Fujitsu MAS3735FC, MAS3367FC manual READER’S Comment Form

Page 111

READER’S COMMENT FORM

Your comments or suggestions on this document are cordially solicited. For any comments and suggestions you may have, please complete and submit this form to your FUJITSU representative. The comments and suggestions will be used in planning future editions. Thank you for your cooperation.

Date issued:

 

Manual

MAS3735FC

name:

 

MAS3367FC

 

 

 

 

 

 

DISK DRIVES PRODUCT/MAINTENANCE

 

 

 

 

 

 

MANUAL

Name:

 

Manual

C141-E198-02EN

code:

 

 

Company or organization:

 

 

 

 

 

 

 

Address:

 

 

 

Comments:

Page

Line

Comments

 

 

 

 

 

 

 

 

Reply requested:

Yes

No

 

Please evaluate overall quality of this manual by marking (√ ) in the appropriate boxes.

 

 

Good Fair Poor

Good Fair Poor

Good Fair Poor

Organization:

Use of examples:

 

 

Legibility:

 

Accuracy:

Index coverage:

 

 

Handiness/Binding:

 

Clarity:

Cross referencing:

 

 

 

(Others):

 

Figures & tables:

General appearance:

 

 

 

 

 

Technical level:

Too high

Appropriate

 

Too low

 

Overall rating of

 

 

 

 

 

 

 

this publication:

Good

Fair

 

Poor

 

 

FOR FUJITSU USE

Overseas office:

 

Person in charge:

Note) Local representative should pass this form to the section in charge of distribution in FUJITSU.

Reply

By

FUJITSU LIMITED

Image 111
Contents MAS3735FC MAS3367FC Disk Drives PRODUCT/MAINTENANCE Manual For Safe Operation Revision History This page is intentionally left blank Overview of Manual PrefaceConventions for Alert Messages PrefaceC141-E198 Iii This page is intentionally left blank Important Alert Messages Important Alert ItemsImportant Alert Items C141-E198 Vii This page is intentionally left blank Manual Organization Product Maintenance ManualFibre Channel Plotocol for Scsi SCSI-FCP Fibre Channel Physical and Signaling Interface FC-PHFibre Channel Physical and Signaling INTERFACE-2 FC-PH-2 Fibre Channel Arbitrated Loop FC-ALContents Contents InstallationAppendix a Connector Signal Allocation Figures Tables This page is intentionally left blank General Description Standard Features Hardware Structure System ConfigurationGeneral Description Standard FeaturesStandard Features General Description FC model drives outer view Hardware StructureMAS3735FC MAS3367FC Disk/head configurationExample of FC-AL system configuration System ConfigurationGeneral Description MAS3735FC Hardware SpecificationsHardware Specifications Model name and order number Model names and order numbersFC-AL SpecificationsFunction specifications 32/34 MeeprmlHardware Specifications Environmental specifications Environmental/power requirementsIops Reliability Error rateMTBF= Hardware Specifications This page is intentionally left blank Cylinder configuration Data Space Logical Data Block Addressing Defect ManagementData Space Data Format Zone layout and track capacity Data SpaceAlternate spare area Track format Data SpaceMsec Servo frame = 211 zone 0 ~ 266 zone Sector format Track skew/head skewData Format Format capacity Logical Data Block AddressingData Format Defect Management Defect Management Defect listAlternate block allocation Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Write Write Extend Defect Management This page is intentionally left blank Mounting Requirements External dimensions Installation RequirementsInstallation Requirements Mounting Mounting RequirementsMounting frame structure Surface temperature check point HDCMPU Service clearance area Current waveform +12 VDC Power Supply RequirementsAC noise filter recommended Connection Requirements Connection Requirements Connector10 SCA2 type connector Installation Installation Motor start mode SettingSetting Loop ID setting Mode settingsMounting Drives Mounting procedures Dismounting Drives Installation Checking connection Checking the IDD connection a Checking the IDD connection B Formatting C141-E198 Setting parameters Arre AwreArre Awre PER Disc XffffXxxx Read/write Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information Precautions Maintenance InformationMaintenance requirements Maintenance Information Maintenance levels Revision label example Revision numbersTests Indicating revision numbers Tools and test equipmentTest flowchart Diagnostic test Operation Check Initial seek operation checkOperation test Troubleshooting with disk drive replacement in the field Troubleshooting ProceduresSystem-level field troubleshooting Disk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting with parts replacement in the factoryError Analysis Information Collection Sense Data Analysis Error Analysis Information Collection Sense dataSense key, sense code, and subsense code Sksv Error AnalysisILI LSBDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-40-xx, 4-44-xx, and 4-C4-xx Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorAppendix a Connector Signal Allocation Connector Signal Allocation Glossary Target Targ GlossaryAcronyms and Abbreviations RSV Acronyms and AbbreviationsECC BcrcPAD Mode SELECT/MODEIndex Mtbf MttrC141-E198 IN-3 This page is intentionally left blank Fujitsu Canada INC This page is intentionally left blank READER’S Comment Form This page is intentionally left blank