Fujitsu MAS3367FC, MAS3735FC manual Mtbf=

Page 34

Specifications

Note:

The MTBF is defined as:

Operating time (hours) at all field sites

MTBF=

The number of equipment failures from all field sites

Failure of the equipment means failure that requires repair, adjustments, or replacement. Mishandling by the operator, failures due to bad environmental conditions, power trouble, host system trouble, cable failures, or other failures not caused by the equipment are not considered.

(2)Mean Time To Repair (MTTR)

MTTR is the average time taken by a well-trained service mechanic to diagnose and repair a drive malfunction. The drive is designed for a MTTR of 30 minutes or less.

(3)Service life

The service life under suitable conditions and treatment is as follows.

The service life is depending on the environment temperature. Therefore, the user must design the system cabinet so that the average DE surface temperature is as possible as low.

DE surface temperature: 40°C or less

5 years

DE surface temperature: 41°C to 45°C

4.5 years

DE surface temperature: 46°C to 50°C

4 years

DE surface temperature: 51°C to 55°C

3.5 years

DE surface temperature: 56°C to 60°C

3 years

DE surface temperature: 61°C and more

Strengthen cooling power so that DE surface

 

 

temperature is 60°C or less.

Even if the IDD is used intermittently, the longest service life is 5 years.

Note:

The "average DE surface temperature" means the average temperature at the DE surface throughout the year when the IDD is operating.

2-6

C141-E198

Image 34
Contents MAS3735FC MAS3367FC Disk Drives PRODUCT/MAINTENANCE Manual For Safe Operation Revision History This page is intentionally left blank Preface Overview of ManualPreface Conventions for Alert MessagesC141-E198 Iii This page is intentionally left blank Important Alert Items Important Alert MessagesImportant Alert Items C141-E198 Vii This page is intentionally left blank Maintenance Manual Manual Organization ProductFibre Channel Arbitrated Loop FC-AL Fibre Channel Physical and Signaling Interface FC-PHFibre Channel Physical and Signaling INTERFACE-2 FC-PH-2 Fibre Channel Plotocol for Scsi SCSI-FCPContents Installation ContentsAppendix a Connector Signal Allocation Figures Tables This page is intentionally left blank Standard Features Hardware Structure System Configuration General DescriptionStandard Features General DescriptionStandard Features General Description Hardware Structure FC model drives outer viewDisk/head configuration MAS3735FC MAS3367FCSystem Configuration Example of FC-AL system configurationGeneral Description Model names and order numbers Hardware SpecificationsHardware Specifications Model name and order number MAS3735FC32/34 Meeprml SpecificationsFunction specifications FC-AL Hardware Specifications Environmental/power requirements Environmental specificationsIops Error rate ReliabilityMTBF= Hardware Specifications This page is intentionally left blank Data Space Logical Data Block Addressing Defect Management Cylinder configurationData Space Data Format Data Space Zone layout and track capacityAlternate spare area Data Space Track formatMsec Servo frame = 211 zone 0 ~ 266 zone Track skew/head skew Sector formatData Format Logical Data Block Addressing Format capacityData Format Defect Management Defect list Defect ManagementAlternate block allocation Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Write Write Extend Defect Management This page is intentionally left blank Installation Requirements Mounting Requirements External dimensionsInstallation Requirements Mounting Requirements MountingMounting frame structure HDC Surface temperature check pointMPU Service clearance area Power Supply Requirements Current waveform +12 VDCAC noise filter recommended Connection Requirements Connector Connection Requirements10 SCA2 type connector Installation Installation Mode settings SettingSetting Loop ID setting Motor start modeMounting Drives Mounting procedures Dismounting Drives Installation Checking connection Checking the IDD connection a Checking the IDD connection B Formatting C141-E198 Setting parameters Awre ArreArre Awre PER Xffff DiscXxxx Read/write Diagnostics Self-diagnostics Self-diagnostic functionsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information Maintenance Information PrecautionsMaintenance requirements Maintenance Information Maintenance levels Revision numbers Revision label exampleIndicating revision numbers Tools and test equipment TestsTest flowchart Operation Check Initial seek operation check Diagnostic testOperation test Troubleshooting Procedures Troubleshooting with disk drive replacement in the fieldSystem-level field troubleshooting Troubleshooting at the repair site Disk drive troubleshootingTroubleshooting with parts replacement in the factory Finding possibly faulty partsError Analysis Information Collection Sense data Error Analysis Information Collection Sense Data AnalysisSense key, sense code, and subsense code LSB Error AnalysisILI SksvSense Data Analysis Definition of sense dataSense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-40-xx, 4-44-xx, and 4-C4-xxAppendix a Connector Signal Allocation Connector Signal Allocation Glossary Glossary Target TargAcronyms and Abbreviations Acronyms and Abbreviations RSVBcrc ECCMtbf Mttr Mode SELECT/MODEIndex PADC141-E198 IN-3 This page is intentionally left blank Fujitsu Canada INC This page is intentionally left blank READER’S Comment Form This page is intentionally left blank