EMULEX MODEL 375 SAN STORAGE SWITCH | APPENDIX C: EVENT MESSAGES |
USER’S GUIDE |
APPENDIX C Event Messages
The event messages for the switch are listed below. For explanations, contact a customer service representative. The message’s applicable severity level as defined below is also provided.
Severity | Severity | Description | |
Level | |||
|
| ||
|
|
| |
1 | EMERG | Immediate action required; system failing | |
|
|
| |
2 | ALERT | Unrecoverable condition reported; major event in progress | |
|
|
| |
3 | CRIT | Event failed with possible loss of integrity | |
|
|
| |
4 | ERR | Condition failed; action required | |
|
|
| |
5 | WRN | Failed event occurred; no action required | |
|
|
| |
6 | NOTIFY | Configuration error or abnormal event occurred; no action required | |
|
|
| |
7 | INFO | Event occurred; no action required | |
|
|
|
These severity levels can be used to designate which events trigger trap messages. Use the Command Line Interface (CLI) to designate the minimum severity level of events to be logged in the Event Log and at which severity level to illuminate the switch’s Fault LED.
| Event | Event Message | Severity |
|
|
|
|
|
|
| 1 | Message log cleared | INFO |
|
|
|
|
|
|
| 5 | Power Supply # Failed | ALERT |
|
|
|
|
|
|
| 6 | Power Supply # Online | NOTIFY |
|
|
|
|
|
|
| 7 | Power Supply # Removed | ALERT |
|
|
|
|
|
|
| 8 | Power Supply # Inserted | NOTIFY |
|
|
|
|
|
|
| 9 | Fan has stopped | EMERG |
|
|
|
|
|
|
| 10 | Fan has returned | ALERT |
|
|
|
|
|
|
| 19 | Temperatures over limit | ALERT |
|
|
|
|
|
|
| 20 | Temperature OK | INFO |
|
|
|
|
|
|
| 50 | SPF Overvoltage | EMERG |
|
|
|
|
|
|
| 54 | SOC has detected a CRC error in the EEPROM | NOTIFY |
|
|
|
|
|
|
| 70 | PORT # bypassed | NOTIFY |
|
|
|
|
|
|
| 71 | PORT # inserted | NOTIFY |
|
|
|
|
|
|
| 72 | Transceiver detected at port # | NOTIFY |
|
|
|
|
|
|
| 73 | Transceiver removed at port # | NOTIFY |
|
|
|
|
|
|
| 74 | SEOC occurred on PORT # | NOTIFY |
|
|
|
|
|
|
| 75 | Port exceeded OS threshold | NOTIFY |
|
|
|
|
|
|
| 76 | Port exceeded CRC threshold | NOTIFY |
|
|
|
|
|
|
| 77 | Loop UP on Port # | NOTIFY |
|
|
|
|
|
|
| 78 | Loop DOWN on Port # | NOTIFY |
|
|
|
|
|
|
| 79 | PORT received a LIP(F8) | WRN |
|
|
|
|
|
|
| 80 | PORT CRC Error detected in frame | WRN |
|
|
|
|
|
|
| 81 | PORT did not receive LIPF7) within timeout | WRN |
|
|
|
|
|
|
|
|
|
|
|
|
| EMULEX CORPORATION | 68 | |
|