Cisco Systems 124792, 124778, 159330 manual Removing the 1 RU DC Cable

Page 60

Chapter 3 Component Replacement

3.2.1 Replace the 1 RU Distribution Shelf

Figure 3-1 Removing the 1 RU DC Cable

124781

Step 5 Locate the distribution alarm cable at the rear of the 1RU DC Distribution Shelf.

Step 6 Remove the 10 pin Molex™ alarm cable by squeezing the top and pulling the cable away from the shelf (Figure 3-1#1).

Step 7 Locate the four 6AWG (16mm²) power cables provided at the rear of the 1RU Distribution Shelf.

Step 8 Remove the power cables by pulling them out and away from the 1RU Distribution Shelf (Figure 3-1#3).

Note Cover the connectors to insulate the live current on the lugs.

Step 9 Locate the ground cable attached to the #10 studs at the rear of the 1RU Distribution Shelf. Step 10 Using an 8mm socket or wrench remove the nuts and the ground cable (Figure 3-1#4). Step 11 Remove the four screws that mount the shelf to the cabinet/rack (Figure 3-2).

Cisco AC/DC Power System User Guide, R1.0

3-2

May 2006

 

 

Image 60
Contents Cisco AC/DC Power System User Guide Corporate HeadquartersCisco AC/DC Power System User Guide, Release N T E N T S System Operation Add Modules Contents Cisco AC/DC Power System User Guide, R1.0 Two-Inch Clearance Around Front Ventilation Opening Viii Supplied Materials for the System Shelf Tables Cisco AC/DC Power System User Guide, R1.0 Document Objectives AudienceDocument Organization Document Conventions Convention ApplicationWhere to Find Safety and Warning Information Obtaining DocumentationCisco.com Ordering DocumentationDocumentation Feedback Obtaining Technical AssistanceCisco Technical Support Website Submitting a Service Request Definitions of Service Request SeverityObtaining Additional Publications and Information Introduction System DescriptionSystem Shelf LCDRectifier Modules Introduction Rectifier ModulesGMT Fuses 4 1 RU Distribution ShelfSystem Configurations 1 RU Distribution ShelfGeneral Specifications From Wire Gauge AmpacityElectrical Value Status & Alarms Description Protection DescriptionMechanical Description Environment DescriptionSafety Recommendations Compliance DescriptionInstallation Warning Operating Temperature WarningsElectrical Safety Warnings Two-Inch Clearance Around Front Ventilation OpeningIntroduction Electrical Safety Warnings May Pre-Installation Ground SymbolTools Required Installation and Commissioning Checklist Installation MaterialsDescription Qty Use Install AC/DC Power System Components Install the System Shelf Cisco AC/DC Power System Front ViewInstalling the System Shelf Install the 1 RU Distribution Shelf 1 RU Distribution Cable DressingInstall the Communications Cabling Optional Install the DC Power Cabling Optional Install the Ground Cable Installing 1 RU DC CablingInstall the Cabinet/Rack Ground Install the 1 RU Distribution Shelf Ground Install AC Power Cables 11 Installing the 1 RU Distribution Shelf GroundSystem Installation Install AC Power Cables 12 Installing the AC Cable Shelf 13 Routing AC Cables Install the Rectifiers 14 Installing a Rectifier Install Circuit Breakers 15 Removing a Rectifier Blank Faceplate16 Circuit Breaker On/Off Positions 18 Installing a Circuit Breaker System SizeInstall the Alarm Cable 19 Removing the Controller Faceplate Without LCD Alarm Designation Jumper System withInstall Load-and-Return Connections Wire Gauge Stranded ApplicationsInstall GMT Fuse Connections Install 1 RU Distribution Shelf Load Connections 23 Installing GMT CablingA2 A1 Return Load System Upgrades Small to Medium System UpgradeMedium to Large System Upgrade Small to Large System UpgradeMay Safety Component ReplacementReplace the 1 RU Distribution Shelf Removing the 1 RU DC Cable Replace the Controller Tray Removing the 1 RU Distribution ShelfRemoving the Controller Faceplate J15 terminal block J14/J13 terminal blocks Replace Circuit Breakers Circuit Breaker On/Off PositionsRemoving the 1 RU Distribution Shelf Faceplate Replace a Rectifier Removing a Circuit BreakerRemoving a Rectifier Replace GMT Fuses 10 Removing a GMT FuseSystem Commissioning General InformationAlarm Interface Board and Connections Basic Controller FunctionsRemove Modules May System Troubleshooting Tripped breaker Fuse blown Module Locations Page System Parts List Description Part NumberPage Translated Safety Warnings Statement 12-Power Supply Disconnection WarningAppendix a Translated Safety Warnings Statement 43-Jewelry Removal Warning Appendix a Translated Safety Warnings Appendix a Translated Safety Warnings Appendix a Translated Safety Warnings Appendix a Translated Safety Warnings Page Statement 1017-Restricted Area May Statement 1024-Ground Conductor Appendix a Translated Safety Warnings Statement 1030-Equipment Installation Statement 1033-SELV-IEC 60950 DC Power Supply Statement 1047-Overheating Prevention Appendix a Translated Safety Warnings Appendix a Translated Safety Warnings