6.1 Diagnostics

The IDD does not reply to the loop for up to 2 seconds after the initial self-diagnostics is started. After that, the IDD can accept the I/O operation request correctly, but the received command, except the executable commands under the not ready state (such as INQUIRY, START/STOP UNIT), is terminated with the CHECK CONDITION status (NOT READY [=2]/Logical unit is in process of becoming ready [=04-01] or Logical unit not ready, initializing command required [=04-02]) during the interval from the spindle motor becomes stable to the IDD becomes ready. The executable command under the not ready state is executed in parallel with the initial self-diagnostics, or is queued by the command queuing feature and is executed after completion of the initial self- diagnostics. When the command that comes under the exception condition of the command queuing is issued at that time, the IDD posts the BUSY status for the command. When the error is detected during the initial self-diagnostics, the CHECK CONDITION status is posted for all commands that were stacked during the initial self-diagnostics. For the command execution condition, refer to Section 1.4 and Subsection 1.7.4 in Fibre Channel Interface Specifications.

(2)Online self-diagnostics (SEND DIAGNOSTIC command)

The INIT can make the IDD execute self-diagnostics by issuing the SEND DIAGNOSTIC command.

The INIT specifies the execution of self-diagnostics by setting 1 for the SelfTest bit on the CDB in the SEND DIAGNOSTIC command and specifies the test contents with the UnitOfl bit.

When the UnitOfl bit on the CDB is set to 0, the IDD executes the hardware function test only once. When UnitOfl bit is set to 1, the IDD executes the hardware function test, seek (positioning) test, and data write/read test for the Internal test space only once.

a.Error recovery during self-diagnostics

During the self-diagnostics specified by the SEND DIAGNOSTIC command, when the recoverable error is detected during the seek or the write/read test, the IDD performs the error recovery according to the MODE SELECT parameter value (read/write error recovery parameter, additional error recovery parameter) which the INIT specifies at the time of issuing the SEND DIAGNOSTIC command.

PER

Operation of self-diagnostics

0The self-diagnostics continues when the error is recovered. The self- diagnostics terminates normally so far as the unrecoverable error is not detected.

1The self-diagnostics continues when the error is recovered. If the unrecoverable error is not detected, the consecutive tests are executed till last test but the self-diagnostics terminates with error. The error information indicates that of the last recovered error.

b.Reporting result of self-diagnostics and error indication

When all specified self-diagnostics terminate normally, the IDD posts the GOOD status for the SEND DIAGNOSTIC command.

When an error is detected in the self-diagnostics, the IDD terminates the SEND DIAGNOSTIC command with the CHECK CONDITION status.

C141-E198

6-3

Image 81
Contents MAS3735FC MAS3367FC Disk Drives PRODUCT/MAINTENANCE Manual For Safe Operation Revision History This page is intentionally left blank Overview of Manual PrefaceConventions for Alert Messages PrefaceC141-E198 Iii This page is intentionally left blank Important Alert Messages Important Alert ItemsImportant Alert Items C141-E198 Vii This page is intentionally left blank Manual Organization Product Maintenance ManualFibre Channel Physical and Signaling INTERFACE-2 FC-PH-2 Fibre Channel Physical and Signaling Interface FC-PHFibre Channel Arbitrated Loop FC-AL Fibre Channel Plotocol for Scsi SCSI-FCPContents Contents InstallationAppendix a Connector Signal Allocation Figures Tables This page is intentionally left blank General Description Standard Features Hardware Structure System ConfigurationGeneral Description Standard FeaturesStandard Features General Description FC model drives outer view Hardware StructureMAS3735FC MAS3367FC Disk/head configurationExample of FC-AL system configuration System ConfigurationGeneral Description Hardware Specifications Model name and order number Hardware SpecificationsModel names and order numbers MAS3735FCFunction specifications Specifications32/34 Meeprml FC-ALHardware Specifications Environmental specifications Environmental/power requirementsIops Reliability Error rateMTBF= Hardware Specifications This page is intentionally left blank Cylinder configuration Data Space Logical Data Block Addressing Defect ManagementData Space Data Format Zone layout and track capacity Data SpaceAlternate spare area Track format Data SpaceMsec Servo frame = 211 zone 0 ~ 266 zone Sector format Track skew/head skewData Format Format capacity Logical Data Block AddressingData Format Defect Management Defect Management Defect listAlternate block allocation Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Write Write Extend Defect Management This page is intentionally left blank Mounting Requirements External dimensions Installation RequirementsInstallation Requirements Mounting Mounting RequirementsMounting frame structure Surface temperature check point HDCMPU Service clearance area Current waveform +12 VDC Power Supply RequirementsAC noise filter recommended Connection Requirements Connection Requirements Connector10 SCA2 type connector Installation Installation Setting Loop ID setting SettingMode settings Motor start modeMounting Drives Mounting procedures Dismounting Drives Installation Checking connection Checking the IDD connection a Checking the IDD connection B Formatting C141-E198 Setting parameters Arre AwreArre Awre PER Disc XffffXxxx Read/write Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information Precautions Maintenance InformationMaintenance requirements Maintenance Information Maintenance levels Revision label example Revision numbersTests Indicating revision numbers Tools and test equipmentTest flowchart Diagnostic test Operation Check Initial seek operation checkOperation test Troubleshooting with disk drive replacement in the field Troubleshooting ProceduresSystem-level field troubleshooting Disk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting with parts replacement in the factoryError Analysis Information Collection Sense Data Analysis Error Analysis Information Collection Sense dataSense key, sense code, and subsense code ILI Error AnalysisLSB SksvDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-40-xx, 4-44-xx, and 4-C4-xx Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorAppendix a Connector Signal Allocation Connector Signal Allocation Glossary Target Targ GlossaryAcronyms and Abbreviations RSV Acronyms and AbbreviationsECC BcrcIndex Mode SELECT/MODEMtbf Mttr PADC141-E198 IN-3 This page is intentionally left blank Fujitsu Canada INC This page is intentionally left blank READER’S Comment Form This page is intentionally left blank