Table 6.1 Check items (continued)
Problem | Possible cause | Response | |
|
|
| |
The lamp does | The interface cables were not | Connect the interface cables correctly. | |
not light (ready) | connected correctly. |
| |
while the power |
|
| |
The terminator was not | Connect the terminator. | ||
indicator blinks. | |||
connected. |
| ||
|
| ||
|
|
| |
The check | The carrier fixing bracket | Remove the carrier fixing bracket as | |
indicator is on. | was not removed. | explained in Section 3.2, “Removing the | |
|
| Carrier Fixing Bracket.” | |
|
|
| |
| Turn the power off then on again. If the | ||
|
| check indicator turns on again, contact the | |
|
| sales person in charge or a Fujitsu service | |
|
| representative. | |
|
|
| |
"Please clean- | The mirror is dirty. | Clean the mirror as explained in Sec- | |
up!!" is dis- |
| tion 5.3.4. | |
played on the |
|
| |
operator panel |
|
| |
during the read |
|
| |
operation. |
|
| |
|
|
| |
"Please clean | The pick roller is dirty. | When the power is turned off, the mes- | |
| sage is cleared. | ||
displayed on the |
| Even if the message is displayed, the read | |
operator panel |
| operation can be continued. Clean the | |
during the read |
| pick roller after the read operation. | |
operation in the |
| (See Section 5.3.2.) | |
automatic |
|
| |
The unallowable document | If a document not meeting the scanner | ||
document | |||
was read in the automatic | specifications is read in the automatic | ||
feeder. | |||
document feeder. | document feeder, the document is not fed | ||
| |||
| (See Section 4.3.) | smoothly and an error message may be | |
|
| displayed. | |
|
| Read the document in the flat bed station. | |
|
|
| |
Paper double | Pad is dirty. | Clean the Pad. (See Section 5.3.2) | |
feed |
|
| |
|
|
| |
Miss pick | Pick rollers are dirty. | Clean the Pick rollers. (See Section 5.3.2) | |
|
|
| |
Paper jam | Some foreign particles are in | Clean the ADF (See Section 5.3.2) or | |
| ADF | remove any foreign particles. | |
|
|
|
6 – 2