disk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting with parts replacement in the factoryError Analysis Information Collection Sense Data Analysis Error Analysis Information Collection Sense dataSense key, sense code, and subsense code ILI Error AnalysisLSB SksvDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-40-xx, 4-44-xx, and 4-C4-xx Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorAppendix a Connector Signal Allocation Connector Signal Allocation Glossary Target Targ GlossaryAcronyms and Abbreviations RSV Acronyms and AbbreviationsECC BcrcIndex Mode SELECT/MODEMtbf Mttr PADC141-E198 IN-3 This page is intentionally left blank Fujitsu Canada INC This page is intentionally left blank READER’S Comment Form This page is intentionally left blank