Chapter 4 Turn Up Node
Step 6 Review the node information. If you need to make corrections, repeat Steps 3 through 5 to enter the corrections. If the information is correct, continue with the
Stop. You have completed this procedure.
NTP-D279 Set Power Monitor Thresholds
Purpose | This procedure provisions extreme high, high, extreme low, and low input |
| battery power thresholds within a |
| environment. When the thresholds are crossed, the TCC2 generates |
| warning alarms in CTC. |
Tools/Equipment | None |
Prerequisite Procedures | |
Required/As Needed | Required |
Onsite/Remote | Onsite or remote |
Security Level | Provisioning or higher |
Step 1 | Complete the |
| already logged in, continue with Step 2. |
Step 2 | In node view, click the Provisioning > General > Power Monitor tabs. |
Step 3 To change the extreme low battery voltage threshold in 0.5 VDC increments, choose a voltage from the ELWBATVGVdc
Step 4 To change the low battery voltage threshold in 0.5 VDC increments, choose a voltage from the LWBATVGVdc
Step 5 To change the high battery voltage threshold in 0.5 VDC increments, choose a voltage from the HIBATVGVdc
Step 6 To change the extreme high battery voltage threshold in 0.5 VDC increments, choose a voltage from the EHIBATVGVdc
Step 7 Click Apply.
Stop. You have completed this procedure.
Cisco ONS 15454 SDH Procedure Guide, R4.6