Fujitsu MAS3367FC, MAS3735FC manual System-level field troubleshooting

Page 92

Diagnostics and Maintenance

 

Table 6.2

System-level field troubleshooting

 

 

 

 

Item

 

 

Recommended work

 

 

 

DC power level

 

Check that the DC voltage is within the specified range (±5%).

 

 

Check that the +5 VDC value (pin of the interface connector) is 4.75 to

 

 

5.25 VDC.

 

 

Check that the +12 VDC supply (pin of the interface connector of disk

 

 

drive) is 11.4 to 12.6 VDC.

 

 

 

Electrical noise

 

Make sure the maximum ripple peak-to-peak value of +5 VDC is within

 

 

250 mV and +12 VDC is within 250 mV.

 

 

Make sure the high frequency noise (over 20 MHz) is less than

 

 

100 mVp-p.

 

 

 

Drive selection address

 

Check that the disk drive selection address is set correctly.

 

 

 

System cables

 

Check that all system cables are connected correctly.

 

 

 

System diagnostic test

 

When possible, execute the system level diagnostic routine as explained

 

 

in the host computer manual. This gives a detailed report of a possible

 

 

fault.

 

 

 

 

Intermittent or nonfatal errors

 

Check the AC voltage from the power supply. Check the DC voltage

 

 

level at the power connector for the disk drive.

 

 

If the AC voltage level is abnormal or there is a lot of electrical noise,

 

 

notify the user of the error.

 

 

If the DC voltage level is unstable, replace the power supply unit.

 

 

If possible, replace the disk drive. If replacing the disk drive does not

 

 

eliminate the error, the removed disk drive is probably not faulty. To

 

 

continue error analysis, refer to the hardware and software manuals

 

 

supplied with the system.

 

 

 

 

6-14

C141-E198

Image 92
Contents MAS3735FC MAS3367FC Disk Drives PRODUCT/MAINTENANCE Manual For Safe Operation Revision History This page is intentionally left blank Preface Overview of ManualPreface Conventions for Alert MessagesC141-E198 Iii This page is intentionally left blank Important Alert Items Important Alert MessagesImportant Alert Items C141-E198 Vii This page is intentionally left blank Maintenance Manual Manual Organization ProductFibre Channel Physical and Signaling Interface FC-PH Fibre Channel Physical and Signaling INTERFACE-2 FC-PH-2Fibre Channel Arbitrated Loop FC-AL Fibre Channel Plotocol for Scsi SCSI-FCPContents Installation ContentsAppendix a Connector Signal Allocation Figures Tables This page is intentionally left blank Standard Features Hardware Structure System Configuration General DescriptionStandard Features General DescriptionStandard Features General Description Hardware Structure FC model drives outer viewDisk/head configuration MAS3735FC MAS3367FCSystem Configuration Example of FC-AL system configurationGeneral Description Hardware Specifications Hardware Specifications Model name and order numberModel names and order numbers MAS3735FCSpecifications Function specifications32/34 Meeprml FC-ALHardware Specifications Iops Environmental specificationsEnvironmental/power requirements Error rate ReliabilityMTBF= Hardware Specifications This page is intentionally left blank Data Space Cylinder configurationData Space Logical Data Block Addressing Defect Management Data Format Data Space Zone layout and track capacityAlternate spare area Data Space Track formatMsec Servo frame = 211 zone 0 ~ 266 zone Track skew/head skew Sector formatData Format Logical Data Block Addressing Format capacityData Format Alternate block allocation Defect ManagementDefect Management Defect list Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Write Write Extend Defect Management This page is intentionally left blank Installation Requirements Mounting Requirements External dimensionsInstallation Requirements Mounting Requirements MountingMounting frame structure MPU Surface temperature check pointHDC Service clearance area Power Supply Requirements Current waveform +12 VDCAC noise filter recommended Connection Requirements Connector Connection Requirements10 SCA2 type connector Installation Installation Setting Setting Loop ID settingMode settings Motor start modeMounting Drives Mounting procedures Dismounting Drives Installation Checking connection Checking the IDD connection a Checking the IDD connection B Formatting C141-E198 Setting parameters Awre ArreArre Awre PER Xxxx DiscXffff Read/write Diagnostics Self-diagnostics Self-diagnostic functionsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information Maintenance Information PrecautionsMaintenance requirements Maintenance Information Maintenance levels Revision numbers Revision label exampleIndicating revision numbers Tools and test equipment TestsTest flowchart Operation test Diagnostic testOperation Check Initial seek operation check Troubleshooting Procedures Troubleshooting with disk drive replacement in the fieldSystem-level field troubleshooting Troubleshooting at the repair site Disk drive troubleshootingTroubleshooting with parts replacement in the factory Finding possibly faulty partsSense key, sense code, and subsense code Error Analysis Information Collection Sense Data AnalysisError Analysis Information Collection Sense data Error Analysis ILILSB SksvSense Data Analysis Definition of sense dataSense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-40-xx, 4-44-xx, and 4-C4-xxAppendix a Connector Signal Allocation Connector Signal Allocation Glossary Glossary Target TargAcronyms and Abbreviations Acronyms and Abbreviations RSVBcrc ECCMode SELECT/MODE IndexMtbf Mttr PADC141-E198 IN-3 This page is intentionally left blank Fujitsu Canada INC This page is intentionally left blank READER’S Comment Form This page is intentionally left blank