Configuring the HSSI Interfaces
Use the show controllers cbus command to display all the current interface processors and their interfaces. Following is an example of the show controller cbus command that shows the HSSI port 1/0/0 on a
Router# show controllers cbus
(additional displayed text omitted from this example)
slot1: VIP2, hw 2.3, sw 21.40, ccb 5800FF40, cmdq 48000090, vps 8192 software loaded from system
IOS (tm) VIP Software
received clockrate 51838976
gfreeq 48000160, lfreeq 48000200 (4480 bytes), throttled 0 rxlo 4, rxhi 258, rxcurr 0, maxrxcurr 0
txq 48001A80, txacc 48001A82 (value 129), txlimit 129
(additional displayed text omitted from this example)
Note For complete VIP2 command descriptions and examples, refer to the documentation resources listed in the “If You Need More Information” section on page vii.
Proceed to the section “Using the ping Command” to verify that each interface port is functioning properly.
Catalyst RSM/VIP2 show Commands
Caution If you are using the HSSI
Caution You can only have two HSSI
Catalyst
Following is an example of how the show interfaces