EMULEX MODEL 375 SAN STORAGE SWITCH | CHAPTER 3: SWITCH MANAGEMENT |
USER’S GUIDE |
Adjusting the Switch Thresholds
The Switch Thresholds page displays a variety of switch threshold settings.
Setting | Description |
|
|
Ordered Set Error Threshold | The maximum number of OS errors allowed in a |
| interval before a port is bypassed. Setting this value to "0" returns |
| it to the factory default setting. |
| This setting is activated on the Port Smart Settings page. |
|
|
CRC Error Threshold | The maximum number of CRC errors allowed in a |
| interval before a port is bypassed. Setting this value to "0" returns |
| it to the factory default setting. |
| This setting is activated on the Port Smart Settings page. |
|
|
Bad Zone Recovery Hold Time | The amount of time that the switch keeps the ports in bypass |
(measured in | mode before attempting to |
| This setting is activated on the Advanced Functions |
| Zoning page. |
|
|
Bad Zone Recovery Delay | The amount of time that the switch waits after a zone goes down |
Time | before attempting to recover the zone. |
(measured in seconds) | This setting is activated on the Advanced Functions |
| Zoning page. |
|
|
Port Utilization Interval | The length of time between readings of the current port’s |
(measured in seconds) | utilization. |
|
|
To view the current threshold settings:
Click Advanced Functions > Thresholds > Switch.
The Switch Thresholds page appears.
Figure 3-7: Switch Thresholds page
To change switch thresholds or time intervals:
1.Enter the new value in the appropriate text box. The valid range is displayed next to the text box.
2.Click Submit.
The new value is set.