Fujitsu MAS3735FC, MAS3367FC manual Test flowchart

Page 89

6.2 Maintenance Information

Start

Start self-test by turning the power on

Test results OK?

No

Check host system

 

 

 

 

 

 

 

 

(Table 6.2)

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

Host system

Execute an operation

 

 

 

 

 

 

 

 

 

 

 

test using a host

 

 

 

normal?

 

computer or test

 

 

 

Yes

 

equipment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replaced or repair

 

Test results OK?

No

 

 

disk drive

 

 

 

 

 

 

 

 

Disk drive

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

normal?

 

 

 

 

 

 

Yes

 

Continue operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Execute diagnostic

 

 

 

 

 

 

 

 

 

 

 

 

test using a host

 

 

 

 

 

 

computer or test

 

 

 

 

 

 

equipment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

Test results OK?

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

Test using voltage or

 

 

 

 

 

 

temperature stress

 

 

 

 

 

 

 

 

 

 

 

 

 

Test results OK?

No

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

 

 

 

 

 

 

 

 

Figure 6.3 Test flowchart

Analyze system-related error

Analyze disk drive error (Table 6.3)

C141-E198

6-11

Image 89
Contents MAS3735FC MAS3367FC Disk Drives PRODUCT/MAINTENANCE Manual For Safe Operation Revision History This page is intentionally left blank Overview of Manual PrefaceConventions for Alert Messages PrefaceC141-E198 Iii This page is intentionally left blank Important Alert Messages Important Alert ItemsImportant Alert Items C141-E198 Vii This page is intentionally left blank Manual Organization Product Maintenance ManualFibre Channel Physical and Signaling INTERFACE-2 FC-PH-2 Fibre Channel Physical and Signaling Interface FC-PHFibre Channel Arbitrated Loop FC-AL Fibre Channel Plotocol for Scsi SCSI-FCPContents Contents InstallationAppendix a Connector Signal Allocation Figures Tables This page is intentionally left blank General Description Standard Features Hardware Structure System ConfigurationGeneral Description Standard FeaturesStandard Features General Description FC model drives outer view Hardware StructureMAS3735FC MAS3367FC Disk/head configurationExample of FC-AL system configuration System ConfigurationGeneral Description Hardware Specifications Model name and order number Hardware SpecificationsModel names and order numbers MAS3735FCFunction specifications Specifications32/34 Meeprml FC-ALHardware Specifications Iops Environmental specificationsEnvironmental/power requirements Reliability Error rateMTBF= Hardware Specifications This page is intentionally left blank Data Space Cylinder configurationData Space Logical Data Block Addressing Defect Management Data Format Zone layout and track capacity Data SpaceAlternate spare area Track format Data SpaceMsec Servo frame = 211 zone 0 ~ 266 zone Sector format Track skew/head skewData Format Format capacity Logical Data Block AddressingData Format Alternate block allocation Defect ManagementDefect Management Defect list Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Write Write Extend Defect Management This page is intentionally left blank Mounting Requirements External dimensions Installation RequirementsInstallation Requirements Mounting Mounting RequirementsMounting frame structure MPU Surface temperature check pointHDC Service clearance area Current waveform +12 VDC Power Supply RequirementsAC noise filter recommended Connection Requirements Connection Requirements Connector10 SCA2 type connector Installation Installation Setting Loop ID setting SettingMode settings Motor start modeMounting Drives Mounting procedures Dismounting Drives Installation Checking connection Checking the IDD connection a Checking the IDD connection B Formatting C141-E198 Setting parameters Arre AwreArre Awre PER Xxxx DiscXffff Read/write Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information Precautions Maintenance InformationMaintenance requirements Maintenance Information Maintenance levels Revision label example Revision numbersTests Indicating revision numbers Tools and test equipmentTest flowchart Operation test Diagnostic testOperation Check Initial seek operation check Troubleshooting with disk drive replacement in the field Troubleshooting ProceduresSystem-level field troubleshooting Disk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting with parts replacement in the factorySense key, sense code, and subsense code Error Analysis Information Collection Sense Data AnalysisError Analysis Information Collection Sense data ILI Error AnalysisLSB SksvDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-40-xx, 4-44-xx, and 4-C4-xx Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorAppendix a Connector Signal Allocation Connector Signal Allocation Glossary Target Targ GlossaryAcronyms and Abbreviations RSV Acronyms and AbbreviationsECC BcrcIndex Mode SELECT/MODEMtbf Mttr PADC141-E198 IN-3 This page is intentionally left blank Fujitsu Canada INC This page is intentionally left blank READER’S Comment Form This page is intentionally left blank