Cisco Systems (VIP6-80) manual Show controllers command

Page 30

To display hardware information about a specific interface on a VIP6-80 port adapter, append the type argument (fastethernet, hssi, and so forth) and the interface address argument (interface-processor-slot-number/port-adapter-slot-number/interface-port-number)to the

show controllers command.

Following is an example of the syntax for this command for the interface on a PA-2FE port adapter installed in port adapter slot 1 of a VIP6-80 installed in interface processor slot 1 of a Cisco 7000 series or Cisco 7500 series router:

Router# show controllers fastethernet 1/1/0

To display the configuration of the system hardware (the number of each interface processor type installed), the software version, the names and sources of configuration files, and the boot images, use the show version (or show hardware) command.

Following is an example of the show version command used with a Cisco 7500 series router:

Router# show version

Cisco Internetwork Operating System Software

IOS (tm) RSP Software (RSP-JSV-M), Version 12.0(10r)S1, EARLY DEPLOYMENT

MAINTENANCE INTERIM SOFTWARE

TAC Support:http://www.cisco.com/cgi-bin/ibld/view.pl?i=support

Copyright (c) 1986-2002 by cisco Systems, Inc.

Compiled Fri 22-Mar-02 16:27 by ninahung

Image text-base:0x60010950, data-base:0x612A2000

ROM:System Bootstrap, Version 12.0(10r)S1, RELEASE SOFTWARE (fc1)

UUT uptime is 2 minutes

System returned to ROM by reload at 15:33:45 UTC Tue Mar 5 2002

System image file is "disk0:rsp-pv-mz.vip6-3.022802"

cisco RSP4+ (R5000) processor with 65536K/2072K bytes of memory. R5000 CPU at 200Mhz, Implementation 35, Rev 2.1, 512KB L2 Cache Last reset from power-on

G.703/E1 software, Version 1.0. G.703/JT2 software, Version 1.0.

X.25 software, Version 3.0.0.

1 VIP6 RM7000B controller (2 FastEthernet).

1GEIP controller (1 GigabitEthernet).

2FastEthernet/IEEE 802.3 interface(s)

1 Gigabit Ethernet/IEEE 802.3 interface(s)

123K bytes of non-volatile configuration memory.

47040K bytes of ATA PCMCIA card at slot 0 (Sector size 512 bytes). 16384K bytes of Flash internal SIMM (Sector size 256K).

No slave installed in slot 7. Configuration register is 0x0

WARNING:Chassis Interface not present

To determine specific hardware configuration information about a VIP6-80 installed in your system (including the amount of installed CPU and packet memory), use the show diag slot command.

Specific information is displayed, as shown in the following example of a VIP6-80 with a PA-2FE port adapter; the VIP6-80 is installed in interface processor slot 4:

 

 

 

Router#

show diag 4

 

 

 

Slot 4:

 

 

 

 

 

 

Physical slot 4, ~physical slot 0xB, logical slot 4, CBus 0

 

 

 

 

Microcode Status 0x4

 

 

 

 

Master Enable, LED, WCS Loaded

 

 

 

 

Board is analyzed

 

 

 

 

Pending I/O Status:None

 

 

 

Versatile Interface Processor (VIP6-80) Installation and Configuration Guide

 

 

 

 

 

 

 

 

 

 

30

 

 

OL-5078-01

 

 

 

 

 

Image 30
Contents Contents IntroductionRelated Documentation Product Description VIP6-80 Features CPU Memory ComponentsMicrocode LEDsJumpers ROM MonitorPort Adapter Slots PA-2FE-TXPA-2FE-FX Specifications System SoftwareSoftware Requirements Installation PrerequisitesTraffic Management Hardware RequirementsAgency Approvals Safety Guidelines Microcode RequirementsTools and Parts Required Safety Warnings Telephone Wiring Guidelines Electrical Equipment GuidelinesPreventing Electrostatic Discharge Damage Guidelines for Removal and Installation Handling Interface Processors-Vertical Orientation Shown Bottom ejector lever Processor module slot Module Removing a VIP6-80 Removing and Installing Port Adapters Single-Width Port Adapter Handling a Port AdapterRemoving and Installing a Single-Width Port Adapter Dual-Width Port Adapter Location of VIP6-80 Slot Divider and ScrewsRemoving and Installing a Dual-Width Port Adapter Installing a VIP6-80 Connecting Cables to the Port AdapterPerforming a Basic Configuration Removal Checking the VIP6-80 InstallationVerifying the Installation InsertionPage Using show Commands to Verify the VIP6-80 Status Using show Commands to Display Interface Information Router# show controllers cbusShow controllers command Using the ping Command to Verify Network Connectivity RMAMaintenance Procedures Single Line Card ReloadUpgrading VIP6-80 Memory Product Description Removing Sdram DIMMs Opening the Dimm Socket TabsInstalling Sdram DIMMs Inserting the DimmTroubleshooting Checking the VIP6-80 Memory UpgradeDocumentation CD-ROM Obtaining DocumentationCisco.com Ordering DocumentationObtaining Technical Assistance Documentation FeedbackCisco TAC Website Opening a TAC Case Obtaining Additional Publications and Information TAC Case Priority DefinitionsOL-5078-01