EMULEX MODEL 375 SAN STORAGE SWITCH | CHAPTER 4: TECHNICAL REFERENCE |
USER’S GUIDE |
DEFAULT SMART SETTING ATTRIBUTES
| Initiator or Target | Initiator with Stealth | Target with Stealth | Fabric Connection | Tree Cascade | String Cascade | String Cascade | String Cascade | String Cascade | |
|
|
|
|
|
|
|
|
|
| |
Smart Setting | Initiator or | Initiator | Target | Fabric | Tree | String | String | String | String | |
Name | Target | with | with | Connection | Cascade | Cascade | Cascade | Cascade | Cascade- | |
|
| Stealth | Stealth |
|
| |||||
|
|
|
|
|
|
|
|
|
| |
Smart Setting | Initiator or | Initiator or | Initiator or | Tree | Tree | String | String | String | String | |
Type | Target | Target | Target | Cascade | Cascade | Cascade | Cascade | Cascade | Cascade | |
| Port | Port | Port |
|
| 1 | 2 | 3 | 4 |
|
|
|
|
|
|
|
|
|
|
| |
Smart | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | |
Insertion |
|
|
|
|
|
|
|
|
|
|
Policy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Port Test | Enabled | Enabled | Enabled | Disabled | Disabled | Disabled | Disabled | Disabled | Disabled | |
Before Insert |
|
|
|
|
|
|
|
|
|
|
Policy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Stealth | Off: No | Initiator: | Target: | Off: No | Switch- | Switch- | Switch- | Switch- | Switch- | |
Intelligent | Change | Only | Only | Change | Switch: | Switch: | Switch: | Switch: | Switch: | |
Change | Protection | Receive | Send | Protection | Send and | Send and | Send and | Send and | Send and | |
Manager |
| Changes | Changes |
| Receive | Receive | Receive | Receive | Receive | |
|
|
|
| Changes | Changes | Changes | Changes | Changes | ||
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| |
Change | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | |
Notification on |
|
|
|
|
|
|
|
|
|
|
Insertion |
|
|
|
|
|
|
|
|
|
|
Policy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Change | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | |
Notification on |
|
|
|
|
|
|
|
|
|
|
Removal |
|
|
|
|
|
|
|
|
|
|
Policy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Bad Device | Disabled | Enabled | Disabled | Disabled | Disabled | Disabled | Disabled | Disabled | Disabled | |
Recovery |
|
|
|
|
|
|
|
|
|
|
Policy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Clear on Stall | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | |
Policy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Bypass on No | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | |
Activity Policy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Bypass on OS | Disabled | Disabled | Disabled | Disabled | Disabled | Disabled | Disabled | Disabled | Disabled | |
Error Policy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Bypass on | Disabled | Disabled | Disabled | Disabled | Disabled | Disabled | Disabled | Disabled | Disabled | |
CRC Error |
|
|
|
|
|
|
|
|
|
|
Policy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Port Control | Auto | Auto | Auto | Auto | Auto | Auto | Auto | Auto | Auto | |
|
|
|
|
|
|
|
|
|
| |
Bypass on | Disabled | Disabled | Disabled | Disabled | Disabled | Dis- | Dis- | Dis- | Dis- | |
Clock Delta |
|
|
|
|
| abled | abled | abled | abled | |
Policy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| EMULEX CORPORATION |
|
|
| 61 |
|
PART NUMBER